Lighting Systems
Baselyte-BSL11
Page 2 of 8
2 Light T8 Semi-Indirect
Lightolier
a Genlyte Company
www.lightolier.com
63 Airport Road, Fall River, MA 02720 • (508) 679-83 • Fax (508) 674-470
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.
Job Information
Type:
Performance
Candlepower Curve
Candlepower Summary
Coefficients of Utilization
Module Lengths & Mounting Distances
Joiner
BSLESW
= suspended standard white
Dust Cover
End Set
BSLJS
= suspended joiner
BSLDCS
= 4’ suspended dust cover
System Components & Accessories
Run Configuration
Run
Length
4’
Module
8’
Module
2’
Module
Joiner
End Set
Mount
Power
Mount*
4’ run
8’ run
2’ run
6’ run
2
2
20’ run
2
24’ run
2
2
28’ run
2
2
3
32’ run
2
2
3
Report No:
99005
Lamps:
F32T8
Lumens per Lamp:
2950
Efficiency:
80.0%
Up:
94.3%
Down:
5.7%
-ODULE,ENGTH
-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
@
@
@
Zonal Lumen Summary
ZONE
LUMENS %BARE LAMP %LUMINAIRE
Candlepower Summary
ZONE
CANDLEPOWER
DEG.
0
22.5
45
67.5
90
180
1268
1268
1268
1268
1268
175
1262
1261
1258
1255
1255
165
1218
1210
1217
1224
1226
155
1135
1130
1151
1166
1171
145
1017
1018
1052
1083
1095
135
863
873
933
993
1018
125
681
707
810
914
943
115
484
531
691
777
802
105
271
371
517
578
601
95
58
153
204
197
211
90
3
11
22
31
34
85
6
9
17
26
30
75
11
14
27
37
42
65
15
24
37
48
53
55
25
34
48
58
62
45
39
45
57
65
69
35
54
56
64
72
75
25
66
68
72
76
78
15
76
77
78
80
81
5
81
81
82
82
82
0
82
82
82
82
82
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80
70
50
% WALL REFLECTANCE
50
30
10
50
30
10
50
30
10
0
77
77
77
66
66
66
47
47
47
1
66
64
61
57
55
53
40
39
37
2
58
53
49
50
46
43
35
33
31
3
51
45
41
44
39
36
31
28
26
4
45
39
34
38
34
30
27
24
22
5
39
33
29
34
29
25
24
21
18
6
35
29
25
30
25
22
21
18
16
7
31
25
21
27
22
19
19
16
13
8
28
22
18
24
20
16
17
14
12
9
25
20
16
22
17
14
16
12
10
10 23
18
14
20
15
12
14
11
9
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP
%LUMINAIRE
0-90
90-180
0-180
4709
4439
270
5.7
94.3
100.0
4.6
75.2
79.8
Note
: Shaded area indicates locations of emergency sections (emergency wiring
controls all lamps or optional battery pack controls one or two lamps).
*Note
: Additional power mounts may be required for some runs with T5 HO
lamping options, longer runs, and runs with wiring options that are more complex.
Please consult factory for assistance.
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80
70
50
% WALL REFLECTANCE
50
30
10
50
30
10
50
30
10
0
77
77
77
66
66
66
47
47
47
1
66
64
61
57
55
53
40
39
37
2
58
53
49
50
46
43
35
33
31
3
51
45
41
44
39
36
31
28
26
4
45
39
34
38
34
30
27
24
22
5
39
33
29
34
29
25
24
21
18
6
35
29
25
30
25
22
21
18
16
7
31
25
21
27
22
19
19
16
13
8
28
22
18
24
20
16
17
14
12
9
25
20
16
22
17
14
16
12
10
10 23
18
14
20
15
12
14
11
9
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP
%LUMINAIRE
0-90
90-180
0-180
4709
4439
270
5.7
94.3
100.0
4.6
75.2
79.8