Section 7. Content of the Backup File 

7. 

Content of the Backup File 

The backup file contains numerous settings and parameters saved from the device. When the file 
is uploaded to a device, the following will be overwritten: 

MMX6x2-HT200 series matrix 

Local serial port

 

RS-232 mode, Control protocol, Baud rate, Data bits, Stop bits, Parity 
Port name and CI* port number 

Ethernet settings

 

Enable/Disable on Local, Link and TPS lines

 

HDMI input port

 

Audio mode, HDCP setting, Port name

 

Analog audio input port

 

Volume, Balance, Gain, Port name

 

TPS input port

 

Port names, TPS mode, PoE (enabled / disabled), Ethernet (Enable / Disable) 
Audio mode (Embedded / AUX1-4), HDCP setting 
RS-232 mode, Control protocol, Baud rate, Data bits, Stop bits, Parity, CI port number 
IR input port status (enable / disable), code length and repetition code 
IR input port – Command injection mode (On / Off) and CI port number 
IR output status (enable / disable), IR output modulation (enable / disable) 
IR output port – Command injection mode (On / Off) and CI port number 

HDMI output port

 

Power +5V mode, Audio mode, HDCP mode, HDMI mode, Port name 
Test pattern mode, clock source and type 

Analog audio output port

 

Volume, Balance, Gain, Mute setting, Port name

 

TPS output port

 

Port names, TPS mode, PoE (enabled / disabled), Ethernet (Enable / Disable) 
Test pattern mode, clock source and type 
HDCP mode, HDMI mode, Power +5V mode 
RS-232 mode, Control protocol, Baud rate, Data bits, Stop bits, Parity, CI port number 
IR input port status (enable / disable), code length and repetition code 
IR input port – Command injection mode (On / Off) and CI port number 
IR output status (enable / disable), IR output modulation (enable / disable) 
IR output port – Command injection mode (On / Off) and CI port number 

Network settings 

DHCP status (enable / disable) 
LW2, LW3 and HTTP port numbers 
Static IP address, Network mask, Gateway address 

Further settings

 

Emulated EDID list, User EDID data (U1-U12) 
Event manager: All Events’ settings (1-100)

 

All Presets’ settings (1-6)

 

* CI: Command Injection 

 

 

Содержание LW3

Страница 1: ...Configuration Cloning for LW3 Devices Setup Guide ...

Страница 2: ......

Страница 3: ...ice is powered and operational A computer with Lightware Device Controller software installed The application can be downloaded from the Support Downloads page of www lightware eu Make sure that the device and the computer are connected 3 Cloning Steps in a Nutshell Installing multiple devices with the same customized configuration settings can be done in a few easy steps Step 1 Configure one devi...

Страница 4: ...Create a full backup button You will be prompted to save the file to the computer The default file name is the following BACKUP_ DEVICE TYPE _SN SERIAL NUMBER LW3 E g backup_MMX6x2 HT220_SN5A003192 lw3 Step 6 Set the desired file name select the folder and save the file Hint Using the exact product type in the filename is recommended since it makes the file usage more comfortable About the backup ...

Страница 5: ... backup file is downloaded from the HT220 and uploaded to a HT200 matrix then this would result in errors when checking and uploading The restoring process is the following Step 1 Run Lightware Device Controller software and connect to the device UMX TPS TX100 series and HDMI TPS TX200 series via Ethernet MMX6x2 HT200 series via USB or via Ethernet Step 2 Select the Settings Backup tab from the me...

Страница 6: ...NAGEMENT NETWORK DhcpEnabled false SET MANAGEMENT NETWORK DhcpEnabled true Info The static IP address will be uploaded to the device if the referring line is in the backup file but will be ignored when DHCP is enabled Info The factory default IP address of the LW3 devices is static Case 2 Use static IP addresses Be aware that if the backup file is uploaded restored in multiple devices it will caus...

Страница 7: ...tput status enable disable IR output modulation enable disable IR output port Command injection mode On Off and CI port number HDMI output port Power 5V mode Audio mode HDCP mode HDMI mode Port name Test pattern mode clock source and type Analog audio output port Volume Balance Gain Mute setting Port name TPS output port Port names TPS mode PoE enabled disabled Ethernet Enable Disable Test pattern...

Страница 8: ...le Disable on Local and Link lines Serial port RS 232 mode Control protocol Baud rate Data bits Stop bits Parity Command Injection port number Port names GPIO ports Output level Pin direction Port names Audio and Video crosspoint Crosspoint state Mute and Lock states of Source and Destination ports Source port priority list Autoselect settings Further settings Emulated EDID list User EDID data U1 ...

Страница 9: ...its Stop bits Parity Command Injection port number Port names GPIO ports Output level Pin direction Port names Audio and Video crosspoint Crosspoint state Mute and Lock states of Source and Destination ports Source port priority list Autoselect settings Further settings Emulated EDID list User EDID data U1 U14 Event manager All Events settings 1 20 Device label and Front panel status locked unlock...

Отзывы: