background image

Setup

Device Setup

NOTE:

 Reliable range of remote operation is around 15 metres indoors and 

up to 100m outdoors (using a Lightwave Link). This figure may vary 
depending upon the environment; very thick walls, bodies of water or large 
metal objects may interfere with radio range.

If the distance between the transmitter and receiver is too great to achieve 
reliable operation, the LightwaveRF Signal Booster may be used in 
conjunction with this product to increase the range.

Clearing the memory (will remove all linked controllers):

1.

 On the gang to be cleared, Press and 

hold down both the ‘on’ and ‘off’ 
buttons until the blue and amber LEDs 
flash alternately then release. The 
dimmer switch is now in 

linking mode

.

2.

 On the dimmer switch, press and hold 

down the ‘off’ button again until the 
blue and amber LEDs flash 
simultaneously, then tap (don’t hold) 
the ‘off’ button a further time; the amber 
LED will flash to confirm that the 

Содержание JSJSLW420

Страница 1: ...Connect Series www lightwaverf com Dimmer Switch 2 Gang Model No JSJSLW420 Instruction Manual Version 2 ...

Страница 2: ...ve 1999 5 EC R TTE Directive 93 68 EEC CE Marking Directive Standards Applied in order to verify compliance Safety BS EN 60730 1 2011 Health R TTE EN 301 489 1 V1 9 2 2011 09 EN 301 489 3 V1 4 1 2002 08 EN 300 220 1 V2 1 1 2006 EN 300 220 2 V2 1 2 2007 EMC EN 301 489 1 V1 9 2 2011 09 EN 301 489 3 V1 4 1 2002 08 EN 55022 2010 EN 61000 3 2 2006 A1 2009 A2 2009 Class A EN 61000 3 3 2008 EN61000 4 2 2...

Страница 3: ...nderstand how to safely turn off the electricity supply You will also need suitable electrical screwdrivers Please refer to the following installation and setup instructions This will guide you step by step through the installation and setup process Help video further guidance For additional guidance and to watch a video that will help guide you through the installation process please visit the su...

Страница 4: ...illuminated Dimmer is on Overview Installation IMPORTANT All LightwaveRF products can be legally DIY installed in your own home however if in doubt always consult a qualified electrician or heating engineer It is important to install this product in accordance with the following instructions Failure to do so may void your warranty ...

Страница 5: ...e live out Screw mounting hole Live in 2 Way switching connection Installation IMPORTANT If conducting an insulation resistance test all LightwaveRF products must be disconnected from the mains or damage will occur ...

Страница 6: ...h if applicable It may be useful at this point to mark out or take a photograph of the connections to the existing switch so that the correct wires can easily be transferred to the new dimmer Some existing wiring configurations can be complex so take care 4 Gently remove the dimmer faceplate by inserting a screwdriver into one of the bottom slots and lifting away from the unit as shown ...

Страница 7: ...require a mains neutral wire to be connected they only require live in and switched live out 7 Screw the dimmer switch to the mounting box and ensure that the screws are sufficiently tight to support the product but do not over tighten as this may cause the chassis to bend Ensure that the plastic spacer is correctly aligned and that no wires are trapped between the dimmer switch and the back box 6...

Страница 8: ... terminal in back box can be capped off instead if no terminal present Live wire In This should be brown or red in colour Switched live wire out This should be blue or black in colour The switched live may be marked by brown red tape to emphasise that it is not a neutral wire NOTE Wiring shown for one of two gangs Please repeat for other gang ...

Страница 9: ...st 30cm apart in order to prevent the risk of any radio conflict that could disrupt remote operation Suitable lamps must be used with the dimmer or it will not function correctly See next section for compatibility information Important things to consider In a multigang dimmer to be able to operate any gang mains electricity must always be connected to all of the dimmer terminals ...

Страница 10: ...ly and should not be connected to 230V mains Important Never install and run power to a LightwaveRF 2 way dimmer switch before first installing and connecting the counterpart standard LightwaveRF dimmer Serious damage could be caused to the unit Connecting to a 2 Way Dimmer Any LightwaveRF dimmer switch and any gang in a multigang dimmer can be used in conjunction with a LightwaveRF 2 way dimmer t...

Страница 11: ...gnal cable input marked S must ONLY be connected to the wire running to the other dimmer NOT live mains this will cause irreparable damage 3 Core Cable From Lighting Circuit Live Live Earth Switched Live Signal Cable Switched Live ...

Страница 12: ...lamps see www lightwaverf house for further guidance and information Standard mains voltage incandescent low energy incandescent lighting min 20W max 250W GU10 and equivalent HI spot mains halogen lamps Dimmable electronic low voltage transformers 20W 250W max Inductive transformers 40 170VA max LightwaveRF dimmers are NOT compatible with the following Wirewound transformers generally older style ...

Страница 13: ...tly at high or low brightness levels especially if there is only a modest overall circuit load under 10W Stability can be achieved by a very slight adjustment to the dimming range of the LightwaveRF Dimmer The default setting smallest dimming range is the most stable for LEDs If the LEDs perform normally at this setting most cases then the range can be increased if desired using the following meth...

Страница 14: ...going until flicker is observed At this point return to the previous stable increment optimum level by pressing the on button Dimming Range Setup allows the dimmer s range to be adjusted to one of five presets If the dimmable LED lamps on the circuit perform properly at the initial setting smallest range then the range can be increased one stage at a time until flickering if any is observed The op...

Страница 15: ...uction in light output when using incandescent lamps bulbs In the vast majority of cases this should not be noticeable as the drop is very small ONLY dimmable lamps can be used even if the dimmers are used solely to switch between the on and off states without dimming This is because the technology used in an electronic dimmer is fundamentally different to that of a simple on off switch and requir...

Страница 16: ...m button once to switch the dimmer off amber LED indicator will illuminate Press and hold to lower the light level Manual operation Manual dimming NOTE When the on button is tapped to turn on the dimmer the light level will return to that at which it was last at before the dimmer was turned off The on or off buttons can then be pressed and held to customise the light level ...

Страница 17: ...the Lightwave Link this will always count as ONE controller and take up one memory slot even if you are using multiple smartphones tablets 1 On the dimmer switch press and hold down both the on and off buttons on either gang until the blue and amber LEDs flash alternately then release them The dimmer switch is now in linking mode 2 Using the LightwaveRF App press the connect button the App instruc...

Страница 18: ...existing remotes is first unpaired see below 1 On the dimmer switch press and hold down both the off and on buttons until the blue and amber LEDs flash alternately then release them The dimmer switch is now in linking mode 2 Using the LightwaveRF Smartphone App enter the edit menu and press the delete button next to the relevant device the App instructions will guide you through this If using anot...

Страница 19: ...able operation the LightwaveRF Signal Booster may be used in conjunction with this product to increase the range Clearing the memory will remove all linked controllers 1 On the gang to be cleared Press and hold down both the on and off buttons until the blue and amber LEDs flash alternately then release The dimmer switch is now in linking mode 2 On the dimmer switch press and hold down the off but...

Страница 20: ...ler once to switch the dimmer on blue LED indicator will illuminate Use the slider to raise or lower the light level or press and hold the on or off button on any other LightwaveRF controller Press the off button on the App or other LightwaveRF controller once to switch the dimmer off amber LED indicator will illuminate Remote operation ...

Страница 21: ...immer is signified by a slow flashing amber LED To lock unlock the dimmer press the unlock button on the Smartphone App or Socket Locker If the Socket locker is misplaced the dimmers can be reset by turning of mains power to the circuit for a period of 30 seconds Flashing blue amber alternately Socket in Linking Mode Quickly flashing blue Socket successfully linked Quickly flashing amber Socket un...

Страница 22: ...the Dimmer automatically and turns the light on So when one of the kids needs to use the bathroom in the middle of the night the path is safely lit for them The light is then set to turn off once no movement has been detected for a period of time So when the little one is safely back in bed the sensor will turn off that light that is always normally left on Creative Ideas for Lightwave Dimmers ...

Страница 23: ... a group The Mood Controller allows you to set and recall your own favourite lighting scenes at the touch of a button You can dim all the lights for watching a movie or create a relaxed mood for entertaining guests At the end of the evening press the all off button to turn off all lights and lamps Adding the Lightwave Link allows scene lighting to be controlled via a smartphone Creative Ideas for ...

Страница 24: ... lamps plugged into Lightwave Power Sockets or Plug in Sockets Via the Lightwave Link every light can be controlled using a smartphone wherever you are So when you re away on holiday you can turn on lights to make it look like someone s home You can even set them to come on automatically at different times each evening enough to fool even the most watchful of intruders Creative Ideas for Lightwave...

Страница 25: ...are attached to the correct terminals a common mistake is to reverse these connections If these measures fail contact technical support via www lightwaverf house Problem The switch is powered amber or blue LEDs on but it will not link to a LightwaveRF handset or controller Solution Check the controller battery strength if the battery strength is low it will not produce enough power to drive the RF...

Страница 26: ...odies of water in the path of the transmission If the problem persists try moving the controller Link closer to the dimmer or consider using a LightwaveRF Signal Booster to extend the range by relaying the signal between controller and dimmer Problem The dimmer keeps turning off automatically wont turn off and displays flashing amber blue lights Solution The dimmer is locked This may have been don...

Страница 27: ...using over 35mm deep Q Is it legal for me to to install the dimmer A Yes it is fully legal to install LightwaveRF in your own home Q Is there a maximum number of bulbs I can control with the dimmer A You can control any number of bulbs as long as they do not exceed the maximum loading in total Note Max load differs for LED incandescent Q How many devices can I have on the LightwaveRF system A Each...

Страница 28: ...o have their switch modules separated and interchanged disconnecting and removing dimmer modules will invalidate the warranty Q Can I expect a drop in light output with a LightwaveRF dimmer A LightwaveRF dimmers utilise a tiny amount of power to drive the electronics that operate the RF radio and dimming components As a result it is normal to experience a 5 10 reduction in light output when using ...

Страница 29: ...220 240V 50Hz Output rating 3W 250W max per gang Incandescent Load 20W min 250W max per gang Back Box Depth 35mm min Earthing Requirement Not essential double insulated Standby Energy Use Less than 1W per gang Wiring Neutral wire NOT required Warranty 2 year standard warranty ...

Страница 30: ...www lightwaverf com Innovation Birmingham Campus Faraday Wharf Holt Street Birmingham B7 4BB 01707 386035 Version 2 ...

Отзывы: