•  The 2-Way Dimmers use standard 3-core connecting cables (or 3 core 
plus earth); however, because they are electronic dimmers, they utilise one 
of the cores as a signal cable (‘S’) running between the Dimmers (as shown 
on the diagram). 

This is low voltage only and should not be connected to 

230V mains

; serious damage will occur. 

•  Up to six 2-Way Dimmers (six gangs) can be connected to a standard  
LightwaveRF Dimmer Switch. Each 2-Way can be connected directly to the 
standard Dimmer, or connected to each other in a ‘daisy-chain’. This 
provides an alternative to using intermediate switches (maximum cable 
length of 100m). 

VERY IMPORTANT 

•  A LightwaveRF 2-Way Dimmer needs to be used in conjunction with a 
standard LightwaveRF Dimmer to perform 2-Way Switching. 

The

 

LightwaveRF 2-Way Dimmer cannot

 

be used in conjunction with a 

standard lightswitch. 

This will cause damage to the Dimmer.

• 

Never install and run power to a 2-Way Dimmer before first installing and 

connecting the corresponding standard LightwaveRF Dimmer. Serious 
damage could be caused to the unit. 

Installation

Содержание LW450 Connect Series

Страница 1: ...Connect Series www lightwaverf house 2 Way Dimmer 1 Gang Model No LW450 Instruction Manual Version 2 1...

Страница 2: ...99 5 EC R TTE Directive 93 68 EEC CE Marking Directive Standards Applied in order to verify compliance Safety BS EN 60730 1 2011 Health R TTE EN 301 489 1 V1 9 2 2011 09 EN 301 489 3 V1 4 1 2002 08 EN...

Страница 3: ...he electricity supply You will also need suitable electrical screwdrivers How do I get started Please refer to the following installation and setup instructions This will guide you step by step throug...

Страница 4: ...lluminated the dimmer is on Overview IMPORTANT All LightwaveRF products can be legally DIY installed in your own home however if in doubt always consult a qualified electrician or heating engineer It...

Страница 5: ...live out Screw mounting hole Live in 2 Way switching connection IMPORTANT If conducting an insulation resistance test all LightwaveRF products must be disconnected from the mains or damage will occur...

Страница 6: ...e connected directly to the standard Dimmer or connected to each other in a daisy chain This provides an alternative to using intermediate switches maximum cable length of 100m VERY IMPORTANT A Lightw...

Страница 7: ...be useful at this point to mark out or take a photograph of the connections to the existing switch so that the correct wires can easily be transferred to the new dimmer Some existing wiring configurat...

Страница 8: ...s neutral wire to be connected they only require live in and switched live out 7 Screw the dimmer switch to the mounting box and ensure that the screws are sufficiently tight to support the product bu...

Страница 9: ...ONLY be connected to the wire running to the other dimmer NOT live mains this will cause irreparable damage 3 or 4 core cable From lighting circuit Live Live Earth Switched live Signal cable Switched...

Страница 10: ...e used solely to switch between the on and off states without dimming This is because the technology used in an electronic dimmer is fundamentally different to that of a simple on off switch and requi...

Страница 11: ...verf house for further guidance and information Standard mains voltage incandescent low energy incandescent lighting min 20W max 250W GU10 and equivalent HI spot mains halogen lamps Dimmable electroni...

Страница 12: ...switch the dimmer off amber LED indicator will illuminate Press and hold to lower the light level Manual operation Manual dimming NOTE When the on button is tapped to turn on the dimmer the light leve...

Страница 13: ...mistake is to reverse the live and switched live connections Remember the signal terminal must NOT be connected to 230V mains If these measures fail contact technical support via www Lightwaverf com...

Страница 14: ...ponding standard LightwaveRF dimmer via the connected signal wire The standard LightwaveRF dimmer can be linked to a controller and passes on commands to the 2 Way Dimmer automatically Problem The dim...

Страница 15: ...Yes LightwaveRF is fully legal for you to install in your own home Q Is there a maximum number of lamps I can control with the dimmer A You can control any number of lamps bulbs as long as they do no...

Страница 16: ...mmers are not designed to have their switch modules separated and interchanged disconnecting and removing Dimmer Modules will invalidate the warranty Q What Happens after a power cut A Standard Lightw...

Страница 17: ...rating 220 240V 50Hz Back Box Depth 35mm min Earthing Requirement Not essential double insulated Standby Energy Use Less than 1W Wiring Neutral wire NOT required Warranty 2 year standard warranty Tech...

Страница 18: ...Version 2 1 2 Quadrant Park Mundells Welwyn Garden City Herts AL7 1FS 01707 386035 www lightwaverf house...

Отзывы: