Liftkar PT I 44
Check
Interval
Comments
Checked by
Motor and casing
Check/adjust tension of drive chain
every 2 years
Play at the crank max. 3 mm or
function test (play at load change
above dead centre)
Check casing for cracks
every 2 years
Return stairclimber to manufacturer
if any defects are detected
Check bolts on casing and tighten
every 2 years Secure with Loctite 243
Check bolts on retention pins and tighten
if required
every 2 years
Check for running noise
permanently
Return stairclimber to manufacturer
if any defects are detected
Wheels and tyres
Check mounting bolts for eccentric arm
every 2 years
Check / clean brake contact surfaces
every 2 years
Check tyres for damage and replace if
required
permanently
Breaks
Check step edge wheels
every 2 years replace if required
Check braking point
permanently
Check brakes for ease of operation
every 2 years
Check spring pins
every 2 years tighten wheel hub to 21 Nm
Electronics and control unit
Check direction of travel and speed
every 2 years
Check single step mode and continuous
mode
every 2 years
Check function of LED displays
every 2 years
Return stairclimber to manufacturer
if defective
Check battery pack, battery pack holder
and connections
every 2 years
Check battery pack and charger for
mechanical damage
every 2 years
Return charger/battery pack to
manufacturer if any defects are
detected
Check thread on lever screw on
handlebar unit
every 2 years
Return stairclimber to manufacturer
if defective
Accessories for PT Adapt, seat unit for PT S, guides on PT Universal
Check all bolted connections and tighten
if required
every 2 years
Replace immediately if cracks are
detected
Check all hinged points and lubricate if
required
every 2 years
Replace immediately if
cracks/damage is detected
Check all accessories fitted and tighten if
required
every 2 years
Replace immediately if damage is
detected
Содержание 045 723
Страница 52: ...Liftkar PT I 52 NOTES CONTACT...