background image

Lighting Systems

 

Baselyte-BSL29

Page 2 of 4   

 Light T8 Wall Mount Indirect

Lightolier 

a Genlyte Company 

www.lightolier.com

63 Airport Road, Fall River, MA 02720 • (508) 679-83 • Fax (508) 674-470

We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.

Job Information 

Type:

Performance

Candlepower Curve

Candlepower Summary

Coefficients of Utilization

Report No:

 20687

Lamps: 

F32T8

Lumens per Lamp: 

2950

Efficiency: 

50.0%

Up:

 00.0%  

Down:

 0.0%

Zonal Lumen Summary

ZONE        LUMENS        %BARE LAMP       %LUMINAIRE

CANDLEPOWER SUMMARY

ZONE

CANDLEPOWER

DEG.

0

45

90

135

180

180

309

309

309

309

309

175

327

322

308

293

288

165

354

340

299

257

242

155

414

349

279

216

196

145

510

389

250

174

155

135

606

440

215

134

115

125

714

492

173

98

93

115

764

532

126

71

74

105

480

466

70

49

48

95

168

166

18

17

19

90

14

15

1

5

6

85

0

0

0

0

0

75

0

0

0

0

0

65

0

0

0

0

0

55

0

0

0

0

0

45

0

0

0

0

0

35

0

0

0

0

0

25

0

0

0

0

0

15

0

0

0

0

0

5

0

0

0

0

0

0

0

0

0

0

0

COEFFICIENTS OF UTILIZATION

% EFFECTIVE CEILING CAVITY REFLECTANCE

80

70

50

% WALL REFLECTANCE

50

30

10

50

30

10

50

30

10

0

47

47

47

40

40

40

27

27

27

1

41

39

38

35

34

32

24

23

22

2

36

33

31

31

28

26

21

19

18

3

31

28

25

27

24

22

18

17

15

4

27

24

21

24

21

18

16

14

13

5

24

21

18

21

18

15

14

12

11

6

22

18

15

18

15

13

13

11

9

7

19

16

13

16

13

11

11

9

8

8

17

14

11

15

12

10

10

8

7

9

16

12

10

13

10

8

9

7

6

10 14

11

9

12

9

7

8

6

5

ZONAL LUMEN SUMMARY

ZONE LUMENS % BARE LAMP

%LUMINAIRE

0-90
90-180
0-180

1475

1475

0

0
100.0
100.0

0
50.0
50.0

COEFFICIENTS OF UTILIZATION

% EFFECTIVE CEILING CAVITY REFLECTANCE

80

70

50

% WALL REFLECTANCE

50

30

10

50

30

10

50

30

10

0

47

47

47

40

40

40

27

27

27

1

41

39

38

35

34

32

24

23

22

2

36

33

31

31

28

26

21

19

18

3

31

28

25

27

24

22

18

17

15

4

27

24

21

24

21

18

16

14

13

5

24

21

18

21

18

15

14

12

11

6

22

18

15

18

15

13

13

11

9

7

19

16

13

16

13

11

11

9

8

8

17

14

11

15

12

10

10

8

7

9

16

12

10

13

10

8

9

7

6

10 14

11

9

12

9

7

8

6

5

ZONAL LUMEN SUMMARY

ZONE LUMENS % BARE LAMP

%LUMINAIRE

0-90
90-180
0-180

1475

1475

0

0
100.0
100.0

0
50.0
50.0

Module Lengths & Mounting Distances

Run Configuration 

Run

Length

 

4’ 

Module

8’

Module

2’ 

Module

Joiner

End Set

Mount

Power 

Mount* 

4’ run

8’ run

2’ run

6’ run

2

2

20’ run

2

24’ run

2

2

28’ run

2

2

3

32’ run

2

3

-ODULE,ENGTH

-OUNTING$ISTANCE

-ODULE,ENGTH-OUNTING$ISTANCE

-ODULE,ENGTH-OUNTING$ISTANCE

@

@

@

Joiner

BSLEWW

 = wall mount standard white

Dust Cover

End Set

BSLJW

 = wall mount joiner 

BSLDCW

 = 4’ wall mount dust cover 

System Components & Accessories

Non-Power Wall Mount

Power Wall Mount

BSLWP1 

= -power mount

BSLWP2 

= 2-power mount

BSLWN

 = non-power wall mount

Note

: Shaded area indicates locations of emergency sections (emergency wiring  

controls all lamps or optional battery pack controls one or two lamps).

*Note

: Additional power mounts may be required for some runs with T5 HO 

lamping options, longer runs, and runs with wiring options that are more complex. 
Please consult factory for assistance.

Содержание Baselyte-BSL29

Страница 1: ... Ballasts electronic 120V or 277V Finish High quality white powder coat with textured matte finish Custom colors available Consult factory Mounting Flexible mounting locations Electrical All luminaires are factory pre wired to module ends with quick wire connectors Joints Intersections Self aligning joining system with hands free pre joining wire access Labels UL CSA standards Individual Fixtures ...

Страница 2: ... 7 8 6 5 ZONAL LUMEN SUMMARY ZONE LUMENS BARE LAMP LUMINAIRE 0 90 90 180 0 180 1475 1475 0 0 100 0 100 0 0 50 0 50 0 COEFFICIENTS OF UTILIZATION EFFECTIVE CEILING CAVITY REFLECTANCE 80 70 50 WALL REFLECTANCE 50 30 10 50 30 10 50 30 10 0 47 47 47 40 40 40 27 27 27 1 41 39 38 35 34 32 24 23 22 2 36 33 31 31 28 26 21 19 18 3 31 28 25 27 24 22 18 17 15 4 27 24 21 24 21 18 16 14 13 5 24 21 18 21 18 15 ...

Страница 3: ...gh performance C1400 Type P Bodine high performance B50 All lamps wired on one circuit plus a battery pack is wired to one lamp A hot lead is connected to the battery pack and would function as a trigger wire when connected to a constant hot by installer Leads for both normal circuit and battery pack are wired to fixture ends 1 Circuit with Emergency Battery Pack EM One 4 section in a one circuit ...

Страница 4: ...ons with Emergency Battery Pack EM Fixture wired for two circuit Lamps wired for A B switching in alternate 4 sections 2 Circuit A B Switching alternate 4 sections Type B 2cct Type A 2cct w 1cct thru wire Type S 2cct w 2cct thru wire 2 Circuit A B Switching alternate 4 sections with Emergency Circuit Night Light EC NL One 4 section in a two circuit fixture A B switching to be wired on a separate t...

Отзывы: