MD*Coffer 2' x 4' Recessed or Surface
MDCGWSVA2SB4SB
Page 4 of 4
Multi-Function Patient Lighting
Indirect Ambient Light with Perforated Mesh Shield
Job Information
Type:
Lightolier
a Genlyte company
www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 a Genlyte company
Section 8/Folio R40-21 Rev. A
ORDERING INFORMATION
Explanation of Catalog Number. Example: MDCGWSVA2SB4SB120SW
MDC
MD*C
Indirect/
Direct
Recessed or
Surface,
Multi-function
Patient Light
with Perforated
Mesh Shield
G
Ceiling
Type:
Same Unit
May Be Used
For: Grid (lay-in)
Or: Surface
Mounted
2
Lamp
Quantity:
(Ambient/
Reading)
2 Lamps
(Total)
Specifications:
Materials: Chassis parts
are die-formed 20 gauge steel. Louver (examination
light) – aluminum post painted white acrylic.
Reading light
– low iridescence anodized 95% reflective, semi-specular
reflector.
Ambient light
– flat white acrylic contoured steel reflector and perforated
steel mesh shield with white acrylic overlay.
Finish: Cavity
(examination/reading/ambient lights) — flat white acrylic
interior, minimum reflectance 86%. Phosphate undercoating.
Chassis
exterior
— post painted white baked polyester powder.
Louver
(examination
light)
W
=flat white baked enamel 36 cell louver with a virgin acrylic overlay to
enclose all lamps.
VA
=.095" nominal thickness prismatic virgin acrylic overlay.
V
I
=.125" nominal thickness, pattern 12 acrylic lens.
Electrical
: Thermally protected class “P” ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°.
Specifications (continued):
Labels
: I.B.E.W. UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with
Disposal Laws. See: www.lamprecycle.org
Options/Accessories
Access Plates
: Top wiring access plate is shipped with fixture as standard.
When access plates are required in advance for wiring convenience, specify
separately. Catalog Number:
ACP
.
Drywall Kit
: Order Catalog Number:
FK92X4
.
Request Folio
OA30-10 Rev. A
.
Electronic Sequential Switch
(Low Voltage): Switch factory mounted in fix-
ture for ambient and reading light convenience (controlled by pillow switch, by
others). Suffix:
SW
.
Individual Switching
(Low Voltage): Switches mounted to patient's bed for
use with manufacturer's control system (such as Hill-Rom Side Com).
Suffix:
DP
.
9/7 Watt Night Light
: Suffix:
PL
(Lamp not included).
Fusing
: Internal fast-blow fusing. Suffix:
GLR
.
Internal slow-blow fusing. Suffix:
GMF
.
Radio Interference Filter
: To order one RIF per fixture; Suffix:
R
. To order one RIF
per ballast; Suffix:
B
.
Germ Shield
. Order Catalog Number:
MD4CLGS24
.
Electrical/Wiring Options
: Consult factory.
Louver
Overlay/Lens:
VA
= Virgin Acrylic
.095" Nominal
Thickness
Overlay
(standard)
V
I
= .125" Thick
Pattern 12
Acrylic Lens.
Ballast Type:
(Ambient Reading)
<20THD
<10THD
1-2 Lamp Elec. TT5
SB*
I
B*
*
(40 Watt)
1-2 Lamp Elec. TT5
–
PR**
(40 Watt)
LOL Dimming TT5
PB
–
*
*Instant Start Standard
**Program Start
NOTE:
For TT5
UNV
, you must use
I
B
Ballast
Code
Louver/
Lens Frame:
WS
= White Louver
RF
= Regressed
Floating Extruded
Aluminum Door
Frame
Lamp
Quantity
3
= 3 Lamp
4
= 4 Lamp
Options:
Add appropriate
Suffix to Catalog
No. i.e. (
GLR
)
Ballast Type:
(Examination)
<20THD
<10THD
1-3 Lamp Elec. TT5
X3*
I
3*
*
2-2 Lamp Elec. TT5
SB*
I
B*
*
2-2 Lamp Elec. TT5
–
PR**
(40 Watt)
*
LOL Dimming TT5
PB
*
–
*
*Instant Start Standard
**Program Start
NOTE:
For TT5
UNV
, you must use
I
B
Ballast
Code
Voltage:
120 or 277