NEON CLASSIC
| ELECTRICAL AND PHYSICAL INSTALLATION GUIDE
–
LED Neon must always be used in conjunction with a
–
Check the polarity of the connector before inserting the front
connector and switching on the mains power.
–
To minimise voltage drop and ensure consistent light output,
position the power supply near to the power feed end of the
LED Neon, and keep the line as short as possible
–
Ensure your maximum run per power feed adheres to the
–
Ensure to add 20% buffer when selecting a power supply
–
Before making any cuts, installation, maintenance, or
connection, be sure the mains power is disconnected.
–
If essential; cut and connect LED Neon correctly. Any
incorrect operation can cause damage.
–
All connector joints must be connected correctly to
achieve connector IP rating.
WHITE / SINGLE COLOUR
WIRING DIAGRAMS
RGBW
RGB
POWER SUPPLY
RGB CONTROL
green wire: “G” terminal (-)
blue wire: “B” terminal (-)
yellow wire: +
red wire: “R” terminal (-)
24V DC
TUNEABLE WHITE
POWER SUPPLY
2-CHANNEL
CONTROL
black wire: Cool White connection (-)
red wire: +
yellow wire: Warm White connection (-)
24V DC
POWER SUPPLY
RGBW CONTROL
green wire: “G” terminal (-)
blue wire: “B” terminal (-)
white wire: “W” terminal (-)
yellow wire: +
red wire: “R” terminal (-)
24V DC
DYNAMIC RGB ‘CHASING’
POWER SUPPLY
DIMMER
optional
black wire: -
red wire: +
24V DC
DMX OPTION AVAILABLE
black wire: “GND”, Cathode (-) terminal
red wire: “VCC”, Anode (+) terminal
yellow wire: “Signal” terminal
POWER SUPPLY
INDEPENDENT
SPI CONTROL
24V DC
M ITNO1230001067-CL-HB/16/12/19/REV.0