background image

CAVITY

TRACK

Fig. 3

LOCK TO LOWER

CABLE; DEPRESS 

HOLD THIS

RAISE

PULL TO

before installation. To prevent electric shock, turn off electricity at fuse box before proceeding.

To assure full compliance with local codes and regulations, check with your local electrical inspector

This luminaire is intended for installation in accordance with the National Electrical Code and local regulations.

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING LUMINAIRE

Page 1 of 4

A0101

INSTRUCTION SHEET NO.

Retain these instructions for maintenance reference.

LIGHTOLIER a GENLYTE THOMAS company.

631 Airport Road, Fall River, MA 02720

WARNING: Do not damage WHITE, BLACK, or GREEN insulation.

be removed.

NOTE: To reposition HOUSING, HOUSING COVER does not have to

pull CABLE down. See. Fig 3.

NOTE: To lower luminaire, hold CABLE, depress CABLE LOCK, and

PRIOR TO WIRING.

WARNING: Do not attach POWER STEM BASE into TRACK

INSIDE TRACK CAVITY (see Fig. 3).

POWER TO TRACK. NEVER PLACE AIRCRAFT CABLE 

WARNING: TO PREVENT ELECTRIC SHOCK, TURN OFF

   using HOUSING SCREWS. See Fig. 10.

8. Fasten POWER STEM HOUSING to POWER STEM BASE

          BLACK WIRE to BRASS SCREW

          WHITE WIRE to SILVER SCREW

7. Connect: GREEN WIRE to GREEN SCREW MARKED "GND" 

6. Twist strands of wire together and form a "J" loop. See Fig. 10.

5. Tie knot in CORD as shown in Fig. 9.

4. Strip CORD and WIRES to lengths shown in Fig. 9.

3. Pull CORD through POWER STEM HOUSING. See Fig. 9.

   If CORD RETAINERS are not used, cut off. See Fig. 8.

   standard TIE WRAP (local hardware item) may also be used.

   CORD through RETAINERS and position where needed. A 

2. If a CORD RETAINER is desired, two are provided. Pull 

   it up to the TRACK and cutting. See Fig. 7.

1. Leaving slack, CORD length can be determined by bringing

PowerWash T5 POWER STEM:

INSTRUCTIONS FOR WIRING SUSPENDED 

TM

   HOUSING 90fl counter clockwise. See Fig. 2.

8. To remove or reposition on track, rotate SUSPENSION 

   HOUSING as shown in Fig. 6.

7. Slide up HOUSING COVER and snap onto SUSPENSION 

   COPPER STOP (provided) onto AIRCRAFT CABLE. See Fig. 5.

   CABLE leaving approx 1/2" above CABLE LOCK. Crimp 

   in Fig. 4. If no adjustment will be desired, cut AIRCRAFT 

   BODY and pinned down using HOUSING SLOTS as shown 

   feet of AIRCRAFT CABLE can be wrapped around HOUSING

6. If future suspension length adjustment is desired, up to two 

   CABLES through CABLE LOCK. See Fig. 3.

5. Adjust suspension length and leveling by pulling AIRCRAFT 

4. Rotate SUSPENSION HOUSINGS 90fl clockwise. See Fig. 2.

   Fig. 2.

   bottom of HOUSING pointing toward BEAD on TRACK. See 

3. Insert SUPSENSION HOUSINGS into TRACK with ARROW on 

   CABLE LOCK. See Fig. 1.

   pull AIRCRAFT CABLE through, leaving approx 1" above

2. Unwrap AIRCRAFT CABLE. While depressing  CABLE LOCK, 

   See Fig. 1.

1. Remove WARNING LABEL on SUSPENSION HOUSING. 

T5 SUSPENSION HOUSING TO LYTESPAN TRACK:

INSTRUCTIONS FOR ATTACHING SUSPENDED PowerWash 

 A LYTESPAN  TRACK SYSTEM. FOR USE WITH LYTESPAN TRACK SYSTEMS ONLY.  

INSTRUCTIONS FOR ATTACHING SUSPENDED PowerWash  T5 SUSPENSION HOUSING TO

NOTE: Not for use with ProSpec  Track.

WARNING: If Mounting on wall or sloped ceiling, COPPER STOP must always be used

Fig. 5

STOP

COPPER

ARROW

CABLE

AIRCRAFT

SLOTS

HOUSING 

BODY

HOUSING

Fig. 4

HOUSING

SUSPENSION

BEAD

TRACK

Fig. 2

HOUSING SCREWS

STEM BASE

POWER 

POWER STEM HOUSING

   (GREEN WIRE)

GREEN "GND" SCREW

(WHITE WIRE)

SILVER SCREW

(BLACK WIRE)

BRASS SCREW

WIRES

Fig. 10

3/4"

 1/4"

2

3/4"

 

 15/16"

1

WIRES

POWER STEM HOUSING

CORD

   GREEN

WHITE

BLACK

Fig. 9

RETAINER

CORD

CORD

Fig. 8

CORD

TRACK

Fig. 7

COVER

HOUSING

Fig. 6

1"

CABLE LOCK

LABEL

WARNING

CABLE

AIRCRAFT

Fig. 1

Fig. 22

  

Fig. 21

  

LAMPS

SOCKETS

BRACKET

SOCKET

SOCKETS

BRACKET

SOCKET 

Retain these instructions for maintenance reference.

before installation. To prevent electric shock, turn off electricity at fuse box before proceeding.

To assure full compliance with local codes and regulations, check with your local electrical inspector

This luminaire is intended for installation in accordance with the National Electrical Code and local regulations.

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING LUMINAIRE

LIGHTOLIER a GENLYTE THOMAS company.

631 Airport Road, Fall River, MA 02720

INSTRUCTION SHEET NO.

A0101

 Page: 4 of 4

MAKING ANY ADJUSTMENTS!

CAUTION: ALLOW TIME FOR LUMINAIRE TO COOL BEFORE

rotates 360fl.

DOING SO MAY CAUSE AN ELECTRICAL HAZARD). HEAD 

rotation stops (DO NOT FORCE LUMINAIRE PAST STOPS. 

Rotate HEAD of luminaire to desired position. Luminaire has

SEE LABEL ON LUMINAIRE FOR PROPER WATTAGE.

WARNING: USE PROPER WATTAGE T5 HIGH OUTPUT LAMPS ONLY.

AIMING INSTRUCTIONS (see Fig. 23)

TM

   remove from SOCKET.

7. To remove LAMP, repeat steps 1-3. Rotate LAMP(s) 90fl and

   (see Fig. 22).

6. Push SOCKET BRACKETS back into their original position

5. For two LAMP luminaire, repeat step 4 for the second LAMP.

   in place.

4. Insert LAMP into SOCKET and rotate LAMP 90fl locking it

   required. Pull with hands.

3. Slide out both SOCKET BRACKETS (see Fig. 21). No tools

2. Remove LOUVER (see Page 3).

1. Turn off power to track.

PowerWash T5 LUMINAIRE:

INSTRUCTIONS FOR LAMPING A SUSPENDED 

INSTRUCTIONS FOR LAMPING AND OPERATING A SUSPENDED PowerWash  T5 LUMINAIRE.

will extinguish when one fails.

Assure that both lamps are properly installed. Also, both lamps

NOTE: A two lamp luminaire will not operate with only one lamp.

Fig. 23

HEAD

IS: 9279

IS: 9279

Отзывы: