![Lightware SF40/C Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/lightware/sf40-c/sf40-c_product-manual_1915467025.webp)
9.16. Temperature [55]
Reading this command will return the temperature in 100ths of a degree.
Read
Write
Persists
ui nt 32
-
-
9.17. Baud rate [90]
The baud rate as used by the serial interface. This parameter only takes effect when the serial interface is first
enabled after power-upor restart.
Reading this command will return the baud rate. Writing to this command will set the baud rate.
Value
Baud rate
[bps]
4
115200
5
230400
6
460800
7
921600
Read
Write
Persists
ui nt 8
ui nt 8
Yes
9.18. Distance [105]
NOTE: The data structure for reading/writingthis command has changed since firmware 1.0.1.
Reading thiscommandwill returnthe
aver age
,
cl osest
and
f ur t hest
distance withinan angularview
pointingin a specified direction. When writing to this command you can specify the direction and angular width of the
view that the results are calculated from. The response to the write command is the same as the read command.
Readings below the
Mini mumdi st ance
will be ignored.
SF40/C
Product manual
SF40/C -Product manual
|
24 of 30 |
© LightWare Optoelectronics (Pty) Ltd, 2019 |
www.lightware.co.za