![Light-ink SMOKE-1500 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/light-ink/smoke-1500/smoke-1500_product-manual_1911785010.webp)
(8)
Function Dip Switch Selection:
FDS1: Channel Selection
OFF:
DMX 1CH
ON:
DMX 3CH
FDS2: No Function
Remote Control Operation (Any of DMX Dip 1-9 “OFF”)
For best result, use SMOKE-CONTROL timing controller.
1.
Firmly attach the remote control mechanism to socket (H; figure 1)
on the back of the unit.
2.
Plug mains power cord from the fog machine into appropriate
power supply socket. Wait about 7 minutes for heating element to
heat up.
3.
Refer to your controller manual for operation details. (Appendix A)
DMX Control Operation (Any of DMX Dip 1-9 “ON”)
Use DMX Dip switches 1-9 to set the unit to the desired DMX512 address.
Refer to the DMX value guide in Appendix B.
1.
Connect the DMX 512 controller cable to the input socket
(G of figure 1) of the fog machine unit. Make sure the signal cable
polarity is correct. Connect power lines. Your machine is now
ready for operation with your DMX controller.
2.
If desired, connect another fog machine: Plug one end of another
signal cable in to the output socket (F of figure 1) on the back of
the first SMOKE-1500; plug the other end of the signal cable to the
input socket (G of figure 1) on the back of the second SMOKE-1500.
Follow the same procedure to link more fog machine, if desired.