14
TORQUE III
4.4 User Programs:
There are three user defined programs U1, U2, U3
1.
User defined program set up
Press “PROGRAM” continuously in standby mode until window displays U1-U3. Press “MODE” to start setting
first segment, setup speed and incline by pressing “SPEED+” “SPEED-” AND “” “INCLINE-”. Press
“MODE” to finish first segment setting and to begin segment. Repeat this until all 10 segments have been
completed. The data will be permanently saved until it is overwritten via this process.
2.
Starting the user defined program
a.
Press the “PROG” button whilst in standby mode until the window displays U01-U03, press
START after setting the running desired running time for this program.
a. Alternatively you may press the START button immediately after you have finishing setting
up the user define program
3.
Instruction of user define program setting
Each program is divided into 10 segments. The machine can only be started when all the speed and incline are
finish set for each segment.
4.5. Heart Rate:
When holding the hand pulse with two hands, the pulse window will show your heart rate after 5 seconds. To
increase accuracy please check heart rate with the machine stopped and after keeping your hands on the
sensors for more than 30 seconds.
The heart rate data is for reference purposes ONLY
and should not be used for medical purposes.
5. Body Fat Test:
In ready state, continued to press the button to enter the program's index (FAT) detection capabilities, Press
“
mode
”
button into F-1
、
F-2
、
F-3
、
F-4
、
F-5 interface (F -1 sex, F-2 age , F-3,height, F -4 weight, and F-5
constitution, to detect), press "SPEED+", “SPEED-” "", “INCLINE-”could adjust the 01-04 parameters
setting, (the following table for reference), press
“
mode
”
button after setting, into F-5 body test interface,
hands clasped hand pulse five seconds will show you the health index and view your weight and height is
whether or not. Constitution index (fat) is evaluating a person in height and weight and is not in proportion, fat
applicable to any male and female, and together with other health indicators for the adjustment of the weight of
fat.
5.1 Data Display and Setting Range
Parameter Category
Default
Range
Mark
Sex (F-1)
0 (MALE)
0
—1
0= Male 1 = Female
Age (F-2)
25 Yrs Old
10
—99 Yrs Old
Height (F-3)
170cm
100
—220cm
Weight (F-4)
70kg
20
—150kg
5.2 BMI Reference
BMI
Fat Level
<19
Thin
19
—26
Normal
26
—30
Over Weight
>30
Fat
6. Power saving Function:
The system has power-saving features, in the standby mode if within 10 minutes without any key command input,
the system into Power mode, automatically turn off the display, and press any key to re-start the system.
7. Safety key Function:
Pull out the safety key, then the treadmill will stop immediately. All the windows display
“
OFF
”,
the buzzer will
make 3 sound
“
B
—
B
—”
, the treadmill will stop. Attach the magnet end of the safety key to the computer, the
treadmill will re-start again.
Содержание TORQUE III