34
Guying
There are two methods of coupling two sections of mast:
1. The U-Bolt set uses two stainless steel U-Bolts to clamp the two
masts together.
2. The inline coupling fixes the upper and lower mast sections
together and provides guying points and an exit point for the HVSC
downconductor.
Mast
Couplings and
Guying Points
Figure 31.
U-Bolts and Inline Couplings nuts must be tightened to no more than
55kg/cm (45in.lb).
A Guying Ring is supplied for guy points for any two piece masts that
require double guying. This fits on the terminals mast butt adaptor
between the Stormaster ESE terminal and the top of the mast. See Figure
32 under the heading titled Guying.
LPI offers a standard 4m (13 ft) guy kit made up of light weight plastic
coated fibreglass non-conductive cable. If using conductive guy lines
they must be connected at the lower anchor points to the downconductor
by a conductor, or alternatively use appropriate guying insulators.