Lightolier
a Genlyte company
www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 Genlyte Group LLC • C1007
Job Information
Type:
Lytecaster
®
Performance Recessed CFL Downlighting
2001L
Page 2 of 2
3 ¾" Aperture Vertical Wet Location, Compact Fluorescent, Performance Series,
Reflector Trim
18W TRIPLE TUBE LAMP
, LUMEN RATING = 1200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM WITH FRESNEL LENS
18W TRIPLE TUBE LAMP
, LUMEN RATING = 1200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM WITH OPAL LENS
18W TRIPLE TUBE LAMP
, LUMEN RATING = 1200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM WITH CLEAR LENS
COEFFICIENTS OF UTILIZATION
Ceiling
80%
70%
50%
30%
Wall
70 50 30 10 50 10 50 10 50 10
0
RCR
Zonal Cavity Method - Effective Floor Reflectance = 20%
Room
Cavity
Ratio
0 36 36 36 36 35 35 34 34 32 32 30
1 34 33 32 31 32 31 31 30 30 29 27
2 32 30 28 27 29 26 28 27 26 27 24
3 29 27 25 23 26 23 26 23 25 22 21
4 27 24 22 20 24 20 23 20 22 20 19
5 25 22 20 18 22 18 21 18 20 17 17
6 24 20 18 16 20 16 19 16 19 16 15
7 22 18 16 14 18 14 18 14 17 14 13
8 20 17 14 13 17 13 16 13 16 13 12
9 19 15 13 12 15 12 15 11 15 11 11
10 18 14 12 11 14 10 14 10 14 10 10
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 22.0
1
50
100
150
200
60˚
30˚
SC = 1.6
CERTIFIED TEST REPORT NO. 3349FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**
ZONAL LUMENS AND PERCENTAGES
Zone
Lumens %Lamp
%Fixt
0-30
139.25
11.6
38.1
0-40
232.59
19.4
63.6
0-60
353.98
29.5
96.8
0-90
365.87
30.5
100
90-120
0
0
0
90-130
0
0
0
90-150
0
0
0
90-180
0
0
0
0-180 365.87
30.5
100
** Efficiency = 30.5%**
ZONAL LUMEN SUMMARY
Zone
Lumens
0-10
13.37
10-20
46.72
20-30
79.16
30-40
93.34
40-50
79.65
50-60
41.74
60-70
10.17
70-80
1.58
80-90
.14
90-100
0
100-110
0
110-120
0
120-130
0
130-140
0
140-150
0
150-160
0
160-170
0
170-180
0
CANDLEPOWER SUMMARY
Angle
0˚ CP
0
129
5
135
10
150
15
165
20
173
25
172
30
165
35
150
40
131
45
104
50
74
55
46
60
24
65
8
70
3
75
1
80
1
85
0
90
0
COEFFICIENTS OF UTILIZATION
Ceiling
80%
70%
50%
30%
Wall
70 50 30 10 50 10 50 10 50 10
0
RCR
Zonal Cavity Method - Effective Floor Reflectance = 20%
Room
Cavity
Ratio
0 35 35 35 35 34 34 33 33 31 31 30
1 33 32 31 30 31 30 29 28 27 27 26
2 31 29 27 26 28 25 27 25 26 24 23
3 28 26 24 22 25 22 24 22 24 21 20
4 26 23 21 19 23 19 22 19 21 19 18
5 24 21 19 17 21 17 20 17 20 17 16
6 23 19 17 15 19 15 18 15 18 15 14
7 21 17 15 13 17 13 17 13 16 13 13
8 20 16 14 12 16 12 13 15 13 12 11
9 18 15 12 11 15 11 14 11 14 11 10
10 17 14 11 10 13 10 13 10 13 10 9
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 22.0
1
50
100
150
200
60˚
30˚
SC = 1.4
CERTIFIED TEST REPORT NO. 3348FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**
ZONAL LUMENS AND PERCENTAGES
Zone
Lumens %Lamp
%Fixt
0-30
131.6
11
37
0-40
217.11
18.1
61.1
0-60
333.76
27.8
93.9
0-90
355.26
29.6
100
90-120
0
0
0
90-130
0
0
0
90-150
0
0
0
90-180
0
0
0
0-180
355.26
29.6
100
** Efficiency = 29.6%**
ZONAL LUMEN SUMMARY
Zone
Lumens
0-10
14.54
10-20
44.62
20-30
72.45
30-40
85.51
40-50
73.84
50-60
42.8
60-70
16.63
70-80
4.73
80-90
.14
90-100
0
100-110
0
110-120
0
120-130
0
130-140
0
140-150
0
150-160
0
160-170
0
170-180
0
CANDLEPOWER SUMMARY
Angle
0˚ CP
0
151
5
152
10
154
15
157
20
159
25
158
30
151
35
138
40
119
45
97
50
71
55
47
60
28
65
16
70
9
75
4
80
1
85
0
90
0
1
50
100
150
200
60˚
30˚
SC = 1.1
CERTIFIED TEST REPORT NO. 3350FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**
COEFFICIENTS OF UTILIZATION
Ceiling
80%
70%
50%
30%
Wall
70 50 30 10 50 10 50 10 50 10
0
RCR
Zonal Cavity Method - Effective Floor Reflectance = 20%
Room
Cavity
Ratio
0 31 31 31 31 30 30 29 29 28 28 26
1 29 28 27 26 27 26 26 25 25 24 23
2 27 25 23 22 24 22 23 21 23 21 20
3 24 22 20 19 22 19 21 18 20 18 17
4 23 20 18 16 20 16 19 16 18 16 15
5 21 18 16 14 18 14 17 14 17 14 13
6 19
6 14 13 16 13 16 12 15 12
12
7 18 15 13 11 15 11 14 11 14 11 11
8 17 14 12 10 13 10 13 10 13 10 9
9 16 13 11 9 12 9 12 9 12 9
9
10 15 12 10 8 12 8
11 8
11 8
8
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 22.0
ZONAL LUMENS AND PERCENTAGES
Zone
Lumens %Lamp
%Fixt
0-30
111.65
9.3
35.8
0-40
175.81
14.7
56.4
0-60
279.09
23.3
89.6
0-90
311.48
26
100
90-120
0
0
0
90-130
0
0
0
90-150
0
0
0
90-180
0
0
0
0-180
311.48
26
100
** Efficiency = 26%**
ZONAL LUMEN SUMMARY
Zone
Lumens
0-10
14.23
10-20
39.88
20-30
57.54
30-40
64.16
40-50
58.87
50-60
44.41
60-70
25.17
70-80
7.09
80-90
.14
90-100
0
100-110
0
110-120
0
120-130
0
130-140
0
140-150
0
150-160
0
160-170
0
170-180
0
CANDLEPOWER SUMMARY
Angle
0˚ CP
0
151
5
150
10
147
15
142
20
134
25
125
30
115
35
103
40
90
45
76
50
63
55
50
60
37
65
25
70
15
75
6
80
1
85
0
90
0