** EFFICIENCY = 73.7% **
CERTIFIED TEST REPORT NO. 2456FR, DATE: FEB 13,
SC = .8
2004 COMPUTED BY LSI PROGRAM **TEST-LITE**
Calculite
®
HID Downlight
C6P38MH
Page 1 of 2
6" Aperture, PAR38 Ceramic MH
Lightolier
a Genlyte Thomas Company
www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504
Job Information
Type:
70W PAR38 FLOOD
MH PHILIPS 3K , LUMEN RATING = 4800 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH TRIM
5,000
10,000
15,000
20,000
30°
60°
ANGLE
MEAN CP
LUMENS
0
20134
5
17728
1622
10
12396
15
6288
1901
20
1851
25
460
337
30
140
35
64
47
40
29
45
10
9
50
0
55
0
0
60
0
65
0
0
70
0
75
0
0
80
0
85
0
0
90
0
ZONAL LUMENS AND PERCENTAGES
ZONE
LUMENS % LAMP %LUMINAIRE
0-30
3860
80.42
98.57
0-40
3906
81.39
99.76
0-60
3916
81.59
100
0-90
3916
81.59
100
40-90
9
0.19
0.24
60-90
0
0
0
90-180
0
0
0
0-180
3916
81.59
100
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE
MEAN CD/SQ M
45
479
55
0
65
0
75
0
85
0
** EFFICIENCY = 81.6% **
CERTIFIED TEST REPORT NO. 2453FR, DATE: FEB 12, 2004
SC = .4
COMPUTED BY LSI PROGRAM **TEST-LITE**
CEILING
80%
70%
50%
30%
WALL
70
50
30
10
50
10
50
10
50
10
0
RCR
0
.97
.97
.97
.97
.95
.95
.91
.91
.87
.87
.82
1
.95
.93
.92
.91
.92
.89
.88
.87
.85
.84
.80
2
.92
.90
.88
.86
.89
.86
.86
.84
.84
.82
.79
3
.90
.88
.85
.84
.87
.83
.85
.82
.83
.81
.79
4
.89
.86
.83
.81
.85
.81
.83
.80
.82
.79
.78
5
.87
.84
.81
.79
.83
.79
.82
.78
.80
.78
.76
6
.86
.82
.80
.78
.82
.78
.81
.77
.80
.77
.76
7
.84
.80
.78
.76
.80
.76
.79
.76
.78
.75
.74
8
.83
.79
.77
.75
.78
.75
.78
.75
.77
.74
.73
9
.82
.78
.76
.74
.77
.74
.77
.73
.76
.73
.73
10
.80
.76
.74
.72
.76
.72
.76
.72
.75
.72
.71
LUMINAIRE INPUT WATTS = 78.0
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
100W PAR38 FLOOD
MH PHILIPS 3K , LUMEN RATING = 6800 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH TRIM
6,500
13,000
19,500
26,000
30°
60°
ANGLE
MEAN CP
LUMENS
0
26152
5
24195
2202
10
17741
15
9134
2760
20
2934
25
793
544
30
182
35
78
57
40
29
45
4
7
50
0
55
0
0
60
0
65
0
0
70
0
75
0
0
80
0
85
0
0
90
0
ZONAL LUMENS AND PERCENTAGES
ZONE
LUMENS % LAMP %LUMINAIRE
0-30
5505
80.97
98.84
0-40
5563
81.82
99.87
0-60
5570
81.92
100
0-90
5570
81.92
100
40-90
7
0.11
0.13
60-90
0
0
0
90-180
0
0
0
0-180
5570
81.92
100
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE
MEAN CD/SQ M
45
221
55
0
65
0
75
0
85
0
** EFFICIENCY = 81.9% **
CERTIFIED TEST REPORT NO. 2455FR, DATE: FEB 13, 2004
SC = .4
COMPUTED BY LSI PROGRAM **TEST-LITE**
CEILING
80%
70%
50%
30%
WALL
70
50
30
10
50
10
50
10
50
10
0
RCR
0
.98
.98
.98
.98
.95
.95
.91
.91
.87
.87
.82
1
.95
.94
.92
.91
.92
.90
.89
.87
.86
.84
.81
2
.93
.90
.89
.87
.89
.86
.86
.84
.84
.82
.80
3
.91
.88
.86
.84
.87
.83
.85
.82
.83
.81
.79
4
.89
.86
.83
.82
.85
.81
.84
.80
.82
.79
.78
5
.87
.84
.81
.79
.83
.79
.82
.78
.81
.78
.76
6
.86
.82
.80
.78
.82
.78
.81
.77
.80
.77
.76
7
.84
.81
.78
.76
.80
.76
.79
.76
.79
.75
.75
8
.83
.79
.77
.75
.78
.75
.78
.75
.77
.74
.73
9
.82
.78
.76
.74
.77
.74
.77
.74
.77
.73
.73
10
.81
.77
.74
.72
.76
.72
.76
.72
.75
.72
.72
LUMINAIRE INPUT WATTS = 110.0
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
70W PAR38 WIDE FLOOD
MH PHILIPS 3K , LUMEN RATING = 4800 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH TRIM
1,000
2,000
3,000
4,000
30°
60°
ANGLE
MEAN CP
LUMENS
0
4053
5
3975
378
10
3826
15
3646
1020
20
3278
25
2623
1235
30
2144
35
1451
831
40
248
45
18
55
50
0
55
0
0
60
0
65
0
0
70
0
75
0
0
80
0
85
0
0
90
0
ZONAL LUMENS AND PERCENTAGES
ZONE
LUMENS % LAMP %LUMINAIRE
0-30
5505
80.97
98.84
0-30
2632
54.84
74.81
0-40
3463
72.16
98.43
0-60
3518
73.31
100
0-90
3518
73.31
100
40-90
55
1.15
1.57
60-90
0
0
0
90-180
0
0
0
0-180
3518
73.31
100
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE
MEAN CD/SQ M
45
901
55
0
65
0
75
0
85
0
** EFFICIENCY = 73.3% **
CERTIFIED TEST REPORT NO. 2454FR, DATE: FEB 12, 2004
SC = .9
COMPUTED BY LSI PROGRAM **TEST-LITE**
CEILING
80%
70%
50%
30%
WALL
70
50
30
10
50
10
50
10
50
10
0
RCR
0
.87
.87
.87
.87
.85
.85
.81
.81
.78
.78
.73
1
.84
.82
.81
.79
.81
.78
.78
.76
.75
.74
.70
2
.81
.78
.76
.74
.77
.73
.74
.71
.72
.70
.67
3
.78
.74
.71
.69
.73
.69
.71
.67
.70
.66
.64
4
.75
.71
.68
.65
.70
.65
.68
.64
.67
.63
.62
5
.72
.67
.64
.61
.66
.61
.65
.60
.64
.60
.58
6
.69
.64
.61
.58
.64
.58
.63
.58
.62
.57
.56
7
.66
.61
.57
.55
.61
.55
.60
.55
.59
.54
.53
8
.64
.58
.54
.52
.57
.52
.57
.52
.56
.51
.50
9
.61
.55
.52
.49
.55
.49
.54
.49
.54
.49
.48
10
.58
.52
.49
.46
.52
.46
.52
.46
.51
.46
.45
LUMINAIRE INPUT WATTS = 78.0
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
100W PAR38 WIDE FLOOD
MH PHILIPS 3K , LUMEN RATING = 6800 LMS, ELECTRONIC AROMAT BALLAST, - CL FINISH TRIM
1,875
3,750
5,625
7,500
30°
60°
ANGLE
MEAN CP
LUMENS
0
7353
5
6975
657
10
6231
15
5506
1553
20
4664
25
3597
1691
30
2759
35
1759
1031
40
288
45
39
74
50
14
55
3
5
60
1
65
0
0
70
0
75
0
0
80
0
85
0
0
90
0
ZONAL LUMENS AND PERCENTAGES
ZONE
LUMENS % LAMP %LUMINAIRE
0-30
3901
57.37
77.85
0-40
4932
72.53
98.43
0-60
5010
73.68
100
0-90
5010
73.69
100
40-90
78
1.16
1.57
60-90
0
0
0
90-180
0
0
0
0-180
5010
73.69
100
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE
MEAN CD/SQ M
45
1960
55
178
65
0
75
0
85
0
CEILING
80%
70%
50%
30%
WALL
70
50
30
10
50
10
50
10
50
10
0
RCR
0
.88
.88
.88
.88
.86
.86
.82
.82
.78
.78
.74
1
.85
.83
.81
.80
.82
.79
.78
.76
.76
.74
.71
2
.81
.79
.77
.74
.77
.74
.75
.72
.73
.71
.68
3
.79
.75
.72
.70
.74
.70
.72
.68
.71
.67
.65
4
.76
.72
.69
.66
.71
.66
.69
.65
.68
.64
.63
5
.73
.68
.65
.62
.68
.62
.66
.62
.65
.61
.60
6
.71
.66
.62
.60
.65
.59
.64
.59
.63
.59
.58
7
.68
.62
.59
.57
.62
.56
.61
.56
.60
.56
.55
8
.65
.60
.56
.54
.59
.54
.59
.54
.58
.53
.52
9
.63
.57
.53
.51
.57
.51
.56
.51
.55
.51
.50
10
.60
.54
.51
.49
.54
.49
.54
.48
.53
.48
.47
LUMINAIRE INPUT WATTS = 110.0
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%