DB612 DISTRIBUTED DIMMING BAR 

 Version: 1.1  

 

 

 

 

 

 

 

 

 

OWNERS MANUAL

  

 

 

 

 

 

 

 

 

 

  01/06/2022 

www.lightronics.com 

Lightronics Inc   

 

 

 

 

 

 

 

509 Central Drive, Virginia Beach, VA  23454 

 

 

 

 

 

 

   Tel  757 486 3588 

CHANNEL OUTPUT CONNECTIONS (LAMP LOAD 
CONNECTIONS) 
 
Dimmer channel output connectors are on the face 
of the unit. Two connections are available for each 
channel (the optional twist-lock panels have one 
connection per channel).  The numbering for the 
channels is shown on the unit center faceplate.  The 
maximum load for each channel is 1200 Watts or 10 
Amps. 
 
CONTROL SIGNAL 
 
Connect a Lightronics or other DMX512 compatible 
control console to the DB612  using the MALE 5-pin 
XLR connector located on the center faceplate of the 
unit.  This connector is marked DMX IN.  The 
FEMALE 5-pin XLR connector is provided so you 
can connect multiple dimmers as a system.  This 
connector is marked DMX OUT and will pass the 
DMX signal through to additional devices on a DMX 
chain.  Connector wiring information is given below. 
 
 
 
 
 
 
 
 
 
 
DMX TERMINATION 
 
A DMX device chain should be electrically 
terminated at the last device (and only the last 
device) on the control chain.  A DMX terminator 
consists of a 120 Ohm resistor connected across the 
DMX DATA + and DMX DATA - lines.  The DB612 
contains a built in terminator which may be switched 
in or out. The left end DIP switch on the unit center 
panel will apply the terminator if moved to the UP 
position. 
 

OPERATION 

 
CIRCUIT BREAKERS 
 
A small plate near one end of the unit contains a 10 
Amp magnetic circuit breaker for each dimmer 
channel.  To operate a channel,  the associated 
circuit breaker must be closed.  Channel numbers 
for the circuit breakers are  located on the circuit 
breaker panel.  If the circuit breaker will not remain 
closed then there is an overload at the lamp for that 

channel which MUST be corrected before operation 
can continue. 
 
INDICATORS 
 
There is a neon lamp for each channel on the center 
faceplate.  This lamp indicates when INPUT power is 
available for the channel (Input power on and 
channel circuit breaker closed).  There is also a row 
of six red LEDs on the center faceplate which give 
an approximate indication of the channel output 
intensity. 
 
SETTING THE UNIT STARTING ADDRESS 
 
The DB612 may be addressed to any block of six 
DMX addresses between 1 and 507.  Set the rotary 
decade switches on the unit center panel to the 
number corresponding to the DMX address which 
will be used for the first channel of the DB612.  The 
remaining five channels will be assigned to 
consecutive higher DMX addresses.  Multiple 
DB612s may be set to the same address block. 
 
CHANNEL TESTING 
 
DB612 channel operation may be tested at the unit.  
The six small pushbuttons at the lower right of the 
center faceplate will activate the associated dimmer 
channel to full ON and OFF when pushed. In 
addition to channel testing, this function is useful 
when adjusting or focusing lamps.  A channel which 
has been turned on by the test buttons can be 
turned back off at the DMX console by setting the 
associated channel fader to full ON and then back 
OFF.  The red LED indicators located directly above 
the buttons indicate when the channel is on.  
 
RELAY MODE OPERATION 
 
Individual channels of the DB612 may be switched 
into the relay mode.  In this mode the dimmer 
channel will either be fully on or fully off depending 
on the channel intensity setting at the control 
console.  The channel will remain off until a console 
fader position threshold point is crossed.  When this 
occurs, the corresponding dimmer channel will 
switch to a full on condition.  This mode is useful to 
control lamps and other lighting devices which 
cannot be dimmed.    
 
There is a block of seven DIP switches on the center 
panel of the unit.  The six right hand switches are 
used to switch the corresponding channel into the 

PIN NUMBER 

SIGNAL NAME 

DMX Common 

DMX Data - 

DMX Data + 

Not Used 

Not Used 

 