Lightolier Md.Coffer MDCGWSVA2SB4SB Скачать руководство пользователя страница 3

MD*Coffer 2' x 4' Recessed or Surface 

MDCGWSVA2SB4SB

Page 3 of 4

Multi-Function Patient Lighting

Indirect Ambient Light with Perforated Mesh Shield

3"

6"

12"

Wall

Bed

12"

Night Light 

(Optional)

Indirect 9 or 7 watt PL lamp shielded by perforated mesh
with internal white acrylic overlay.
No glare to any patient.
Wired for independent switching.

Options 

3

4

3

3

2

2

1

3

4

3

3

2

2

1

3

4

3

3

2

2

1

Pillow speaker (by others)

FOOTCANDLES ON BED

PL9 or PL7 Night Light. Suffix: PL

(Lamps not included)

Night Light

MD*Coffer’s optional low voltage (1-3 volts) sequential switch mounted in the fixture is listed in
compliance with UL 544 for medical and dental equipment. Two red wires coming from the fixture
can be wired to a wall receptacle (by others) for use with that manufacturer's pillow speaker. The
pillow speaker is used to control the television, call the nurse and control the lighting. To control
the lighting it should be specified to have a normally open contact switch.
Pressing this switch on the pillow speaker the first time, turns the ambient light on; pressed a
second time, turns the reading light on and the ambient light off; pressed a third time, turns both
the ambient and reading lights on; pressed a fourth time turns both lights off. Pressing the button
again repeats the cycle.
Should the patient's bed be rolled away from the wall, the pillow speaker will simply pull free
from the wall receptacle avoiding any damage.

TAMPER RESISTANT/GERM SHIELD
Germ Shield

: Ideal for psychiatric wards and

germ free environments. Fits lay-in grid
ceiling systems with 15/16" maximum ceiling tee
face. The heavy duty welded extruded aluminum
frame with clear 1/8" thick polycarbonate lens is
fixture to ceiling system sealed with a heavy duty
gasket. Request Folio R40-15 REV. A.

Ballast Compartment accessible by opening
Louver and reflector

Tamper Resistant/Germ Shield

Sequential Switch. 

Suffix: 

SW

Содержание Md.Coffer MDCGWSVA2SB4SB

Страница 1: ...8 0595 631 Airport Road Fall River MA 02720 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish 2007 a Genlyte company Section 8 Folio R40 21 Rev A Wall 12 18 from wall Ceiling 9 6 max mounting height S surface Mount G Exposed T grid ceiling 12 18 from wall Wall angle or T bar by others Wall Accoustical tile by others T bar by others 48 9 6 max ceili...

Страница 2: ...eflected glare from reading material over shoulder illumination No direct glare to patient or visitors Controls light directly onto patient s bed 17 21 23 28 33 6 5 18 22 24 29 35 6 5 17 21 23 28 33 6 5 3 6 12 Wall Bed 12 Lighted Zone 68 85 93 99 100 65 49 31 36 38 42 45 18 12 73 89 99 104 106 68 53 32 38 40 43 47 18 13 68 85 93 99 100 65 49 31 36 38 42 45 18 12 Lighted Zone Illumination at the re...

Страница 3: ... the nurse and control the lighting To control the lighting it should be specified to have a normally open contact switch Pressing this switch on the pillow speaker the first time turns the ambient light on pressed a second time turns the reading light on and the ambient light off pressed a third time turns both the ambient and reading lights on pressed a fourth time turns both lights off Pressing...

Страница 4: ...ble for at least 90 Specifications continued Labels I B E W UL and ULc Listed This product may have a mercury containing lamp Manage in accord with Disposal Laws See www lamprecycle org Options Accessories Access Plates Top wiring access plate is shipped with fixture as standard When access plates are required in advance for wiring convenience specify separately Catalog Number ACP Drywall Kit Orde...

Отзывы: