Installation and service guide for

 

Lucid lane plus

 

For the following models: 

40 Watt

60 Watt

80 Watt

Read these instructions before installing, operating, storing or handling the appliance. 

Figure 1: Top view

 

Figure 2: Bottom view

 

Содержание Lucid lane plus 3040

Страница 1: ...Lucid_lane_plus_EN_2015 06 01_V1 1 Similar to illustrations technical data are subject to change Installation and service guide for Lucid lane plus For the following models 40 Watt 60 Watt 80 Watt Read these instructions before installing operating storing or handling the appliance Figure 1 Top view Figure 2 Bottom view ...

Страница 2: ...of contents Introduction 3 Intended use 3 EU Directives 3 Identification label 4 Safety measures 4 Danger of electric shock 4 Installation 5 Product description 5 Models 5 Luminous flux and illumination 5 Assembly 6 Adjusting the tilt angle 6 Electrical connection 6 Attachment 7 Cleaning and maintenance information 8 Technical information 8 Available models 9 Warranty 10 Legal information 11 Decla...

Страница 3: ...and service instructions are applicable to all Lucid lane plus LED luminaire models with a power consumption of 40 60 or 80 watts The LED luminaires of the Lucid lane plus series are appliances for professional use both indoors and outdoors They are designed to illuminate streets and all types of areas The installation and maintenance of the appliances may only be carried out by qualified electric...

Страница 4: ...n identification label Safety measures Danger of electric shock Always connect the luminaire to a suitable power supply Disconnect the luminaire from the power supply and all other devices in the event of a fault Do not open the luminaire casing the lamp cannot be exchanged Ensure that only qualified specialists electrical engineers are responsible for installing and maintaining the luminaires If ...

Страница 5: ...safety ladders or appropriate safe installation aids Ensure that you are protected from a fall Product description Models The LED luminaires of the Lucid lane plus series are supplied with an integrated power supply driver to operate the luminaire The luminaires are connected via a 3 wire cable appropriate for operating the luminaire The luminaires do not require maintenance All varieties of lumin...

Страница 6: ...connect or disconnect while voltage is connected Installation must be carried out only by a qualified electrician Assembly is carried out in 3 stages on a suitable pole with a diameter of 48 mm to 63 mm Check the voltage supply before installation The AC voltage must be between 90 V and 305 V Adjusting the tilt angle After loosening the screws the tilt angle can be set between 45 and 105 in 15 inc...

Страница 7: ...on class of the luminaire Connect the cable as shown in the following diagram Whereby PE green yellow protective conductor L brown cable phase N blue neutral conductor Figure 6 Electrical connection The luminaires are earthed via the green yellow protective conductor Do not damage the power supply when closing Attachment Slide the luminaire up the pole and tighten all six M10 screws equally Figure...

Страница 8: ...supply The LED module must not be opened Use a damp cloth to clean the appliance Do not use cleaning agents Damaged cables must be replaced with new cables Technical information Input voltage 90 305 V AC voltage System efficiency 120 lm W Colour rendering index 80 other indices upon request Colour temperature 3000 K 4000 K 5000 K 6500 K Beam angle 150 65 Permissible ambient temperature 30 to 45 Ov...

Страница 9: ...vailable upon request 18643 Lucid lane plus 3040 40 W 3000 K 4536 lm 18644 Lucid lane plus 4040 40 W 4000 K 5040 lm 18645 Lucid lane plus 5040 40 W 5000 K 5040 lm 18646 Lucid lane plus 6040 40 W 6500 K 5040 lm 18663 Lucid lane plus 3060 60 W 3000 K 6075 lm 18664 Lucid lane plus 4060 60 W 4000 K 6750 lm 18665 Lucid lane plus 5060 60 W 5000 K 6750 lm 18666 Lucid lane plus 6060 60 W 6500 K 6750 lm 18...

Страница 10: ... or improper use d Repairs or modifications undertaken by non authorised third parties e Use of unsuitable ancillary parts f The following is also excluded damage caused by improper treatment assembly or maintenance of the light see assembly instructions damage as a result of force majeure fire vandalism or accidental damage 5 LIGHTS will deal with any damage arising within the warranty period upo...

Страница 11: ... instructions for use cannot cover every possible scenario We would furthermore like to point out that the contents of these instructions for use are not part of a previous or existing agreement acceptance or legal relationship nor are they intended as an amendment to such These instructions for use contain information protected by copyright law Photocopies or translation into other languages is n...

Страница 12: ...T6ccB4Cx STLE 80S T c T6ccB4Cx Item Number 18643 18644 18645 18646 18663 18664 18665 18666 186863 18684 18685 18686 Applicable Directive European Union EC Low Voltage Directive 2006 95 EC EN 60598 1 2008 A11 2009 and EN 60598 2 3 2003 Technical Standard EMC Directive 2004 108 EC Test Standards EN 55015 2006 A2 2009 IEC 61000 3 2 2005 A1 2008 A2 2009 IEC 61000 3 3 2013 EN 61547 2009 IEC 61000 4 2 2...