Lift-Rite,
Tel:
Toll Free from USA: 1-800-558-6012, Greene, NY 13778, Publication Number 1234959D ©2022 Dated 14 Sep 2022
30
Multi-Point Calibration
•
Push the
key for about 10 seconds.
•
After 3 seconds, the display shows the last entered pre-set tare value.
•
After 7 seconds, the display goes into the calibration mode.
•
The display shows the first calibration point with the pointer “e1” flashing.
•
Use the
and
keys to see the three earlier programmed values on the display. The pointer
moves through e1-3. “e1” is the first calibration point, “e2” the second, and “e3” the third.
•
Use the
and
keys to return to the first point.
•
The indicator shows the value of the first calibration point with the “e1” pointer flashing.
•
Load the weighing system with a known weight.
•
Press the
key to enter this weight onto the indicator.
•
The first segment starts flashing.
•
Use the
,
, and
keys to change all segments until the proper weight is entered.
•
Press the
key to return to calibration mode.
•
The “e1” pointer starts flashing.
•
Press the
key for 3 seconds to confirm the entered weight.
•
This calibration number counts down from “Adj 08” to “Adj“, the first calibration point is now
set.
•
Move to the second calibration point.
•
The display shows the pointer “e2” flashing.
•
Repeat the procedure for a second known weight. Be aware that the value of this weight has to
be higher than that of the first weight. If not, the display shows “ERR98” and returns to the
entry mode for the calibration point.
•
Repeat the procedure for the third known weight. Leave calibration mode by pressing the
or
key until “AP XX” is shown.
•
This number indicates the calibration sensitivity percentage, for example, “AP 07”.
•
Press the
key.
•
The display shows the value of the gravitation constant. Use the
,
, and
keys to
correct this for your location.
•
Press the
key to return to the standard weighing mode.