background image

MD*Coffer 2' x 4' Recessed or Surface 

MDCGWSVA2SB4SB

Page 4 of 4

Multi-Function Patient Lighting

Indirect Ambient Light with Perforated Mesh Shield

Job Information

Type:

Lightolier 

a Genlyte company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 a Genlyte company

Section 8/Folio R40-21 Rev. A

ORDERING INFORMATION

Explanation of Catalog Number.   Example: MDCGWSVA2SB4SB120SW

MDC

MD*C

Indirect/

Direct

Recessed or

Surface,

Multi-function

Patient Light

with Perforated

Mesh Shield

G

Ceiling

Type:

Same Unit

May Be Used

For: Grid (lay-in)

Or: Surface

Mounted

2

Lamp

Quantity:

(Ambient/

Reading)

2 Lamps

(Total)

Specifications:

Materials: Chassis parts

are die-formed 20 gauge steel. Louver (examination

light) – aluminum post painted white acrylic.

Reading light

– low iridescence anodized 95% reflective, semi-specular

reflector.

Ambient light

– flat white acrylic contoured steel reflector and perforated

steel mesh shield with white acrylic overlay.

Finish: Cavity

(examination/reading/ambient lights) — flat white acrylic

interior, minimum reflectance 86%. Phosphate undercoating. 

Chassis

exterior

— post painted white baked polyester powder. 

Louver

(examination

light) 

W

=flat white baked enamel 36 cell louver with a virgin acrylic overlay to

enclose all lamps. 

VA

=.095" nominal thickness prismatic virgin acrylic overlay.

V

I

=.125" nominal thickness, pattern 12 acrylic lens.

Electrical

: Thermally protected class “P” ballast C.B.M. approved, non PCB. If

K.O. is within 3" of ballast, use wire suitable for at least 90°.

Specifications (continued):

Labels

: I.B.E.W. UL and ULc Listed.

This product may have a mercury containing lamp. Manage in accord with
Disposal Laws. See: www.lamprecycle.org

Options/Accessories

Access Plates

: Top wiring access plate is shipped with fixture as standard.

When access plates are required in advance for wiring convenience, specify
separately. Catalog Number: 

ACP

.

Drywall Kit

: Order Catalog Number: 

FK92X4

.

Request Folio 

OA30-10 Rev. A

.

Electronic Sequential Switch

(Low Voltage): Switch factory mounted in fix-

ture for ambient and reading light convenience (controlled by pillow switch, by
others). Suffix: 

SW

.

Individual Switching

(Low Voltage): Switches mounted to patient's bed for

use with manufacturer's control system (such as Hill-Rom Side Com).
Suffix: 

DP

.

9/7 Watt Night Light

: Suffix: 

PL

(Lamp not included).

Fusing

: Internal fast-blow fusing. Suffix: 

GLR

.

Internal slow-blow fusing. Suffix: 

GMF

.

Radio Interference Filter

: To order one RIF per fixture;  Suffix: 

R

. To order one RIF

per ballast; Suffix: 

B

.

Germ Shield

. Order Catalog Number: 

MD4CLGS24

.

Electrical/Wiring Options

: Consult factory.

Louver

Overlay/Lens:

VA

= Virgin Acrylic 

.095" Nominal
Thickness
Overlay
(standard)

V

I

= .125" Thick

Pattern 12
Acrylic Lens.

Ballast Type:

(Ambient Reading)

<20THD

<10THD

1-2 Lamp Elec. TT5

SB*

I

B*

*

(40 Watt)

1-2 Lamp Elec. TT5

PR**

(40 Watt)

LOL Dimming TT5

PB

*

*Instant Start Standard

**Program Start

NOTE:

For TT5 

UNV

, you must use 

I

B

Ballast

Code

Louver/

Lens Frame:

WS

= White Louver

RF

= Regressed

Floating Extruded
Aluminum Door
Frame

Lamp

Quantity

3

= 3 Lamp

4

= 4 Lamp

Options:

Add appropriate

Suffix to Catalog

No. i.e. (

GLR

)

Ballast Type:

(Examination)

<20THD

<10THD

1-3 Lamp Elec. TT5

X3*

I

3*

*

2-2 Lamp Elec. TT5

SB*

I

B*

*

2-2 Lamp Elec. TT5

PR**

(40 Watt)

*

LOL Dimming TT5

PB

*

*

*Instant Start Standard

**Program Start

NOTE:

For TT5 

UNV

, you must use 

I

B

Ballast

Code

Voltage:

120 or 277

Содержание Md.Coffer MDCGWSVA2SB4SB

Страница 1: ...8 0595 631 Airport Road Fall River MA 02720 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish 2007 a Genlyte company Section 8 Folio R40 21 Rev A Wall 12 18 from wall Ceiling 9 6 max mounting height S surface Mount G Exposed T grid ceiling 12 18 from wall Wall angle or T bar by others Wall Accoustical tile by others T bar by others 48 9 6 max ceili...

Страница 2: ...eflected glare from reading material over shoulder illumination No direct glare to patient or visitors Controls light directly onto patient s bed 17 21 23 28 33 6 5 18 22 24 29 35 6 5 17 21 23 28 33 6 5 3 6 12 Wall Bed 12 Lighted Zone 68 85 93 99 100 65 49 31 36 38 42 45 18 12 73 89 99 104 106 68 53 32 38 40 43 47 18 13 68 85 93 99 100 65 49 31 36 38 42 45 18 12 Lighted Zone Illumination at the re...

Страница 3: ... the nurse and control the lighting To control the lighting it should be specified to have a normally open contact switch Pressing this switch on the pillow speaker the first time turns the ambient light on pressed a second time turns the reading light on and the ambient light off pressed a third time turns both the ambient and reading lights on pressed a fourth time turns both lights off Pressing...

Страница 4: ...ble for at least 90 Specifications continued Labels I B E W UL and ULc Listed This product may have a mercury containing lamp Manage in accord with Disposal Laws See www lamprecycle org Options Accessories Access Plates Top wiring access plate is shipped with fixture as standard When access plates are required in advance for wiring convenience specify separately Catalog Number ACP Drywall Kit Orde...

Отзывы: