background image

Job Information 

Type:

"JSQPSU3PBE'BMM3JWFS."t t'BY 

We reserve the right to change details of design, materials and finish.

XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #

Lighting Systems

 SORA-5

1BHFPG

-JHIU51FS'PPU /PNJOBM4FDUJPO

80%

70%

50%

70 50

30

70

50

30

50 30 10

0

80 80

80

71

71

71

54 54 54

1

71 66

63

62

59

56

44 42 40

2

63 57

52

45

50

46

38 35 32

3

57 49

43

50

44

38

33 29 26

4

52 43

37

46

38

33

29 25 21

5

48 38

32

42

34

28

25 21 18

6

44 34

27

38

30

24

23 18 15

7

40 30

24

35

27

21

20 16 13

8

37 27

21

33

24

19

18 14 12

9

34 25

19

30

22

17

17 13 10

10

32 23

17

28

20

15

15 12 9

CANDLEPOWER

ZONE

0

22

45

67

90

DEG.

CANDELAS

180

563 563 563 563 563

175

564 564 563 561 560

165

548 549 552 554 553

155

537 538 527 511 506

145

554 546 503 448 442

135

556 535 480 1264 1299

125

546 519 1087 1754 1968

115

515 701 1546 1991 2106

105

438 852 1488 1770 1851

95

156 645 873 975 986

90

2 221 406 484 516

85

23 216 402 495 525

75

73 198 412 521 552

65

107 183 350 470 511

55

134 172 288 384 421

45

156 179 245 311 338

35

182 193 222 261 279

25

204 209 223 238 243

15

216 218 222 227 229

5

222 222 222 222 221

0

221 221 221 221 221

Performance

COEFFICIENTS OF UTILIZATION

% EFFECTIVE CEILING CAVITY REFLECTANCE

REPORT NO.: ITL54090
LAMPS: 2-F54T5
LUMENS: 5000
EFFICIENCY: 78.9%
CAT NO.: S254CW4WH

CANDLEPOWER CURVE

WALL REFLECTANCE

Fixture Lengths & Mounting Locations

51-5/8”

Mounting Accessories

Power Feed Cable End Set

Distance is fro

m

 the ceiling

line to the top of the lu

m

i-

naire housing.

36” Platinu

m

SECW36SC

36” White: 

SECW36WH

Stem End Set

Distance is fro

m

 the ceiling

line to the top of the lu

m

i-

naire housing.

30” Platinu

m

SESW3ØSC

30” White: 

SESW3ØWH

Intermediate Cable

Distance is fro

m

 the ceiling

line to the top of the lu

m

i-

naire housing.

36” Platinu

m

:

SICW36SC

36” White: 

SICW36WH

Notes:

1. Suspended wing lu

m

inaires can be continuously row 

m

ounted longer 

than 8’ (243.84c

m

) (but all fixtures 

m

ust be 4-foot no

m

inal units).

2. The electrical capacity of power cords cannot be exceeded.
3. Non-wing lu

m

inaires can be added to the continuous rows if desired 

Consult factory for details.

4. 30” (76.20c

m

) is the 

m

ini

m

u

m

 reco

mm

ended 

m

ounting distance

when designing with Wing lu

m

inaires.

Intermediate Stem

Distance is fro

m

 the ceiling 

line to the top of the lu

m

i-

naire housing.

30” Platinu

m

SISW3ØSC

30” White: 

SISW3ØWH

Intermediate Cable/Cord

Distance is fro

m

 the ceiling

line to the top of the lu

m

i-

naire housing.

36” Platinu

m

SIPW36SC

36” White: 

SIPW36WH

4-foot

8-foot

20% FLOOR CAVITY REFLECTANCE

DISTRIBUTION

Zone

Lu

m

ens

% La

m

p %  Lu

m

inaire

0-90

1855

18.5

23.5

90-180

6032

60.3

76.5

0-180

7887

78.9

100.0

52-1/4” 

51-5/8”

103-3/4” 

51-5/8” 

Отзывы: