lifeSMART 2 Plus LS-946C Скачать руководство пользователя страница 30

30

This device has been tested to meet the electrical and safety requirements of:  
IEC/EN 61010-1, IEC/EN 61010-2-101, IEC/EN 61326-1, IEC/EN 61326-2-6.

SPECIFICATIONS

Model No.:

 LS-946C

Dimension & Weight:

 96 (L) x 61 (W) x 26 (H) mm, 67.2 g

Power Source:

 Two 1.5V AAA alkaline batteries

Display:

 LCD with backlight

Memory:

 1000 measurement results with respective date and time 

External Output:

 Strip port cable

Auto electrode insertion detection
Auto sample loading detection
Auto reaction time count-down
Auto switch-off after 3 minutes without action
Temperature Warning

Operating Condition:

 10°C to 40°C (50°F to 104°F), between 10% 

and 85% R.H. (non-condensing) 

Meter Storage / Transportation Conditions:

 -20°C to 60°C (-4°F to 

140°F), between 10% and 93% R.H. (non-condensing) 

Strip Storage / Transportation Conditions:

 2°C to 30°C (35.6°F 

to 86°F) and 10% to 85% R.H. for Blood Glucose / β-Ketone / Total 

Cholesterol strips

Measurement Units:

 mmol/L

Measurement Range:

Glucose: 0.56 to 38.89 mmol/L (10 to 700 mg/dL)

β-ketone: 0.1 to 8.0 mmol/L

Total Cholesterol: 2.5 to 10.3mmol/L (100 to 400 mg/dL)

Expected service life: 

5 years

Operating Altitude:

 Up to 2000m, for indoor use

Degree of Pollution:

 Pollution degree 2

Содержание 2 Plus LS-946C

Страница 1: ...Owner s Manual Multi Functional Monitoring System LS 946C ...

Страница 2: ......

Страница 3: ...screening of diseases The test for hematocrit HCT as part of the system is intended for use in the in vitro quantification of packed red blood cell volume fraction in capillary whole blood as an aid in monitoring the status of total volume of red blood cells The test reading of hematocrit HCT is used only to determine whether the blood test sample is within the acceptable range of the Multi Functi...

Страница 4: ... of glucose β ketone total cholesterol in whole blood The glucose β ketone total cholesterol testing is based on the measurement of electrical current generated by the reaction of glucose β ketone total cholesterol with the reagent of the strip The meter measures the current calculates the glucose β ketone total cholesterol level and displays the result The strength of the current produced by the ...

Страница 5: ...ns thoroughly and practice the test Carry out all the quality control checks as directed 7 Keep the device and testing equipment away from young children Small items such as the battery cover batteries test strips lancets and vial caps are choking hazards 8 Use of this instrument in a dry environment especially if synthetic materials are present synthetic clothing or carpets etc may cause damaging...

Страница 6: ...ntrol Solution Test Be Performed 14 Performing a Control Solution Test 14 TESTING WITH BLOOD SAMPLE 16 Preparing the Lancing Device for Blood Testing 16 Preparing the Puncture Site 16 Performing a Blood Test 17 METER MEMORY 19 Reviewing Test Results 19 Reviewing Blood Glucose Day Average Results 19 DOWNLOADING RESULTS ONTO A COMPUTER 20 MAINTENANCE 21 Battery 21 Caring for Your Meter 22 Caring for...

Страница 7: ...7 SYSTEM TROUBLESHOOTING 24 Result Readings 24 Error Messages 26 Troubleshooting 27 DETAILED INFORMATION 28 SYMBOL INFORMATION 29 SPECIFICATIONS 30 ...

Страница 8: ...8 g a SET f l c d e b j k h i ...

Страница 9: ...ing other substances will lead to incorrect results If you are experiencing symptoms that are inconsistent with your blood glucose β ketone or total cholesterol test results and you have followed all the instructions given in this owner s manual contact your healthcare professional We do not recommend using this product on severely hypotensive individuals or patients in shock Please consult your h...

Страница 10: ... the meter on for testing Download test results with a strip port connection cable Display Screen Main Button M Enter the meter memory and silence a reminder alarm Test Strip Ejector Eject the used strip by pushing up this button SET Button S inside the battery compartment Enter and confirm the meter settings Battery Compartment 1 2 3 5 4 6 ...

Страница 11: ...r Cholesterol Symbol 15 14 16 17 13 12 14 13 12 11 1 15 3 7 2 4 5 6 10 ATTENTION The front side of test strip should face up when inserting test strip Test results may be wrong if the contact bar is not fully inserted into the test slot NOTE The LS 946C monitor should only be used with LS 946 Blood Glucose β ketone or Total Cholesterol Test Strips Using other test strips with this meter can produc...

Страница 12: ...esired time format 12h or 24h Press S 3 Setting the time With the HOUR MINUTE flashing in sequence press M until the correct hour minute appears Press S 4 Setting the buzzer With the buzzer displays press M to switch between On and OFF Press S 5 Deleting the memory With dEL and a on the display press M and select no to keep the results in memory then press S to skip To delete all the results press...

Страница 13: ... on the meter The screen will display a flashing Gen and KETONE For Total Cholesterol Testing The meter provides you with two modes for measuring General and QC You can switch between each mode by Congratulations You have completed all settings NOTE These parameters can ONLY be changed in the setting mode If the meter is idle for 3 minutes during the setting mode it will switch off automatically c...

Страница 14: ... kit please check the contents on your product box They can be purchased separately Please make sure you have those items needed for a test beforehand Performing a Control Solution Test To perform a control solution test you will need b c and d 1 Insert the test strip to turn on your meter Wait for the meter to display and GLU KETONE or CHOL 2 Press M to mark this test as a control solution test f...

Страница 15: ...CE Make sure to perform the control solution test in QC mode To avoid contaminating the control solution do not directly apply control solution onto a strip 4 Read and compare the result After counting down to 0 the control solution test result will appear on the display Compare this result with the range printed on your test strip vial and it should fall within this range If not please read the i...

Страница 16: ...tion has a significant influence on the accuracy of the blood glucose β ketone or total cholesterol value obtained Blood from a site that has not been rubbed exhibits a measurably different glucose β ketone or total cholesterol concentration than blood from the finger If the puncture site was rubbed prior to blood extraction the difference is significantly reduced Please follow the suggestions bel...

Страница 17: ...ze which is 1 0 microliter μL of volume for both the blood glucose and β ketone test 3 0 microliter μL of volume for the total cholesterol test Gently squeeze the punctured area to obtain another drop of blood Be careful NOT to smear the blood sample 4 Apply the sample k Gently apply the drop of blood to the absorbent hole of the test strip at a tilted angle Confirmation window should be completel...

Страница 18: ...health care professional or the local customer service for assistance 5 Read your result The result of your blood glucose test with HCT levels or the result of your β ketone total cholesterol test will appear after the meter counts down to 0 The blood glucose result with HCT levels or the β ketone total cholesterol result will be stored in your memory automatically 6 Eject the used test strip i Ej...

Страница 19: ...meter After the last test result press M again and the meter will switch off Reviewing Blood Glucose Day Average Results 1 Press and release M When appears on the display keep pressing M for 3 seconds until the flashing appears Release M and then your 7 day average result measured in general mode will appear on the display 2 Press M to review 14 21 28 60 and 90 day average results stored in each m...

Страница 20: ...oftware System please visit LifeSmart s website mylifesmart net au 2 Connecting to a personal computer Connect the strip port cable to a cable port on your computer With the meter switched off connect the other end of the strip port cable to the meter data port PC will appear on the meter display indicating that the meter is in communication mode 3 Data transmission To transmit data follow the ins...

Страница 21: ...the meter is turned off 1 Press the edge of the battery cover and lift it up to remove 2 Remove the old batteries and replace with two 1 5V AAA size alkaline batteries 3 Close the battery cover If the batteries are inserted correctly you will hear a beep afterwards NOTE Replacing the batteries does not affect the test results stored in the memory As with all small batteries these batteries should ...

Страница 22: ...eter Disposal A used meter should be treated as contaminated and may carry a risk of infection during measurement The batteries in this used meter should be removed and the meter should be disposed in accordance with local regulations The meter falls outside the scope of the European Directive 2012 19 EU EC Directive on waste electrical and electronic equipment WEEE Caring for Your Test Strips Sto...

Страница 23: ...romptly see a doctor for help For further information please refer to the test strip package insert Important Control Solution Information Use only Our control solution with your meter Do not use the control solution beyond the expiry date or 3 months after first opening Write the opening date on the control solution vial and discard the remaining solution after 3 months It is recommended that the...

Страница 24: ... Ketone Warning This is shown when your blood glucose result is equal to or higher than 13 3 mmol L 240 mg dL What to Do Check blood ketone if checking ketone is part of your diabetes management program 38 9 mmol L 700 mg dL MESSAGE WHAT IT MEANS 0 1 mmol L 0 1 to 8 0 mmol L 8 0 mmol L for total cholesterol test MESSAGE WHAT IT MEANS 2 5 mmol L 2 5 to 10 3 mmol L 10 3 mmol L Result Readings for gl...

Страница 25: ...otal Cholesterol Expected Values Total Cholesterol mmol L Desirable 5 1 Borderline High 5 1 6 1 High 6 2 A healthcare professional will discuss values that are specifically appropriate for each patient At least two measurements of cholesterol in separate occasions should be made before a medical decision is made since a single reading may not be representative of a patient s usual cholesterol conc...

Страница 26: ...sed test strip is inserted Repeat with a new test strip E t Appears when ambient temperature is above or below system operation range System operation range is 10 C to 40 C 50 F to 104 F Repeat the test after the meter and test strip are in the above temperature range E 0 E A E E Problem with the meter Repeat the test with a new test strip If the meter still does not work please contact the local ...

Страница 27: ...strip Repeat the test with a new test strip Apply sample only when flashing appears on the display Please contact customer services Troubleshooting 3 If the control solution testing result is out of range POSSIBLE CAUSE WHAT TO DO Error in performing the test Control solution vial was poorly shaken Expired or contaminated control solution Control solution that is too warm or too cold Defective tes...

Страница 28: ...d 1 5 mmol L this may indicate development of a problem that could require medical assistance Follow your healthcare professional s instructions If your β Ketone result is higher than 1 5 mmol L contact your healthcare professional promptly for advice and assistance You may be at risk of developing diabetic ketoacidosis DKA Wiggam MI O Kane MJ Harper R Atkinson AB Hadden Dr Trimble ER Bell PM Trea...

Страница 29: ...d must be returned to a collection point for recycling electric and electronic devices according to local laws If it contains batteries the batteries should be removed and disposed in accordance with locations for separate collection of spent batteries SYMBOL REFERENT Manufacturer CE mark Caution Humidity limitation CE mark RoHS compliance Catalogue number Batch code Serial number ...

Страница 30: ...nt down Auto switch off after 3 minutes without action Temperature Warning Operating Condition 10 C to 40 C 50 F to 104 F between 10 and 85 R H non condensing Meter Storage Transportation Conditions 20 C to 60 C 4 F to 140 F between 10 and 93 R H non condensing Strip Storage Transportation Conditions 2 C to 30 C 35 6 F to 86 F and 10 to 85 R H for Blood Glucose β Ketone Total Cholesterol strips Me...

Страница 31: ......

Страница 32: ...till send data via a Bluetooth dongle sold separately This can send your result data to your smartphone app via Bluetooth technology The smartphone app is free to download for both Android and iOS platforms Please search for Lifesmart Sugar CheQ for both iOS and Android The other advantage is our online cloud platform BodyLog365TM Your smartphone app can upload your results data automatically to B...

Отзывы: