background image

Lowprofile CD7

Sleek and compact,
Lowprofile CD7
makes a dynamic
design statement
used individually 
or in graceful 
linear runs.

When suspended, the Lowprofile

CD7 appears to float in the

environment. The bold design 

and full range of functions make

the Lowprofile CD7 ideal for 

large open areas as well as

contained spaces. Its attractive

housing is made up of two 

die cast end caps connected by 

high quality aluminum extrusions.

Light shielding is by means of 

a high performance semi-specular

parabolic louver or acrylic

prismatic lens.

Profiles

Architectural 

Round

Square

Recessed

Cove

Accent

Custom

Lightolier Lighting Systems

Lightolier Lighting Systems are modular lighting systems that offer a wide selection of
geometric shapes, architectural profiles, scales and finishes.

These quality materials combined with a highly efficient reflector

system, make the Lowprofile CD7 ideal for settings requiring

generous overall illumination as well as those where a soft ambi-

ence is to be combined with controlled task lighting. The Lowprofile 

is designed to provide both superior photometric performance in

either indirect/direct or direct light distributions. Whether stem

suspended, cable suspended or surface mounted, the Lowprofile

CD7 provides high performance in an attractive package.

Lighting Systems

Specifications

Housing: 

Extruded aluminum. Die-cast end cap mechanically attached with no exposed fas-

teners. Concealed access holes in end plate for through wiring.

Lamping: 

One, two or three T8 fluorescent lamps, as specified. Provided by others.

Reflector:

Accurate parabolic-shaped, die-formed semi-specular anodized aluminum reflector.

Shielding: 

Louver or Lens as specified. Louver: parabolic-shaped, die formed semi-specular

anodized aluminum. Provides low brightness in lengthwise and crosswise views with 
37 degree shielding lengthwise. Concealed latches operate from either side. Lens: extruded
100% acrylic clear prismatic lens.

Electrical

Specify 120 volt or 277 volt. 3 conductor, 12 gauge wire. Color-coded quick 
connectors allow ease of connection for joiner modules. For special circuiting, 
consult factory. Rapid start, HPF, class “P” thermally protected. PowerSpec

®

HDF

dimming ballast is available.

Mountings 

Cable Suspension

(not shown) – 4 1/2" diameter flat canopy finished enamel white,

1/16" diameter stainless steel aircraft cable adjustable up to 36", adjustable cable
gripper.

Stem Mounting

(not shown) – 4 1/2" diameter flat canopy finished enamel white.

1/2" diameter stem. Chrome plate or white finish. Can be cut to length on job. 
Self-aligning swivel provides adjustability up to 38 degrees. The stem assembly shall
meet or exceed the requirements set forth in the State of California Uniform Building
Code for suspended lighting fixtures installed in seismic zone four. 

Surface and wall mounting 

(not shown) – consult factory.

Finish

Powder coated baked white enamel. Custom colors available, 
consult factory.

Options & Accessories

Fusing, two circuit switching, emergency batteries available – consult factory.

Labels

UL, ULc and IBEW.

Total

Ballast 

Style Type

Mounting Length

Lamps

Color

& Voltage

Individual Fixtures

1.  Order number of FIXTURES (fixture

comes with end caps, mountings 
and power feeds).

Continuous Rows

1. Determine run length.

2.  Order appropriate number of 

FIXTURES to complete the run.

Fixtures can be bolted together and
through wired to complete long runs.

How to specify and order

CD7

WH

How to Specify

Style

Type

Lamps

CD7

1 = Direct Louver

1 = 1 lamp 4’

2 = Direct Lens

2 = 2 lamp 4’ or 1 lamp 8’

3 = Direct/Indirect Louver

3 = 3 lamp 4’ (T8 only)

4 = Direct/Indirect Lens

4 = 2 lamp 8’

6 = 3 lamp 8’ (T8 only)

Example: CD713

1

= Direct Louver

2

= Direct Lens

= Direct/Indirect

Louver

= Direct/Indirect

Lens

= Surface

2

= Cable

= Stem

= Wall

= 4 feet

= 8 feet

= 1 Lamp 

per fixture 
(4' fixture only)

2

= 2 Lamps

per fixture 
(2 lamp cross

section per 4')

(1 lamp cross

section per 8')

= 3 Lamps 

per fixture

(4' fixture only)

= 4 Lamps 

per fixture 
(2 lamp cross

section 8' only)

= 6 Lamps 

per fixture 
(3 lamp cross

section 8' only)

White

Blank 

= T12 Magnetic

120v

= T12 Magnetic

277v

E1 

= T12 Electronic 

120v

E2 

= T12 Electronic 

277v

E81 

= T8 Electronic 

120v

E82 

= T8 Electronic 

277v

HD1 

= T8 PowerSpec 

HDF Dimming 
120v

HD2 

= T8 PowerSpec 

HDF Dimming 
277v

M71 

= T8 Electronic 

Dimming Ballast 
120v

M72 

= T8 Electronic 

Dimming Ballast 
277v

How to Order

Example: CD71283WHE1

2

1

4

3

3

1

/

4

"

9"

3 1/4"

9"

CD7 Direct Louver

Report No. LRL 699-4B

CD7-1

: 1 lamp T8 

67.7% efficiency, 0% 

100% 

CD7-2

: 2 lamp T8

53.0% efficiency, 0% 

100% 

CD7-3

: 3 lamp T8

47.5% efficiency, 0% 

100% 

All performance data shown are for 
2 lamp T8. For other lamping options
please refer to spec sheets.

Coefficients of Utilization 

% Wall Reflectance

50

30

10

0

63

63

63

1

58

56

55

2

53

54

49

3

49

46

44

4

45

41

39

5

41

38

35

6

38

34

31

7

34

31

28

8

31

28

25

9

29

25

22

10

25

21

19

80%

Ceiling Reflectance

20%

Floor Reflectance

Room Cavity Ratio

Application Data

Fixture Spacing

Footcandles

Watt /Sq Ft

50’ x 70’ x 8.5’ Space

8’ x 8’ (64 sq ft /fixture)

35

1.0

8’ x 10’ (80 sq ft /fixture)

17

0.8

12’ x 16’ x 8.5’ Space

6’ x 8’ (48 sq ft /fixture)

34

1.2

8’ x 8’ x 8.5’ Space

8’ x 8’ (64 sq ft /fixture)

19

1.0

Reflectances: 80% Ceiling, 50% Wall, 20% Floor

Light Loss Factor = .75 (.88 BF x 8.5)

3 1/4"

9"

CD7 Direct Lens

Report No. LRL 282-5A

CD7-4

: 1 lamp T8 

53.9% efficiency, 0% 

100% 

CD7-5

: 2 lamp T8 

45.7% efficiency, 0% 

100% 

CD7-6

: 3 lamp T8

49.3% efficiency, 0% 

100% 

All performance data shown are for 
2 lamp T8. For other lamping options
please refer to spec sheets.

Coefficients of Utilization 

% Wall Reflectance

50

30

10

0

54

54

54

1

49

48

47

2

45

43

41

3

42

39

37

4

38

35

33

5

35

32

30

6

32

29

27

7

30

27

24

8

27

24

22

9

25

22

20

10

22

19

17

80%

Ceiling Reflectance

20%

Floor Reflectance

Room Cavity Ratio

Application Data

Fixture Spacing

Footcandles

Watt /Sq Ft

50’ x 70’ x 8.5’ Space

8’ x 8’ (64 sq ft /fixture)

38

1.0

8’ x 10’ (80 sq ft /fixture)

18

0.8

12’ x 16’ x 8.5’ Space

6’ x 8’ (48 sq ft /fixture)

36

1.2

8’ x 8’ x 8.5’ Space

8’ x 8’ (64 sq ft /fixture)

21

1.0

Reflectances: 80% Ceiling, 50% Wall, 20% Floor

Light Loss Factor = .75 (.88 BF x 8.5)

3 1/4"

9"

CD7 Direct/Indirect Louver

Report No. LRL 1282-5A

CD7-7

: 1 lamp T8 

80.3% efficiency, 53.5% 

46.5% 

CD7-8

: 2 lamp T8 

78.9% efficiency, 55.8% 

44.2% 

CD7-9

: 3 lamp T8

79.9% efficiency, 55.3% 

44.7% 

All performance data shown are for 
2 lamp T8. For other lamping options please
refer to spec sheets.

Coefficients of Utilization 

% Wall Reflectance

50

30

10

1

74

72

69

2

66

62

59

3

59

54

50

4

53

48

43

5

48

42

38

6

43

37

33

7

39

33

29

8

35

29

25

9

32

26

22

10

28

22

19

80%

Ceiling Reflectance

20%

Floor Reflectance

Room Cavity Ratio

Application Data

Ceiling

Susp.

Illum. Max.

Lum.

W/

Height

Dist.

(FC)

Lum.

Ratio Sq Ft

50' x 70' Space

10'

9' 18'

72

123

8.3

1.5

12'

10.5" 24"

60

92

7.4

1.3

12’ x 16’ Space

8'

9' 18"

71

119

6.9

2.0

8’ x 8’ x 5’ Cubicle R = 50%

12'

10.5'

24"

71

90

8.6

2.0

Reflectances: 80% Ceiling, 50% Wall, 20% Floor

Light Loss Factor = .75 (.88 BF x 8.5)

3 1/4"

9"

CD7 Direct/Indirect Lens

Report No. LRL 282-5B

CD7-10

: 1 lamp T8

84.1% efficiency, 57.8% 

42.2% 

CD7-11

: 2 lamp T8

78% efficiency, 54.6% 

45.4% 

CD7-12

: 3 lamp T8

83.6% efficiency, 54.6% 

45.4% 

All performance data shown are for 
2 lamp T8. For other lamping options please
refer to spec sheets.

Coefficients of Utilization 

% Wall Reflectance

50

30

10

0

83

83

83

1

73

71

68

2

66

62

58

3

59

54

50

4

53

48

43

5

48

42

38

6

43

38

34

7

39

34

30

8

36

30

26

9

33

27

24

10

29

24

20

80%

Ceiling Reflectance

20%

Floor Reflectance

Room Cavity Ratio

Application Data

Ceiling

Susp.

Illum. Max.

Lum.

W/

Height

Dist.

(FC)

Lum.

Ratio Sq Ft

50' x 70' Space

10'

9' 18'

71

123

8.4

1.5

12'

10.5" 24"

59

92

7.5

1.3

12’ x 16’ Space

8'

9' 18"

70

119

7.0

2.0

8’ x 8’ x 5’ Cubicle R = 50%

12'

10.5'

24"

70

90

8.7

2.0

Reflectances: 80% Ceiling, 50% Wall, 20% Floor

Light Loss Factor = .75 (.88 BF x 8.5)

Luminaire Row Spacing

Luminaire Row Spacing

400

800

1200

0

15˚

90˚

45˚

400

800

1200

0

15˚

90˚

45˚

400

400

800

800

0

15˚

45˚

150˚

90˚

120˚

400

400

800

800

0

15˚

90˚

180˚

150˚

120˚

45˚

Отзывы: