background image

Specplus

SPS2GFSVA232

Page 2 of 2

2' x 4' Recessed Fluorescent, Lens Frame Troffer

Static, 2 Lamp T8 or T5

Ordering Information

Explanation of Catalog Number. Example: SPS2GFSVA232UNVHI

Options/Accessories

Special Lenses

: Substitute

VY

for

VA

(standard) = .125" nominal pattern 12 with 7.8 oz. average weight

per square foot. Substitute

VI

for

VA

(standard) = .125" nominal pattern 12 with 6.8 oz. average weight per

square foot. Substitute

S1

or

S2

for

VA

(standard) = Sky Acrylic Lens (see Sky Lenssell sheet for

further details).

Plaster Frame

: Catalog Number:

PF24

.

Continuous Row Installation

: For F type fixtures, half width flanges are required between

fixtures. Order Catalog Number:

2FC TRIM CSP

(each joint).

Radio Interference Filter

: To order one RIF per fixture; SUFFIX:

R

.

To order one RIF per ballast; SUFFIX:

B

.

Fusing

: Internal fast-blow fusing. SUFFIX

A

.

Internal slow-blow fusing. SUFFIX

C

.

Electrical Wiring Options

: Consult factory.

Drywall Kit

: Order Catalog Number:

FK92X4

. (Request Folio OA30-10 Rev. A).

Chicago Plenum

: SUFFIX:

C

.

Specifications

Performance

: In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1, reflectance

80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .88. To prevent glare the VCP shall
be not less than 59 either lengthwise or crosswise (at 100fc level) and the average brightness at 65°
shall not exceed 1640 candelas per square meter. To control veiling reflections, luminaire output in
the 30°-90° zone shall not be less than 69.4%.

Specifications (continued)

Materials

:

Chassis parts

are die-formed code gauge cold rolled steel. Housing with side rails hemmed

over and housing ends turned-in for safe handling.

Finish

:

Chassis exterior

–black baked polyester enamel.

Cavity

–white baked polyester enamel

minimum 86% reflectance. Phosphate undercoating.

Lenses

:

VA

(standard) extruded virgin acrylic, 3/16" square based female cones, running 45° to the

panel edge, .095" nominal thickness (similar to pattern 12).

VY

(optional) .125" nominal pattern 12

with 7.8 oz. average weight per square foot.

VI

(optional) .125" nominal pattern 12 with 6.8 oz. aver-

age weight per square foot.

S Series

(optional) search Healthcare Sky at lightolier.com for details.

Electrical

: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of

ballast, use wire suitable for at least 90°.

Labels

: I.B.E.W. UL and ULc Listed.

This product may have a mercury containing lamp.
Manage in accord with Disposal Laws. See: www.lamprecycle.org

Specplus:

Recessed

fluorescent

troffer

S

Static

2

Fixture

Width

Ceiling Type:

G

= Grid (lay-in T bar)

F

= Flanged (over

lap) Z spline and
plaster frame

Lens Frame:

FS

= Flat steel frame.

RA

= Regressed

aluminum frame.

FA

= Flat aluminum

frame.

Lens Shielding

Type:

VA

=Virgin acrylic

(standard)

S1

=Sky lens 1

S2

=Sky lens 2

See options and

consult factory

2

Lamp

Quantity

Options:

Add appropriate suffix

to catalog no., ie: (A)

Ballast Type:

<

20THD

<

10THD

1-2 Lamp Elec. T8

SO *

H

I

*

1-2 Lamp 28W Elec. T5

P

I

1-2 Lamp 28W Elec. T5

PG ††

1-2 Lamp 54W Elec. T5

PG ††

LOL T8 Dimming

PS

Other dimming options. Consult factory.

*Instant Start Standard

†Instant Start (120, 277 or

UNV

)

††Program Rapid Start (

UNV

only)

NOTE:

For

T8 UNV

, you must use

H

I

Ballast Code.

Voltage:

120, 277 or

UNV

=120-277

Lamp Type/

Fixture Length:

32

=32W T8

28

=28W T5

54

=54W T5

(Nominal 48")

SP

Standard Specplus Plus

SX

For NYC Code – Local 3 Manufactured

0.0

45.0

90.0

FLUX

0

1817

1817

1817

5

1811

1812

1815

173

15

1751

1773

1798

502

25

1613

1680

1748

775

35

1388

1512

1622

943

45

1083

1220

1325

932

55

699

803

859

707

65

388

406

450

414

75

218

181

202

214

85

86

76

68

83

90

0

0

0

Model No. SPS2GFSVA232120SO

LER = FP - 67.4

IW - 61.2

BF - 0.87

Comparative yearly lighting energy cost per

1000 lumens = $3.56

Report Number: ITL49784
Catalog Number: SPS2GFSVA232120SO
Lamps: (2) F32T8
Luminaire: 2' x 4' SpecPlus with regressed

aluminum door frame and extruded
virgin acrylic shielding .095" nominal
thickness (similar to pattern 12).

Ballast: M2-RN-T8-1LL-D-120
Report is based on 2850 Lumens per lamp.
Efficiency: 83.2%
CIE Type-Direct-Indirect
Plane:

0-Deg

90-Deg

Spacing Criteria:

1.2

1.4

Shielding Angles:

90

90

Plane:

0-Deg

90-Deg

Luminous Length:

46.000

21.875

CANDELA DISTRIBUTION

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20

0

RC

80

50

30

RW 70 50 30 50 30 10 50 30 10

0

1 91 88 84 82 80 77 79 77 75

0

2 84 77 72 73 69 65 70 67 64

0

3 77 68 62 65 60 55 62 58 54

0

4 70 61 54 58 52 48 56 51 47

0

5 65 55 48 52 46 42 50 45 41

0

6 60 49 42 47 41 37 46 40 36

0

7 56 45 38 43 37 33 42 36 32

0

8 52 41 34 39 33 29 38 33 29

0

9 49 38 31 36 30 26 35 30 26

10 46 35 28 34 28 24 33 28 24

ZONE

LUMENS % LAMP

% FIXT

0

0-

0

30

1149

25.4

30.6

0

0-

0

40

2392

42.0

50.4

0

0-

0

60

4032

70.7

85.0

0

0-

0

90

4743

83.2

100.0

90-180

000

0

0.0

00

0.0

0

0-180

4743

83.2

100.0

ZONAL LUMEN SUMMARY

Job Information

Type:

For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595

02/10

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © Philips Group

Section 1A/Folio E60-30 Rev. B

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG.

45-DEG.

90-DEG.

45

2358.

2657.

2885.

55

1877.

2156.

2306.

65

1414.

1479.

1640.

75

1297.

1077.

1202.

85

1519.

1343.

1201.

LUMINANCE DATA IN CANDELA/SQ. METER

Photometry

Sky Lens Options

S1

S2

Отзывы: