Light-ink SMOKE-1500 Скачать руководство пользователя страница 4

(2)

• Fog machine is for adult use. Keep out of reach of children. 
  Never leave the unit running unattended.
• Fog machine nozzle gets hot over 200 degrees (celsius) during  
  use. Don’t touch! Maintain a safe distance over 100CM. Never aim  
  the nozzle directly at people.
• Keep case closed while operating. Put fog machine in drafty place,  
  do not insert objects into air vents. Allow 20cm space or above  
  around the machine for proper ventilation.
• Keep fog machine away from flames and flammable items. 
  Never aim the nozzle at open flames or sparks. Use only high quality  
  water-based fog fluid. Never put flammable substances into the tank.
• Machine must cool down before cleaning, servicing or storing.
• Never put any flammable material (lipid, gas, perfume etc.) into the  
  tank, read the user manual thoroughly before operation.
• Better use our high quality water-based fog fluid, random use with  
  other fog fluid may jam the pipe, or even erode the components  

 inside.

• Keep sufficient fog fluid in tank. Operating the unit without    
  sufficient fog fluid, will damage the pump. 
• If any abnormal running occurs, stop it immediately, empty the fluid,  

  and bring the done up unit (recommend original box) to your agent  

  or dealer for servicing.  Make sure all fluid is empty from the tank  
  before moving or shipping.
• Never drink fog fluid. If fluid contacts eyes or skin, rinse skin   
  thoroughly with water.
• Read user manual instructions thoroughly before operating. 
  Follow the instruction. Never remove warning or informative labels  

  from the unit.

Содержание SMOKE-1500

Страница 1: ...ENGLISH SMOKE 1500 PRODUCT MANUAL Version 1 0...

Страница 2: ...dix B DMX Dip Switch Value Guide 16 CONTENTS If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Read the...

Страница 3: ...ct power Contact a service technician to determine safety for use Keep machine in flat position never put it in tilted place Before moving fog machine always drain fog fluid into the tank and tighten...

Страница 4: ...fore cleaning servicing or storing Never put any flammable material lipid gas perfume etc into the tank read the user manual thoroughly before operation Better use our high quality water based fog flu...

Страница 5: ...ocal dealer The wires in this mains lead are colored in accordance with the following code EU Green and Yellow Earthed E Blue Neutral N Brown Live L Warning This appliance must be earthed USA Green an...

Страница 6: ...tank Red ON Heating Red OFF Ready to use Red Flash Out of fluid Advanced oil level sensor detects shortage of oil and warns the pump to cut the oil supply automatically Aluminum die cast design funct...

Страница 7: ...LED Indicator F DMX 3 pin XLR Output G DMX 3 pin XLR Input H Control Socket Connection I DMX Dip Switch FDS1 OFF DMX 1CH ON DMX 3CH FDS2 No function J Power Switch K Fuse Holder L Electric Power Inpu...

Страница 8: ...ace the feeder tube with filter deep inside the full fog fluid tank C of figure1 Use only high quality water based fog fluid 5 Firmly attach the remote control mechanism to socket H of figure1 on the...

Страница 9: ...Ground 1 Ground 1 Ground 1 Ground 2 Cold 2 Cold 2 Cold 2 Cold 3 Hot 3 Hot 3 Hot 3 Hot 4 N A 4 N A 5 N A 5 N A XLR Pin Configuration Pin 1 Ground Pin 2 Data Compliment negative Pin 3 Data True positive...

Страница 10: ...tion Any of DMX Dip 1 9 ON Use DMX Dip switches 1 9 to set the unit to the desired DMX512 address Refer to the DMX value guide in Appendix B 1 Connect the DMX 512 controller cable to the input socket...

Страница 11: ...9 CH1 Volume 5 255 10 100 0 4 OFF CH1 CH2 CH3 Volume Interval Duration 5 255 10 100 0 255 10 250 s 0 255 1 10 s 0 4 OFF DMX 1CH MODE DMX 3CH MODE Figure 2 DMX Chart...

Страница 12: ...DMX Dip Switch 1 9 to OFF at this moment DMX for output mode used to control other fog machines connected to follow the synchronous action 2 Slave fogger After connecting in series set DMX address of...

Страница 13: ...ars as warm up arrives at fogging point indicating a finished heating time Besides SMOKE 1500 devises the low fluid sensor Red LED under tank bottom will automatically flash to warn low fluid supply T...

Страница 14: ...ntenance must be done by qualified person The fog liquid is not allowed to get dirty Be sure to always clean or replace the caps on the fog liquid vessel and tight the cover of the fog machine liquid...

Страница 15: ...n 18000 Warm Up time min 7 Fluid Consumption ml min 45 Date Connection 3P XLR Low Fluid Shutdown Yes Bracket or handle Both Voltage 230V 50Hz Dimensions mm LxWxH 418 220 209mm Weight kg 7 5kg Matching...

Страница 16: ...tinuous Fogging Press the button the fog machine emits fog continuously and the upped red LED will glow C Manual Fogging Press the button it allows the operation be con trolled manually After the mach...

Страница 17: ...tion knob Interval knob sets the amount of time in between every fog output and Volume knob is adjust the fog volume Duration and Interval knobs are effective at this moment TIMER button release up to...

Страница 18: ...For example standard DMX addresses for four SMOKE 1500 each of which has three channels see Figure 2 follow Address Value DMX Dip Switches ON Unit 1 1 1 Unit 2 4 3 Unit 3 7 1 2 3 Unit 4 10 2 4 Explana...

Страница 19: ...Save this instruction properly All the information is subject to change without prior notice...

Отзывы: