background image

2

 Connection to mains supply

 

The double insulation between the LV power supply and the control conductor on the fixture.

SAFETY

 

INFORMATION

This lighting fixture is for professional use only - it is not for household use.

 Installtion 

Make sure all parts for fixing the projector are in a good state of repair.

Make sure the point of anchorage is stable before positioning the projector.

The safety chain must be prgperly hooked onto the fitting and secured to the framework.

When suspending the fixture, ensure that the supporting structure and all hardware used

can hold at least 10 times the weight of all the devices they support.

Ensure

 

a

 

minimum

 

clearance

 

of

 

0

.

5m

 

around

 

the

 

cooling

 

fans

 

and

 

ventilation

.

Please do not install the fixture onto combustible surface.

Do not expose the front glass to sunlight or other strong light source from any angle.

Lenses can focus the sun's rays inside the fixture, creating a potential fire hazard.

 Mounting surface and fire protection 

Keep all combustible materials at least 1 m away from the fixture.

The

 

fixture

 

is

 

intended

 

for

 

indoor

 

and outdoor application

.

Do not operate the fixture if the ambient temperature (Ta) exceeds 40

Protection against electrical shock

Connection must be made to a power supply system fitted with efficient earthing (Class I

 appliance according to standard EN 60598-1).

It is,moreover, recommended to protect the supply lines of the projectors from indirect 

contact and/or shorting to earth by using appropriately sized residual current devices.

Connection to the electricity mains must be carried out by a qualified electrical installer.

Check that the mains frequency and voltage correspond to those for which the projector is designed

as given on the electrical data label.

This label also gives the input power to which you need to refer to evaluate the maximum number 

of fittings to connect to the electricity line, in order to avoid overloading.

Don’t use the power cable when the insulation is damaged.

It must be the manufacturer or distributor or the professional person to change the damaged power

cable in order to avoid any dangerous.

t

a

40

 Maximum ambient temperature

Содержание AQUABEAM400 LL

Страница 1: ...AQUABEAM400 LL Please read these user manual carefully before use E mail n Address No 43 Yunfeng Road Xiuquan Street Huadu District Guangzhou China...

Страница 2: ...y to ensure excellent performance and best meet your expectations and requirements Carefully read this user manual in its entirety and keep it safe for future reference It is essential to know the inf...

Страница 3: ...n Keep all combustible materials at least 1 m away from the fixture The fixture is intended for indoor and outdoor application Do not operate the fixture if the ambient temperature Ta exceeds 40 Prote...

Страница 4: ...ure shall be replaced by the manufacturer or its service agent or similar quali cation Always disconnect from mains before replacing the lamp Temperature of the external surface The maximum temperatur...

Страница 5: ...stroboscopic Control Mode DMX512 X Y Travel 540 270 X Y Resolution 2 11 1 05 X Y Speed 2 9S 1 2S Channel 17CH Standard Softwareupgrade UpgradeviaDMXinterface Display Menu Thedisplaypaneladoptsa2 0 in...

Страница 6: ...5 Static gobo wheel 1 2 3 4 5 6 7 8 9 10 11 12 13 14 C M Y 1 1 1 1 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 CMY color mixing system Color wheel Prism wheel 1 Prism wheel 2 2 3...

Страница 7: ...0 15335 70000 6506 40000 3717 24900 2314 17140 1592 0 2 10 0 35 0 69 1 04 1 4 1 8 2 08 2 8 1 2 2 3 3 5 4 7 5 11 6 10 9 2 6 Distance m ft in Diameter m ft in 2 6600 613 distance spot diameter and illum...

Страница 8: ...power cord ATTACHMENT AND BODY SIZE 7 2 573 374 635 410 300 410...

Страница 9: ...fitted This must be securely fixed to the support structure of the projector and then connected to the base handle Make sure all parts for fixing the projector are in a good state of repair Make sure...

Страница 10: ...g is working normally Connection to the eiectricty mains must be carried out by a qualified electrical installer The stage lighting power supply can not be more than 2pcs pre line The N terminal is co...

Страница 11: ...onnected Not connected 3 1 2 3 DMX input Shield Signal Signal Not connected Not connected 4 5 4 5 DMX512 in out in out in signal end The projector all the projectors are together dn t touch each other...

Страница 12: ...nter OK function Exit in the choice screen DMX 001 DMX Address Information Personal Manual control Service Language Reversal UP DOWN LEFT RIGHT ENTER Press the switch The projector starts resetting th...

Страница 13: ...rature E ballast 000 0 Logged temperature E ballast Cur TEMP Max TEMP Min TEMP Return ESC Fan information Lamp fan 1 Power V 2 Speed 3 Speed R Big fan 1 Power V 2 SP Fan1 3 SP Fan1 R Buttom fan 1 SP F...

Страница 14: ...P T invert Pan invert OFF ON Tilt invert OFF ON Return ESC Display Backlight Always on Auto off 15s Rotate Normal Rotate 180 Backlight blink ON OFF Return ESC Return ESC Manual control Channel control...

Страница 15: ...000 255 Tilt 000 255 Dimmer1 000 255 Dimmer2 000 255 Cyan 000 255 Magenta 000 255 Yellow 000 255 Color 000 255 Static gobo 000 255 Focus 000 255 Frost 000 255 Prism 1 000 255 Prism 2 000 255 Return ES...

Страница 16: ...Test Pan Manual fan Vol FanSpeedToLamp Manual OR DMX Lamp Power Set Power Power ON OFF Load font Set LOGO UP LOGO Language 5Min Lamp off Return ESC Firmware update Return ESC Return ESC Lamp Off On L...

Страница 17: ...0 4 21 6 Lavender 56 59 22 0 23 1 Lavender Pink 60 63 23 5 24 7 Pink 64 68 25 1 26 7 Pink Yellow 69 72 27 0 28 2 Yellow 73 76 28 6 29 8 Yellow Magenta 77 81 30 2 31 8 Magenta 82 85 32 2 33 3 Magenta C...

Страница 18: ...Slow Fast Speed 74 87 29 0 34 1 Gobo2 Shake Slow Fast Speed 88 101 31 4 39 6 Gobo3 Shake Slow Fast Speed 102 115 40 0 45 1 Gobo4 Shake Slow Fast Speed 116 129 45 5 50 6 Gobo5 Shake Slow Fast Speed 130...

Страница 19: ...5 0 5 9 Unused Range 16 55 6 3 21 6 Fast Slow 8 prism free switch 56 95 22 0 37 3 Fast Slow 16prism free switch 96 135 37 6 52 Fast Slow 8 prism 16prism Simultaneous free switch 136 175 53 3 68 Fast S...

Страница 20: ...5 Display board GND N Fan controlling board FAN 3QD V1 02 Fan Fan Fan Fan Fan Fan Fan Fan CMY Drive board SL 6M V1 0 SL001 CG V1 1 NC SL CG1 V1 01 SL CG1 V1 01 Yellow Magenta Cyan Dimmer1 Frost Dimmer...

Страница 21: ...20...

Страница 22: ...21...

Отзывы: