SF000 LiDAR Sensor
Product guide
74. Noise
Reading this command will return the level of background noise.
Read
Write
Persists
uint32
-
-
75. Zero offset
Changing this offset value will change the Zero distance position for the output. This value is
written and read in mm.
Read
Write
Persists
int32
int32
Yes
76. Lost signal counter
The lost signal counter is used to determine the number of lost signal returns that needs to be
generated before a lost signal indication is output on the distance value. The lost signal
indication on the distance output value is -1000.
Read
Write
Persists
uint32
uint3
2
Yes
41 of 47