Calculite
®
HID Surface Cylinder
CACEX
Page 1 of 2
T4.5 Ceramic Metal Halide, Expo
CEILING
80%
70%
50%
30%
WALL
70 50 30 10
50 10
50 10
50 10
0
RCR
0
.50 .50 .50 .50
.49 .49
.47 .47
.45 .45
.42
1
.47 .45 .44 .42
.44 .42
.42 .40
.41 .39
.37
2
.44 .41 .39 .37
.41 .37
.39 .36
.38 .35
.34
3
.41 .38 .35 .33
.37 .33
.36 .33
.35 .32
.31
4
.39 .35 .33 .31
.35 .30
.34 .30
.33 .30
.29
5
.37 .33 .30 .28
.33 .28
.32 .28
.31 .27
.26
6
.35 .31 .28 .26
.31 .26
.30 .26
.29 .26
.25
7
.33 .29 .26 .24
.29 .24
.28 .24
.28 .24
.23
8
.32 .27 .25 .23
.27 .23
.27 .23
.26 .22
.22
9
.30 .26 .23 .21
.26 .21
.25 .21
.25 .21
.20
10 .29 .24 .22 .20
.24 .20
.24 .20
.23 .20
.19
LUMINAIRE INPUT WATTS = 23
ANGLE MEAN CP
LUMS.
0
684
5
670
63
10
629
15
557
157
20
465
25
360
168
30
263
35
183
117
40
115
45
65
57
50
49
55
48
43
60
46
65
44
43
70
41
75
37
39
80
33
85
29
32
90
25
20W T4.5
G.E. CERAMIC MH, LUMEN RATING = 1700 LMS., AROMAT 20W ELECTRONIC BALLAST
Coefficients of Utilization
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45
5075
55
4571
65
5720
75
7871
85
18528
** EFFICIENCY = 42.3% **
CERTIFIED TEST REPORT NO. 2616FR, DATE: MAY 10, 2004
SC =.8
COMPUTED BY LSI PROGRAM **TEST-LITE**
CANDLEPOWER DISTRIBUTION
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30
387
22.79
53.92
0-40
504
29.68
70.2
0-60
604
35.54
84.08
0-90
718
42.27
100
40-90
214
12.6
29.8
60-90
114
6.73
15.92
90-180
0
0
0
0-180
718
42.27
100
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
30°
60°
350
175
525
700
CEILING
80%
70%
50%
30%
WALL
70 50 30 10
50 10
50 10
50 10
0
RCR
0
.59 .59 .59 .59
.58 .58
.55 .55
.53 .53
.50
1
.55 .53 .51 .50
.52 .49
.50 .47
.48 .46
.44
2
.52 .49 .46 .44
.48 .43
.46 .42
.44 .41
.39
3
.49 .45 .42 .39
.44 .39
.43 .38
.41 .38
.36
4
.46 .42 .38 .36
.41 .36
.40 .35
.39 .35
.33
5
.43 .39 .35 .33
.38 .33
.37 .32
.36 .32
.31
6
.41 .36 .33 .30
.36 .30
.35 .30
.34 .30
.29
7
.39 .34 .31 .28
.34 .28
.33 .28
.32 .28
.27
8
.37 .32 .29 .26
.31 .26
.31 .26
.30 .26
.25
9
.35 .30 .27 .25
.30 .25
.29 .24
.29 .24
.23
10 .33 .28 .25 .23
.28 .23
.28 .23
.27 .23
.22
LUMINAIRE INPUT WATTS = 44
ANGLE MEAN CP
LUMENS
0
1461
5
1441
137
10
1377
15
1243
349
20
1056
25
832
386
30
617
35
435
276
40
269
45
147
131
50
115
55
115
102
60
111
65
104
103
70
95
75
85
89
80
73
85
62
68
90
50
39W T4.5
PHILIPS CERAMIC MH, LUMEN RATING = 3300 LMS., AROMAT 39W ELECTRONIC BALLAST
Coefficients of Utilization
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45
11431
55
11051
65
13572
75
17969
85
39439
** EFFICIENCY = 49.7% **
CERTIFIED TEST REPORT NO. 2335FR, DATE: APRIL 19, 2004
SC = .8
COMPUTED BY LSI PROGRAM **TEST-LITE**
CANDLEPOWER DISTRIBUTION
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30
871
26.41
53.12
0-40
1147
34.77
69.93
0-60
1380
41.85
84.18
0-90
1640
49.71
100
40-90
493
14.95
30.07
60-90
259
7.86
15.82
90-180
0
0
0
0-180
1640
49.71
100
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
30°
60°
750
375
1,125
1,500