Preparation for

 

fitting

  

 

Note: Only install the light on a solid surface. The fitting bracket supplied is suitable for ceiling installation. 

 

1.  In the packaging the fitting bracket for the luminaire is at an angle. For installation the fitting bracket must 

be set at right angles after unpacking. 

 

 

 

 

 

 

 

 

 

2.  Select a suitable or desired horizontal installation location with sufficient air circulation. The mounting 

holes are 105 mm, for the mounting of the fitting bracket use two stainless steel screws with a diameter 

of at least 6 mm. Using any other screw material can result in contact corrosion on the fitting bracket. 

The distance from the centre to the inner holes is 68 mm and to the outer holes 108 mm. When drilling in 

walls or ceilings, please be aware there may be cables of pipework there, which you might hit with the 

drill. 

 

 

 

 

 

 

 

3.  Then connect the existing, flexible connection cable for mains 

supply on the product to the existing power supply on site, pro-

tected in an external power distribution box (not included in the 

scope of delivery), with at least the same protection type as 

the product, in accordance with the following illustration. For 

the connection terminal, we recommend using a 3 pole, insu-

lated connector from the WAGO 294 series for a nominal 

cross section of 2.5 mm² and a nominal voltage of at least 500 

V, meeting the VDE directives 0700 (EN 60 335-1),VDE 0613 

(EN 60 998) and VDE 0711 (EN 60 598-1) for use in devices  

and luminaires up to 24 A. 

 

 

 

 

2160 mm 

136 mm 

68 mm 

108 mm 

Fitting bracket 

 

Содержание Lucid sirius 1-10 V

Страница 1: ...lation and service instructions Lucid sirius LED luminaire Please read these instructions before installing the luminaires using them for the first time storage or handling These installation and serv...

Страница 2: ...ation and maintenance of this product It applies for all versions of the Lucid sirius LED luminaire LED luminaire in the Lucid sirius range are intended for professional use indoors Technical personne...

Страница 3: ...e all because of a number of special technical fea tures which guarantee the best possible technical performance These include highly efficient lens optics high quality housing materials constant curr...

Страница 4: ...mergency lighting for office multimedia and household devices and confirms the conformance with the European statutory requirements and enables an easier market access in these product areas within th...

Страница 5: ...not install the product on a damp or conductive surface To avoid any hazard a damaged outer flexible lead on this light may only be replaced by the manufac turer their representative or a comparable q...

Страница 6: ...y other screw material can result in contact corrosion on the fitting bracket The distance from the centre to the inner holes is 68 mm and to the outer holes 108 mm When drilling in walls or ceilings...

Страница 7: ...nnected singly Neutral N blue Phase L brown or black Grounding PE yellow green Grounding is mandatory and may not be omitted The grounding of the LED luminaire is done via the green yellow connection...

Страница 8: ...nal voltage of at least 500 V meeting the VDE directives 0700 EN 60 335 1 VDE 0613 EN 60 998 and VDE 0711 EN 60 598 1 and VDE 24 EN 2 598 1 for use in devices and lights up to 24 A nominal cur rent 1...

Страница 9: ...rature of 80 C at the marking shown in the illustration may not be exceeded By maintaining the maximum temperature at the tc position it is ensured that components will become hotter than permitted At...

Страница 10: ...icial damage During maintenance the product should be disconnected from the power supply and steps take to ensure it cannot be switched on again accidentally We recommend cleaning with a damp soft lin...

Страница 11: ...Co KG Gaildorfer Str 6 D 71522 Backnang Tel 49 7191 323020 Fax 49 7191 323029 info lights de IG_Lucid_sirius_DE_23 06 2017_V3 0 Similar to illustrations technical data are subject to change Technical...

Страница 12: ...ope GmbH Co KG Gaildorfer Str 6 D 71522 Backnang Tel 49 7191 323020 Fax 49 7191 323029 info lights de IG_Lucid_sirius_DE_23 06 2017_V3 0 Similar to illustrations technical data are subject to change D...

Страница 13: ...de LIGHTS 4 Europe GmbH Co KG Gaildorfer Str 6 D 71522 Backnang Tel 49 7191 323020 Fax 49 7191 323029 info lights de IG_Lucid_sirius_DE_23 06 2017_V3 0 Similar to illustrations technical data are subj...

Страница 14: ...our by non authorised third parties e Use of unsuitable accessories f Unauthorised opening of the housing g Removal of the type plate 4 The following are also excluded Damage caused by improper handl...

Страница 15: ...g instructions cannot consider every possible application The LED lumi naires are intended for use indoors In addition we would like to point out that the contents of these operating instructions are...

Отзывы: