1.3.2 Type-Specific Data
Type
MFC 16
12
MFC 16
18
MFC 16
26
MFC 16
40
MFC 16
60
Motor Power
at n = 1270 - 1420 rpm
at n = 1420 - 1650 rpm
(kW)
up to 6
up to
6.5
6 - 8
6 - 8.5
7 - 10
8 - 11
9 - 16.5
9 - 18
16 -27.5
16 -28.5
Input Data
Input Fusing AFF
(A)
25
30
40
50
80
Input Current (Nominal)
(A)
13
16
23
34
52
Input Current (Peak)
(A)
18.5
26
37
55
88
Output Data
Output Voltage (Nominal)
(V)
3 x 0 ... 360
Output power (Nominal)
(kVA)
9.5
11
16
25
36
Maximum Output Power for 10
soconds
(kVA)
13.5
18
26
40
60
Output Current (Nominal)
(A)
15.5
18
27
42
60
Maximum Output Current for 10
seconds
(A)
22
30
43
67
100
Loss at Nominal Power
(W)
480
500
540
620
835
Efficiency
0.96
0.97
Mechanical Data
Dimensions Width
(mm)
339
363
Height
(mm)
493
658
Depth
(mm)
270
285
Minimum clearance above/below
(mm)
150 / 100
200 / 100
Ventilation requirements
(m3/h)
250
300
Weight
(kg)
26
27
27
29
39
Braking Resistor (External)
Convection cooling
For use with MFC 16 model:
MFC 16
12
MFC 16
18
MFC 16
26
MFC 16
40
MFC 16
60
Resistor value
(Ohm)
23
14
14
14
7
Thermal Continuous
Performance PD
(kW)
1,5
3
3
4
6,5
Peak Performance for 2 secs.
(kW)
4
6
10
12
18
Safety Precaution
IP 20
Mimimum Clearance, sides and
above
mm
200
Maximum Ambient Temperature
(oC)
45
Maximum Operating Altitude
(m)
1000
The right to alter Technical Specifications is reserved
Содержание MFC 16 12
Страница 12: ...Edition October 1997 12 2 5 3 Switching Sequence Diagramm...
Страница 16: ...Edition October 1997 16 4 3 Front View MFC 16 40...
Страница 17: ...Edition October 1997 17 4 4 Front View MFC 16 60...
Страница 18: ...Edition October 1997 18...
Страница 19: ...Edition October 1997 19 4 5 Circuit Wiring Diagram...