background image

Synjax Matrix Bar 12 

Matrix Effect Spotlight 

User Manual 

V 1.0

Содержание Synjax Matrix Bar 12

Страница 1: ...Synjax Matrix Bar 12 Matrix Effect Spotlight User Manual V 1 0 ...

Страница 2: ...Bar 12 Contents 1 Introduction 3 2 Safety instructions 4 3 Unpacking the device 6 4 Installation 6 5 DMX Connection 7 6 Mounting the device 8 7 Control Panel 8 8 Channel assignment 10 9 Service and cleaning 11 10 Information 12 2 ...

Страница 3: ...he manufacturer does not accept any liability for damage caused by not following these operating instructions or unauthorized changes to the device Please note that damages caused by manual changes to this device are not covered by the warranty ATTENTION This device is for professional use only Protection class IP 20 only for use in dry environment indoor Light Bright does not authorize the use of...

Страница 4: ...on the power cord Do not install the spotlight in such a way that people can trip over the power cord or step on it Make sure that the power cord can never be crushed or damaged by sharp edges Check the unit and the power cord from time to time Always refer servicing to qualified service personnel ATTENTION This light corresponds to protection class I Therefore this light must be connected to a ma...

Страница 5: ... The openings should never be covered with fabrics or other objects so that the airways are blocked This unit must not be operated in an environment without adequate ventilation The device may only be operated when the housing is closed and all screws are tightened The device must always be secured with an additional safety device Make sure that the area underneath the spotlight is clear during in...

Страница 6: ...ist Connection in Germany Europe Connected loads voltage 100 240 V frequency 50 60 Hz power max 60 VA The electrical safety as well as the function of the device is only guaranteed if it is connected to a properly installed protective conductor system It is very important that this basic safety requirement is present In case of doubt have the electrical installation checked by a specialist The man...

Страница 7: ...ment Pin1 Ground Shielding Pin2 DMX Pin3 DMX The spotlight has a DMX in and DMX out connection Now connect the DMX output of your controller to the first spotlight Controller DMX Out Spotlight DMX In Then connect the first spotlight with the second spotlight and so on In some cases it is advisable to plug in a so called end plug end resistor XLR plug with a resistor of 120 Ohm between pin 2 and pi...

Страница 8: ...ht with a safety device that complies with the national regulations Use the safety eyelet on the device for this purpose 7 Control Panel The spotlight has a display to show the set parameters and four buttons to adjust them This control panel allows you to adjust all the parameters of the spotlight according to your needs Operation of the menu Each setting must be confirmed with ENTER The last set...

Страница 9: ... Program speed selectable from 1 16 AUTO AudI Automatic or sound mode dISP Direction of the display selectable CHXX DMX channel mode selectable The following modes are available 6 Ch 9 CH 84 Ch and 89 Ch Please refer to the table below for the corresponding DMX assignment 9 ...

Страница 10: ...55 Color Mix effect 8 88 Programm 0 15 No function 16 255 Saved effects 9 89 Speed 0 255 Speed of saved effects White Beam dimmer 1 3 0 255 Beam 1 0 100 Intensity 2 4 0 255 Beam 2 0 100 Intensity 3 5 0 255 Beam 3 0 100 Intensity 12 14 0 255 Beam 12 0 100 Intensity Color dimmer 13 15 0 255 Red 1 0 100 Intensity 14 16 0 255 Green 1 0 100 Intensity 15 17 0 255 Blue 1 0 100 Intensity 16 18 0 255 Red 2...

Страница 11: ...eaning is complete close all covers again with the corresponding screws and carry out a function test Please use only clean cleaning cloths or brushes and cleaning agents without alcohol to clean your device We recommend regular cleaning at least every three months Pay attention to damage to the device to parts of the device and to the connection cables If you notice any damage DO NOT use the devi...

Страница 12: ...d against the penetration of solid foreign bodies with a diameter of more than 12mm first code number 2 while it is sensitive to moisture splash and jet water During operation it is mandatory to connect the device to a power supply system equipped with a powerful grounding Class 1 device according to EN 60598 1 Furthermore it is recommended to protect the supply line of the equipment from indirect...