Specplus
SPS2GFSVA232
Page 2 of 2
2' x 4' Recessed Fluorescent, Lens Frame Troffer
Static, 2 Lamp T8 or T5
Ordering Information
Explanation of Catalog Number. Example: SPS2GFSVA232UNVHI
Options/Accessories
Special Lenses
: Substitute
VY
for
VA
(standard) = .125" nominal pattern 12 with 7.8 oz. average weight
per square foot. Substitute
VI
for
VA
(standard) = .125" nominal pattern 12 with 6.8 oz. average weight per
square foot. Substitute
S1
or
S2
for
VA
(standard) = Sky Acrylic Lens (see Sky Lenssell sheet for
further details).
Plaster Frame
: Catalog Number:
PF24
.
Continuous Row Installation
: For F type fixtures, half width flanges are required between
fixtures. Order Catalog Number:
2FC TRIM CSP
(each joint).
Radio Interference Filter
: To order one RIF per fixture; SUFFIX:
R
.
To order one RIF per ballast; SUFFIX:
B
.
Fusing
: Internal fast-blow fusing. SUFFIX
A
.
Internal slow-blow fusing. SUFFIX
C
.
Electrical Wiring Options
: Consult factory.
Drywall Kit
: Order Catalog Number:
FK92X4
. (Request Folio OA30-10 Rev. A).
Chicago Plenum
: SUFFIX:
C
.
Specifications
Performance
: In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1, reflectance
80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .88. To prevent glare the VCP shall
be not less than 59 either lengthwise or crosswise (at 100fc level) and the average brightness at 65°
shall not exceed 1640 candelas per square meter. To control veiling reflections, luminaire output in
the 30°-90° zone shall not be less than 69.4%.
Specifications (continued)
Materials
:
Chassis parts
are die-formed code gauge cold rolled steel. Housing with side rails hemmed
over and housing ends turned-in for safe handling.
Finish
:
Chassis exterior
–black baked polyester enamel.
Cavity
–white baked polyester enamel
minimum 86% reflectance. Phosphate undercoating.
Lenses
:
VA
(standard) extruded virgin acrylic, 3/16" square based female cones, running 45° to the
panel edge, .095" nominal thickness (similar to pattern 12).
VY
(optional) .125" nominal pattern 12
with 7.8 oz. average weight per square foot.
VI
(optional) .125" nominal pattern 12 with 6.8 oz. aver-
age weight per square foot.
S Series
(optional) search Healthcare Sky at lightolier.com for details.
Electrical
: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of
ballast, use wire suitable for at least 90°.
Labels
: I.B.E.W. UL and ULc Listed.
This product may have a mercury containing lamp.
Manage in accord with Disposal Laws. See: www.lamprecycle.org
Specplus:
Recessed
fluorescent
troffer
S
Static
2
Fixture
Width
Ceiling Type:
G
= Grid (lay-in T bar)
F
= Flanged (over
lap) Z spline and
plaster frame
Lens Frame:
FS
= Flat steel frame.
RA
= Regressed
aluminum frame.
FA
= Flat aluminum
frame.
Lens Shielding
Type:
VA
=Virgin acrylic
(standard)
S1
=Sky lens 1
S2
=Sky lens 2
See options and
consult factory
2
Lamp
Quantity
Options:
Add appropriate suffix
to catalog no., ie: (A)
Ballast Type:
<
20THD
<
10THD
1-2 Lamp Elec. T8
SO *
H
I
*
1-2 Lamp 28W Elec. T5
–
P
I
†
1-2 Lamp 28W Elec. T5
–
†
PG ††
1-2 Lamp 54W Elec. T5
–
†
PG ††
LOL T8 Dimming
PS
–
Other dimming options. Consult factory.
†
*Instant Start Standard
†
†Instant Start (120, 277 or
UNV
)
††Program Rapid Start (
UNV
only)
NOTE:
For
T8 UNV
, you must use
H
I
Ballast Code.
Voltage:
120, 277 or
UNV
=120-277
Lamp Type/
Fixture Length:
32
=32W T8
28
=28W T5
54
=54W T5
(Nominal 48")
SP
Standard Specplus Plus
SX
For NYC Code – Local 3 Manufactured
0.0
45.0
90.0
FLUX
0
1817
1817
1817
5
1811
1812
1815
173
15
1751
1773
1798
502
25
1613
1680
1748
775
35
1388
1512
1622
943
45
1083
1220
1325
932
55
699
803
859
707
65
388
406
450
414
75
218
181
202
214
85
86
76
68
83
90
0
0
0
Model No. SPS2GFSVA232120SO
LER = FP - 67.4
IW - 61.2
BF - 0.87
Comparative yearly lighting energy cost per
1000 lumens = $3.56
Report Number: ITL49784
Catalog Number: SPS2GFSVA232120SO
Lamps: (2) F32T8
Luminaire: 2' x 4' SpecPlus with regressed
aluminum door frame and extruded
virgin acrylic shielding .095" nominal
thickness (similar to pattern 12).
Ballast: M2-RN-T8-1LL-D-120
Report is based on 2850 Lumens per lamp.
Efficiency: 83.2%
CIE Type-Direct-Indirect
Plane:
0-Deg
90-Deg
Spacing Criteria:
1.2
1.4
Shielding Angles:
90
90
Plane:
0-Deg
90-Deg
Luminous Length:
46.000
21.875
CANDELA DISTRIBUTION
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
0
RC
80
50
30
RW 70 50 30 50 30 10 50 30 10
0
1 91 88 84 82 80 77 79 77 75
0
2 84 77 72 73 69 65 70 67 64
0
3 77 68 62 65 60 55 62 58 54
0
4 70 61 54 58 52 48 56 51 47
0
5 65 55 48 52 46 42 50 45 41
0
6 60 49 42 47 41 37 46 40 36
0
7 56 45 38 43 37 33 42 36 32
0
8 52 41 34 39 33 29 38 33 29
0
9 49 38 31 36 30 26 35 30 26
10 46 35 28 34 28 24 33 28 24
ZONE
LUMENS % LAMP
% FIXT
0
0-
0
30
1149
25.4
30.6
0
0-
0
40
2392
42.0
50.4
0
0-
0
60
4032
70.7
85.0
0
0-
0
90
4743
83.2
100.0
90-180
000
0
0.0
00
0.0
0
0-180
4743
83.2
100.0
ZONAL LUMEN SUMMARY
Job Information
Type:
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595
02/10
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © Philips Group
Section 1A/Folio E60-30 Rev. B
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG.
0-DEG.
45-DEG.
90-DEG.
45
2358.
2657.
2885.
55
1877.
2156.
2306.
65
1414.
1479.
1640.
75
1297.
1077.
1202.
85
1519.
1343.
1201.
LUMINANCE DATA IN CANDELA/SQ. METER
Photometry
Sky Lens Options
S1
S2