6. Programmer's Reference
DVIDL-OPT series – User's Manual
25
6.3.5.
Delete EDID from Memory
Description
: Clear EDID from memory location <loc>.
Explanation
: All user EDIDs are cleared from memory.
Legend
: Depending on <loc>, one EDID or all EDIDs in a block can be cleared.
6.3.6.
Download EDID Content
Description
: EDID hex bytes can be read directly. The router will issue the whole content of the EDID present
on memory location <loc> (256 bytes).
Legend
: <B1>..<B256> are space separated hex characters represented in ASCII format.
Explanation
: Full EDID from memory location F1 is downloaded.
Format
Example
Command {DE<loc>}
{deu*}
Response (DE_OK)CrLf
(E_S_C)CrLf
(DE_OK)
(E_S_C)
<loc>
Result
Fxx
Not valid! Factory EDID cannot be deleted. No response.
Uxx
Specified User EDID is deleted.
Dxx
Specified Dynamic EDID is deleted. It will be empty until a new monitor is connected.
Exx
Specified Emulated EDID cleared. By default F49 EDID is copied to it.
F*
Not valid! Factory EDID cannot be deleted. No response.
U*
All User EDIDs are deleted.
D*
All Dynamic EDIDs are deleted. They will be empty until a new monitor is connected.
E*
All Emulated EDIDs are cleared. By default F49 EDID is copied to them.
Format
Example
Command
{WE<loc>}
{wef1}
Response (EB#<loc>•<B1> •<B2>•..•<B256>)CrLf
(EB#F1 00 FF FF FF FF FF FF 00 32 F2 00
00 00 .. .. .. 00 00)
6.3.7.
Upload EDID Content to the Router
Description
: EDID hex bytes can be written directly to the user programmable memory locations. The
sequence is the following:
Step 1.
Prepare the router to accept EDID bytes to the specified location <loc> with command {WL#<loc>}.
Step 2.
Router responds that it is ready to accept EDID bytes with (E_L_S)CrLf.
Step 3.
Send 1 block of EDID (1 block consist of 8 bytes of hex data represented in ASCII format) with
command {WB#<num>•<B1>•<B2>•<B3>•<B4> •<B5>•<B6>•<B7>•<B8>}.
Step 4.
The router acknowledges with response (EL#<num>).
Step 5.
Repeat steps 3 and 4 to send the remaining 31 blocks of EDID (32 altogether).
Step 6.
After the last acknowledge, the router indicates that the EDID status changed by sending (E_S_C)
CrLf.
Legend
: <num> represents the sequential number of every 8 byte part of EDID. <num> is between 1 and 32.
<B1>..<B256> are the bytes of EDID.
Explanation
: Full EDID uploaded to memory location U3.
Format
Example
Command
{WL#<loc>}
{wl#U3}
Response (E_L_S)CrLf
(E_L_S) CrLf
Command
{WB#1•<B1>•<B2>•<B3>•<B4>•<B5>
•<B6>•<B7>•<B8>}
{WB#1 00 FF FF FF FF FF FF 00}
Response (EL#<num>)CrLf
(EL#1) CrLf
Command
{WB#2•<B9>•<B10>•<B11>•<B12>
•<B13>•<B14>•<B15>•<B16>}
{WB#2 38 A3 8E 66 01 01 01 01}
Response (EL#<num>) CrLf
(EL#2) CrLf
…
…
Command
{WB#32•<B249>•<B250>•<B251>
•<B252>•<B253>•<B254>•<B255>
•<B256>}
{WB#32 36 59 42 0A 20 20 00 96}
Response (EL#<num>) CrLf
(EL#32) CrLf
Response (E_S_C) CrLf