background image

**  EFFICIENCY = 73.7%  **

CERTIFIED TEST REPORT NO. 2456FR, DATE: FEB 13,

SC = .8

2004  COMPUTED BY LSI PROGRAM **TEST-LITE**

Calculite

®

HID Downlight

C6P38MH

Page 1 of 2

6" Aperture, PAR38 Ceramic MH

Lightolier 

a Genlyte Thomas Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504

Job Information

Type:

70W PAR38 FLOOD 

MH PHILIPS 3K , LUMEN RATING = 4800 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH TRIM

5,000

10,000

15,000

20,000

30°

60°

ANGLE

MEAN CP

LUMENS

0

20134

5

17728

1622

10

12396

15

6288

1901

20

1851

25

460

337

30

140

35

64

47

40

29

45

10

9

50

0

55

0

0

60

0

65

0

0

70

0

75

0

0

80

0

85

0

0

90

0

ZONAL LUMENS AND PERCENTAGES

ZONE

LUMENS % LAMP %LUMINAIRE

0-30

3860

80.42

98.57

0-40

3906

81.39

99.76

0-60

3916

81.59

100

0-90

3916

81.59

100

40-90

9

0.19

0.24

60-90

0

0

0

90-180

0

0

0

0-180

3916

81.59

100

LUMINANCE SUMMARY - CD. / SQ. M.

ANGLE

MEAN CD/SQ M        

45

479

55

0

65

0

75

0

85

0

**  EFFICIENCY = 81.6%  **

CERTIFIED TEST REPORT NO. 2453FR, DATE: FEB 12, 2004

SC = .4

COMPUTED BY LSI PROGRAM **TEST-LITE**

CEILING

80%

70%

50%

30%

WALL

70

50

30

10

50

10

50

10

50

10

RCR

0

.97

.97

.97

.97

.95

.95

.91

.91

.87

.87

.82

1

.95

.93

.92

.91

.92

.89

.88

.87

.85

.84

.80

2

.92

.90

.88

.86

.89

.86

.86

.84

.84

.82

.79

3

.90

.88

.85

.84

.87

.83

.85

.82

.83

.81

.79

4

.89

.86

.83

.81

.85

.81

.83

.80

.82

.79

.78

5

.87

.84

.81

.79

.83

.79

.82

.78

.80

.78

.76

6

.86

.82

.80

.78

.82

.78

.81

.77

.80

.77

.76

7

.84

.80

.78

.76

.80

.76

.79

.76

.78

.75

.74

8

.83

.79

.77

.75

.78

.75

.78

.75

.77

.74

.73

9

.82

.78

.76

.74

.77

.74

.77

.73

.76

.73

.73

10

.80

.76

.74

.72

.76

.72

.76

.72

.75

.72

.71

LUMINAIRE INPUT WATTS = 78.0

Coefficients of Utilization

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

100W PAR38 FLOOD 

MH PHILIPS 3K , LUMEN RATING = 6800 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH TRIM

6,500

13,000

19,500

26,000

30°

60°

ANGLE

MEAN CP

LUMENS

0

26152

5

24195

2202

10

17741

15

9134

2760

20

2934

25

793

544

30

182

35

78

57

40

29

45

4

7

50

0

55

0

0

60

0

65

0

0

70

0

75

0

0

80

0

85

0

0

90

0

ZONAL LUMENS AND PERCENTAGES

ZONE

LUMENS % LAMP %LUMINAIRE

0-30

5505

80.97

98.84

0-40

5563

81.82

99.87

0-60

5570

81.92

100

0-90

5570

81.92

100

40-90

7

0.11

0.13

60-90

0

0

0

90-180

0

0

0

0-180

5570

81.92

100

LUMINANCE SUMMARY - CD. / SQ. M.

ANGLE

MEAN CD/SQ M        

45

221

55

0

65

0

75

0

85

0

**  EFFICIENCY = 81.9%  **

CERTIFIED TEST REPORT NO. 2455FR, DATE: FEB 13, 2004

SC = .4

COMPUTED BY LSI PROGRAM **TEST-LITE**

CEILING

80%

70%

50%

30%

WALL

70

50

30

10

50

10

50

10

50

10

RCR

0

.98

.98

.98

.98

.95

.95

.91

.91

.87

.87

.82

1

.95

.94

.92

.91

.92

.90

.89

.87

.86

.84

.81

2

.93

.90

.89

.87

.89

.86

.86

.84

.84

.82

.80

3

.91

.88

.86

.84

.87

.83

.85

.82

.83

.81

.79

4

.89

.86

.83

.82

.85

.81

.84

.80

.82

.79

.78

5

.87

.84

.81

.79

.83

.79

.82

.78

.81

.78

.76

6

.86

.82

.80

.78

.82

.78

.81

.77

.80

.77

.76

7

.84

.81

.78

.76

.80

.76

.79

.76

.79

.75

.75

8

.83

.79

.77

.75

.78

.75

.78

.75

.77

.74

.73

9

.82

.78

.76

.74

.77

.74

.77

.74

.77

.73

.73

10

.81

.77

.74

.72

.76

.72

.76

.72

.75

.72

.72

LUMINAIRE INPUT WATTS = 110.0

Coefficients of Utilization

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

70W PAR38 WIDE FLOOD 

MH PHILIPS 3K , LUMEN RATING = 4800 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH TRIM 

1,000

2,000

3,000

4,000

30°

60°

ANGLE

MEAN CP

LUMENS

0

4053

5

3975

378

10

3826

15

3646

1020

20

3278

25

2623

1235

30

2144

35

1451

831

40

248

45

18

55

50

0

55

0

0

60

0

65

0

0

70

0

75

0

0

80

0

85

0

0

90

0

ZONAL LUMENS AND PERCENTAGES

ZONE

LUMENS % LAMP %LUMINAIRE

0-30

5505

80.97

98.84

0-30

2632

54.84

74.81

0-40

3463

72.16

98.43

0-60

3518

73.31

100

0-90

3518

73.31

100

40-90

55

1.15

1.57

60-90

0

0

0

90-180

0

0

0

0-180

3518

73.31

100

LUMINANCE SUMMARY - CD. / SQ. M.

ANGLE

MEAN CD/SQ M        

45

901

55

0

65

0

75

0

85

0

**  EFFICIENCY = 73.3%  **

CERTIFIED TEST REPORT NO. 2454FR, DATE: FEB 12, 2004

SC = .9

COMPUTED BY LSI PROGRAM **TEST-LITE**

CEILING

80%

70%

50%

30%

WALL

70

50

30

10

50

10

50

10

50

10

RCR

0

.87

.87

.87

.87

.85

.85

.81

.81

.78

.78

.73

1

.84

.82

.81

.79

.81

.78

.78

.76

.75

.74

.70

2

.81

.78

.76

.74

.77

.73

.74

.71

.72

.70

.67

3

.78

.74

.71

.69

.73

.69

.71

.67

.70

.66

.64

4

.75

.71

.68

.65

.70

.65

.68

.64

.67

.63

.62

5

.72

.67

.64

.61

.66

.61

.65

.60

.64

.60

.58

6

.69

.64

.61

.58

.64

.58

.63

.58

.62

.57

.56

7

.66

.61

.57

.55

.61

.55

.60

.55

.59

.54

.53

8

.64

.58

.54

.52

.57

.52

.57

.52

.56

.51

.50

9

.61

.55

.52

.49

.55

.49

.54

.49

.54

.49

.48

10

.58

.52

.49

.46

.52

.46

.52

.46

.51

.46

.45

LUMINAIRE INPUT WATTS = 78.0

Coefficients of Utilization

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

100W PAR38 WIDE FLOOD 

MH PHILIPS 3K , LUMEN RATING = 6800 LMS, ELECTRONIC AROMAT BALLAST,  - CL FINISH TRIM 

1,875

3,750

5,625

7,500

30°

60°

ANGLE

MEAN CP

LUMENS

0

7353

5

6975

657

10

6231

15

5506

1553

20

4664

25

3597

1691

30

2759

35

1759

1031

40

288

45

39

74

50

14

55

3

5

60

1

65

0

0

70

0

75

0

0

80

0

85

0

0

90

0

ZONAL LUMENS AND PERCENTAGES

ZONE

LUMENS % LAMP %LUMINAIRE

0-30

3901

57.37

77.85

0-40

4932

72.53

98.43

0-60

5010

73.68

100

0-90

5010

73.69

100

40-90

78

1.16

1.57

60-90

0

0

0

90-180

0

0

0

0-180

5010

73.69

100

LUMINANCE SUMMARY - CD. / SQ. M.

ANGLE

MEAN CD/SQ M        

45

1960

55

178

65

0

75

0

85

0

CEILING

80%

70%

50%

30%

WALL

70

50

30

10

50

10

50

10

50

10

RCR

0

.88

.88

.88

.88

.86

.86

.82

.82

.78

.78

.74

1

.85

.83

.81

.80

.82

.79

.78

.76

.76

.74

.71

2

.81

.79

.77

.74

.77

.74

.75

.72

.73

.71

.68

3

.79

.75

.72

.70

.74

.70

.72

.68

.71

.67

.65

4

.76

.72

.69

.66

.71

.66

.69

.65

.68

.64

.63

5

.73

.68

.65

.62

.68

.62

.66

.62

.65

.61

.60

6

.71

.66

.62

.60

.65

.59

.64

.59

.63

.59

.58

7

.68

.62

.59

.57

.62

.56

.61

.56

.60

.56

.55

8

.65

.60

.56

.54

.59

.54

.59

.54

.58

.53

.52

9

.63

.57

.53

.51

.57

.51

.56

.51

.55

.51

.50

10

.60

.54

.51

.49

.54

.49

.54

.48

.53

.48

.47

LUMINAIRE INPUT WATTS = 110.0

Coefficients of Utilization

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

Отзывы: