Lighthouse ActiveCount100 Operating Manual 

 

248083444-1 Rev 2                                     

 

 

 

P a g e  

40  of  40 

Appendix C:  Limited Warranty 

Limitation of Warranties

 

A.

 

Lighthouse Worldwide Solutions (LWS) warrants that all equipment shall be free from defects in material and workmanship under 

normal use for a period of two years from date of shipment to Buyer.  LWS does not warrant that operation of the software will be 

completely uninterrupted or error free or that all program errors will be corrected. Buyer shall be responsible for determining 

that the equipment is suitable for Buyer’s use and that such use complies with any applicable local, state, or federal law. 

Provided 

that Buyer notifies LWS in writing of any claimed defect in the equipment immediately upon discovery and any such equipment is 

returned to the original shipping point, transportation charges prepaid, within two years from date of shipment to Buyer and upon 

examination LWS determines to its satisfaction that such equipment is defective in material or workmanship, i.e. contains a defect 

arising out of the manufacture of the equipment and not a defect caused by other circumstances, including, but not limited to 

accident, misuse, unforeseeable use, neglect, alteration, improper installation, improper adjustment, improper repair, or improper 

testing, LWS shall, at its option, repair or replace the equipment, shipment to Buyer prepaid. LWS shall have reasonable time to 
make such repairs or to replace such equipment. Any repair or replacement of equipment shall not extend the period of warranty. 

If the Instrument is modified or in any way altered without the explicit written consent of LWS then the warranty is null and void. 

This warranty is limited to a period of two years, except as noted below, without regard to whether any claimed defects were 

discoverable or latent on the date of shipment. The length of warranty for pumps in hand held particle counters is one (1) year. 

Batteries and accessories with all products are warranted for one (1) year. Fuses and purge filters carry no warranty. If a third 

party battery is used in the product, the product warranty is null and void. If the battery is charged by a third party battery charger 
the battery warranty is null and void. 

 

B.

 

If Buyer shall fail to pay when due any portion of the purchase price or any other payment required from Buyer to LWS under this 

contract or otherwise, all warranties and remedies granted under this Section may, at LWS’s option, be terminated.

 

 

C.

 

THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER REPRESENTATIONS, WARRANTIES AND COVENANTS, 
EXPRESS OR IMPLIED WITHRESPECT TO THE EQUIPMENT AND ANY DEFECTS THEREIN OF ANY NATURE WHATEVER, 

INCLUDING AND WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. LWS 

SHALL NOT BE LIABLE FOR, AND BUYER ASSUMES ALL RISK OF, ANY ADVICE OR FAILURE TO PROVIDE ADVICE BY LWS TO 

BUYER  

REGARDING THE EQUIPMENT OR BUYERS USE  
OF THE SAME. UNDER NO CIRCUMSTANCES SHALL LWS BE LIABLE TO BUYER UNDER ANY TORT, NEGLIGENCE, STRICT 
LIABILITY, OR PRODUCT LIABILITY CLAIM AND BUYER AGREES TO WAIVE SUCH CLAIMS. 

LWS’s SOLE AND EXCLUSIVE 

LIABILITY AND BUYERS SOLE AND EXCLUSIVE REMEDY, FOR ANY NONCONFORMITY OR DEFECT IN THE PRODUCTS OR 
ANYTHING DONE IN CONNECTION WITH THIS CONTRACT, IN TORT, (INCLUDING NEGLIGENCE), CONTRACT, OR OTHERWISE, 
SHALL BE AS SET FORTH IN THE SUBSECTION A HEREOF AS LIMITED BY SUBSECTION B HEREOF. THIS EXCLUSIVE REMEDY 
SHALL NOT HAVE FAILED OF ITS ESSENTIAL PURPOSE (AS THAT TERM IS USED IN THE UNIFORM COMMERCIAL CODE) 
PROVIDED THAT THE SELLER REMAINS WILLING TO REPAIR OR REPLACE DEFECTIVE EQUIPMENT (AS DEFINED IN 
SUBSECTION A) WITH A COMMERCIALLY REASONABLE TIME AFTER RECEIVING SUCH EQUIPMENT. BUYER SPECIFICALLY 

ACKNOWLEDGES THAT SELLER’S PRICE FOR T

HE EQUIPMENT IS BASED 

UPON THE LIMITATIONS OF LWS’S LIABILITY AS 

SET 

FORTH IN THIS CONTRACT. 
 

 

Warranty of Repairs After Initial Two (2) Year Warranty

 

A.

 

Upon expiration of the initial two-year warranty, all parts and repairs completed by an authorized Lighthouse repair technician 

are subject to a six (6) month warranty. 

 

B.

 

Other than the above, LWS makes no warranty of any kind expressed or implied, except that the products manufactured and sold 

by LWS shall be free from defects in materials and workmanship and 

shall conform to LWS’s specifications; Buyer assumes all risk 

and liability resulting from use of the products whether used singly or in combination with other products. If instrument is 

modified or in any way altered without the explicit written consent of LWS, then the warranty is null and void. 

 

C.

 

WARRANTY REPAIRS SHALL BE COMPLETED AT THE FACTORY, BY AN AUTHORIZED SERVICE LOCATION, BY AN AUTHORIZED 

SERVICE TECHNICIAN, OR ON SITE AT BUYER’S FACILITY BY A LIGHTHOUSE AUTHORIZED EMPLOYEE. BUYER PAYS FREIGHT 

TO FACTORY; SELLER WILL PAY STANDARD RETURN FREIGHT DURING THE WARRANTY PERIOD. BUYER MAY SELECT A 

FASTER METHOD OF SHIPMENT AT ITS OWN EXPENSE.

 

Содержание ActiveCount100

Страница 1: ...ActiveCount100 M I C R O B I O L O G I C A L S A M P L E R Operators Manual 00 10 00 79 02 26 2015 LOC001 12 45 30 PM 0 0 L 00 10 00 USER001 1000L...

Страница 2: ...Blank Page...

Страница 3: ...ion except as permitted in writing by Lighthouse Worldwide Solutions The information contained herein is subject to change without notice Lighthouse Worldwide Solutions is not responsible for any dama...

Страница 4: ...lume 20 Select Total Sampling Volume 20 Active Volume Applies to Sampling Runs 20 Locations and Users 21 Assigns Active Location to Sampling Runs 21 Assigns Active User to Sampling Runs 22 Data Loggin...

Страница 5: ...es in Comma Delimited Files 36 Location Database 36 User Database 36 Sampling Run Databases 37 Appendix B Feller Conversion Table 39 Sampling Head with 300 Holes x 0 6mm 39 Appendix C Limited Warranty...

Страница 6: ...010 1 2010 CAN CSA C22 2 No 1010 1 1992 Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use Part 1 General Requirements EMC EN61326 1 2006 Electrical Equipment for...

Страница 7: ...wn method impaction to aspirate air through a perforated plate and deposit airborne bacteria onto an agar coated petri dish The petri dish is then removed incubated and tested for live microorganisms...

Страница 8: ...finger on the touch screen Power on ActiveCount100H and continue to hold your finger on the touch screen until the Performing touch screen calibration screen appears 3 Follow the prompts to calibrate...

Страница 9: ...ling head dust cover Autoclavable sampling head and dust cover Aluminum sampling head Stainless steel sampling head optional Uses standard ISO 24998 90mm petri dishes Status LED Allen wrench to adjust...

Страница 10: ...of 40 Plug In USB Flash Drive and Charge Battery Data logging Insert the included USB flash drive to store sampling run metadata Charge battery Follow the instructions below to charge the ActiveCount...

Страница 11: ...Operating Manual 248083444 1 Rev 2 P a g e 11 of 40 Get Ready For Sampling Follow these steps to prepare Activecount100 for microorganism sampling When ActiveCount100 is not in use always cover sampl...

Страница 12: ...ble number is a well established method to estimate the number of viable microorganisms in a monitored area To derive MPN ActiveCount100 uses the principle that statistically assumes an increasing num...

Страница 13: ...me of air Periodic samples periodically for a user specified time and volume Sampling Mode Description Constant ActiveCount100 continuously samples until it reaches the desired sample volume at 100 li...

Страница 14: ...minute Periodic mode is useful when monitoring a process over longer periods e g manufacturing a batch or lot of food cosmetics or drugs In the example below select ten cycles over two hours and 1 000...

Страница 15: ...URATION button Select Constant in Mode menu item then select total sampling volume If desired also select an optional delay time in seconds Press HOME button to return to the Home screen Begin samplin...

Страница 16: ...ATION button Select Periodic in Mode menu item then select total sampling volume delay time total time to sample and the number of cycles Press HOME button to return to the Home screen Begin sampling...

Страница 17: ...ecurity Configuration Lock ActiveCount100 Sampling Modes can be restricted by locking the Configuration Screen Before locking the configuration screen select the sample mode and sample settings to be...

Страница 18: ...describes ActiveCount100 LED status Status Color Blink Idle Off Off Sampling Blue Solid Delay Pause Green Solid Flow Error Red Blinking Writing to USB White Solid Service Calibration Required Yellow S...

Страница 19: ...manual abort by user or c flow error a Success b Manual abort by user c Flow error Sampling Run Metadata Display Sampling Results To display metadata results for the most recent sampling run press ME...

Страница 20: ...n the Volume menu item ActiveCount100 displays eight sampling volumes ActiveCount100 indicates the active sampling volume with a dashed line Active Volume Applies to Sampling Runs ActiveCount100 uses...

Страница 21: ...igns Active Location to Sampling Runs Locations Database ActiveCount100 stores up to 400 locations in its Locations database When ActiveCount100 completes a sampling run it saves the active location i...

Страница 22: ...2 of 40 Assigns Active User to Sampling Runs Users Database ActiveCount100 stores up to 50 users When ActiveCount100 completes a sampling run it saves the active user in a metadata record for the most...

Страница 23: ...ying metadata for the most recent sampling run see Section Display Sampling Metadata USB Flash Drive When a USB flash drive is plugged into the rear USB port ActiveCount100 displays a USB flash drive...

Страница 24: ...ndicators Status Indicators ActiveCount100 displays status indicators on the Home screen If ActiveCount100 displays Device status flag it may indicate a device issue or problem To display more device...

Страница 25: ...ntact information Device status flag Possible device error e g flow error calibration due etc To display the device status press SETTINGS button and Status menu item The sampling database stores these...

Страница 26: ...Lighthouse ActiveCount100 Operating Manual 248083444 1 Rev 2 P a g e 26 of 40 Settings ActiveCount100 Settings Device Settings Press SETTINGS button to display and edit device settings...

Страница 27: ...zontal Sampling Vertical Sampling Place ActiveCount100 on a horizontal surface to sample vertically Horizontal Sampling Mount ActiveCount100 on a tripod monopod and turn the instrument to sample horiz...

Страница 28: ...of 40 Optional Compressed Gas Sampler Verify Nominal Flow Before Gas Sampling Before using the optional compressed gas sampler first verify nominal flow of ActiveCount100 without the gas sampler Add e...

Страница 29: ...l 248083444 1 Rev 2 P a g e 29 of 40 To verify ActiveCount100 nominal flow rate follow the steps below When ActiveCount100 displays the following screen position gas sampler snugly in the sampling hea...

Страница 30: ...oints straight up for nominal flow ActiveCount100 and the Gas Sampler adapter are now ready to sample compressed gas Press the BACK button to configure your gas sample Do not sample explosive nor corr...

Страница 31: ...issue Wipe dry with another sterile tissue Always full remove and wipe dry the disinfectant solution before reusing ActiveCount100 Let dry at room temperature Sampling Head Dust Cover Remove sampling...

Страница 32: ...ock turn off and disconnect power adapter during sterilization Do not submerge ActiveCount100 in any liquids Do not spray disinfectant solution directly into ActiveCount100 enclosure Do not use gases...

Страница 33: ...v 2 P a g e 33 of 40 Calibration Calibration Contact Authorized Facility ActiveCount100 is factory calibrated to 100 liters min 4 Contact a factory authorized facility to calibrate ActiveCount100 annu...

Страница 34: ...ogrammable cycles delay sample duration and volume Body made from stainless steel Sampling head made from anodized aluminum Optional sampling head made from polished stainless steel Autoclavable sampl...

Страница 35: ...inless steel sampling head Optional gas sampler Conforming Specifications CE 21 CFR Part 11 ISO 14698 1 Biocontamination Control Cleanrooms Associated Control Environments ISO 14698 2 Biocontamination...

Страница 36: ...0 0 None Good Good None 08 05 2015 15 02 56 LOC014 6 0 10 0 0 0 0 None Good Good None 08 05 2015 15 04 57 LOC015 6 0 10 0 0 0 0 None Good Good None 08 05 2015 15 05 19 LOC016 6 0 10 0 0 0 0 None Good...

Страница 37: ...ted fields for each sampling run CSV Field Description Sample Value 1 Timestamp Date format set in Settings menu US MM DD YYYY EU DD MM YYYY ISO YYYY MM DD Time local 24 hour time HH MM 7 16 2015 9 48...

Страница 38: ...USB flash drive not detected Error Error 16 Model Name ActiveCount100 model name ActiveCount100 17 Serial Number ActiveCount100 serial number 0123456789 18 Flow Rate ActiveCount100 flow rate 100 L m 1...

Страница 39: ...220 395 270 686 21 22 71 81 121 155 171 253 221 399 271 696 22 23 72 82 122 156 172 255 222 403 272 707 23 24 73 83 123 158 173 257 223 407 273 717 24 25 74 85 124 160 174 260 224 410 274 728 25 26 75...

Страница 40: ...act or otherwise all warranties and remedies granted under this Section may at LWS s option be terminated C THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER REPRESENTATIONS WARRANTIES AND...

Страница 41: ...Service and Support Tel 1 800 945 5905 USA Toll Free Tel 1 541 770 5905 Outside of USA techsupport golighthouse com www golighthouse com...

Отзывы:

Похожие инструкции для ActiveCount100