background image

3

The products referred to in this manual conform to the European Community Directives to which

they are subject:

Low Voltage 2014/35/EU

Electromagnetic Compatibility 2014/30/EU

Never look directly into the light source. You risk injury to your retina, which may induce blindness.

Do not stare directly into the light output.Never look at an exposed lamp while it is lit.

 Protection optical radiation

 Protection against explosion

The protection screen, lens or ultraviolet screen on the lamp can be damaged to the degree 

of failure if visible damage, such as a crack or deep mark, should be replaced

The tting mounts a high-pressure lamp that needs an external .

Immediately replace the lamp if damaged or deformed by heat.

The light source in this xture shall be replaced by the manufacturer or its service agent or 

similar qualication.

Always disconnect from mains before replacing the lamp.

 Temperature of the external surface

The maximum temperature that can be reached on the external surface of the fitting, in a thermally

steady state, is 

100

.

 Maintenance

 

Before starting any maintenance work or cleaning the projector, cut off power from the mains supply.

After switching off, do not remove any parts of the fitting, to avoid getting burnt for at least 30 minutes. 

After this time the likelihood of the lamp exploding is virtually nill.

The fitting is designed to hold in any splinters produced by a lamp exploding. 

The lenses must be mounted and, if visibly Damaged, they have to be replaced with genuine spares.

Lamp 

The product implementation standard

GB

 

7000

.

1

-

2015

   

GB7000

.

217

-

2008

When the luminaire projects an object, the minimum distance of the luminaire to 
the ammable object is 12 meters

.

Содержание AQUABEAM400 LL

Страница 1: ...AQUABEAM400 LL Please read these user manual carefully before use E mail n Address No 43 Yunfeng Road Xiuquan Street Huadu District Guangzhou China...

Страница 2: ...y to ensure excellent performance and best meet your expectations and requirements Carefully read this user manual in its entirety and keep it safe for future reference It is essential to know the inf...

Страница 3: ...n Keep all combustible materials at least 1 m away from the fixture The fixture is intended for indoor and outdoor application Do not operate the fixture if the ambient temperature Ta exceeds 40 Prote...

Страница 4: ...ure shall be replaced by the manufacturer or its service agent or similar quali cation Always disconnect from mains before replacing the lamp Temperature of the external surface The maximum temperatur...

Страница 5: ...stroboscopic Control Mode DMX512 X Y Travel 540 270 X Y Resolution 2 11 1 05 X Y Speed 2 9S 1 2S Channel 17CH Standard Softwareupgrade UpgradeviaDMXinterface Display Menu Thedisplaypaneladoptsa2 0 in...

Страница 6: ...5 Static gobo wheel 1 2 3 4 5 6 7 8 9 10 11 12 13 14 C M Y 1 1 1 1 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 CMY color mixing system Color wheel Prism wheel 1 Prism wheel 2 2 3...

Страница 7: ...0 15335 70000 6506 40000 3717 24900 2314 17140 1592 0 2 10 0 35 0 69 1 04 1 4 1 8 2 08 2 8 1 2 2 3 3 5 4 7 5 11 6 10 9 2 6 Distance m ft in Diameter m ft in 2 6600 613 distance spot diameter and illum...

Страница 8: ...power cord ATTACHMENT AND BODY SIZE 7 2 573 374 635 410 300 410...

Страница 9: ...fitted This must be securely fixed to the support structure of the projector and then connected to the base handle Make sure all parts for fixing the projector are in a good state of repair Make sure...

Страница 10: ...g is working normally Connection to the eiectricty mains must be carried out by a qualified electrical installer The stage lighting power supply can not be more than 2pcs pre line The N terminal is co...

Страница 11: ...onnected Not connected 3 1 2 3 DMX input Shield Signal Signal Not connected Not connected 4 5 4 5 DMX512 in out in out in signal end The projector all the projectors are together dn t touch each other...

Страница 12: ...nter OK function Exit in the choice screen DMX 001 DMX Address Information Personal Manual control Service Language Reversal UP DOWN LEFT RIGHT ENTER Press the switch The projector starts resetting th...

Страница 13: ...rature E ballast 000 0 Logged temperature E ballast Cur TEMP Max TEMP Min TEMP Return ESC Fan information Lamp fan 1 Power V 2 Speed 3 Speed R Big fan 1 Power V 2 SP Fan1 3 SP Fan1 R Buttom fan 1 SP F...

Страница 14: ...P T invert Pan invert OFF ON Tilt invert OFF ON Return ESC Display Backlight Always on Auto off 15s Rotate Normal Rotate 180 Backlight blink ON OFF Return ESC Return ESC Manual control Channel control...

Страница 15: ...000 255 Tilt 000 255 Dimmer1 000 255 Dimmer2 000 255 Cyan 000 255 Magenta 000 255 Yellow 000 255 Color 000 255 Static gobo 000 255 Focus 000 255 Frost 000 255 Prism 1 000 255 Prism 2 000 255 Return ES...

Страница 16: ...Test Pan Manual fan Vol FanSpeedToLamp Manual OR DMX Lamp Power Set Power Power ON OFF Load font Set LOGO UP LOGO Language 5Min Lamp off Return ESC Firmware update Return ESC Return ESC Lamp Off On L...

Страница 17: ...0 4 21 6 Lavender 56 59 22 0 23 1 Lavender Pink 60 63 23 5 24 7 Pink 64 68 25 1 26 7 Pink Yellow 69 72 27 0 28 2 Yellow 73 76 28 6 29 8 Yellow Magenta 77 81 30 2 31 8 Magenta 82 85 32 2 33 3 Magenta C...

Страница 18: ...Slow Fast Speed 74 87 29 0 34 1 Gobo2 Shake Slow Fast Speed 88 101 31 4 39 6 Gobo3 Shake Slow Fast Speed 102 115 40 0 45 1 Gobo4 Shake Slow Fast Speed 116 129 45 5 50 6 Gobo5 Shake Slow Fast Speed 130...

Страница 19: ...5 0 5 9 Unused Range 16 55 6 3 21 6 Fast Slow 8 prism free switch 56 95 22 0 37 3 Fast Slow 16prism free switch 96 135 37 6 52 Fast Slow 8 prism 16prism Simultaneous free switch 136 175 53 3 68 Fast S...

Страница 20: ...5 Display board GND N Fan controlling board FAN 3QD V1 02 Fan Fan Fan Fan Fan Fan Fan Fan CMY Drive board SL 6M V1 0 SL001 CG V1 1 NC SL CG1 V1 01 SL CG1 V1 01 Yellow Magenta Cyan Dimmer1 Frost Dimmer...

Страница 21: ...20...

Страница 22: ...21...

Отзывы: