MAINTENANCE AND CARE

How to check for cartridge damage

The ultra filtration membranes have been 

integrated into a robust cartridge and 

have been designed for a long service 

life. However, if treated incorrectly, the 

cartridge is liable to break.

The membrane integrity check should be 

performed every time the bottle has been 

subjected to shock or when you suspect 

damage may have occurred to the bottle.

1

 CAUTION

Do not subject the bottle to shock 

or misuse the bottle by inserting 

objects into the cartridge. 

Membrane Integrity check

•  Unscrew and remove the pump base 

from the bottle. Fill with water through 

the blue pre-filter sponge to within 1 

inch/2.5cm of the brim. Screw the pump 

base back into place.

•  Hold the bottle in the vertical, upright 

position with the screw top facing 

upwards for the duration of the 

membrane integrity check.

•  Open the snap-fit lid and pump 4 - 6 

times. 

•  Open the nozzle with clean hands to 

allow the water to flow. Apply another 4 

- 6 pumps when water flow slows down 

to drain the bottle of all of its water.

•  If the bottle spits water from the nozzle 

and water does not flow freely then 

air is being expelled from the nozzle 
along with water. 

1

  This means that 

the cartridge is damaged. Stop using 

the bottle and replace the cartridge 

(see page 13 for how to install a new 

cartridge). 

•  If water isn’t spitting from the bottle, 

but flow rate is slower than normal 

despite the bottle being 1/4 full at 

either the horizontal or vertical position, 

clean the bottle as dirt and debris may 

be causing slower flow rate.  If the 

bottle has been cleaned and water 

flow remains slower than normal, the 

cartridge may be reaching the end of 

its life (see page 19 for FAILSAFE™ 

TECHNOLOGY).

Содержание bottle

Страница 1: ...Invented Designed and Manufactured in Great Britain Patented Worldwide FILTER Clean Water Instantly Filters all viruses bacteria cysts all waterborne pathogens INSTRUCTION MANUAL SLI0013 1...

Страница 2: ...e to filter down to 15 nanometres 0 015 microns LIFESAVER systems filtration technologies complies with all British US and European Drinking Water Regulations for Microbiological Reduction as tested a...

Страница 3: ...tenance and Care 10 How to clean the bottle 12 How to check for cartridge damage membrane integrity check 13 How to install a new cartridge 14 How to replace the nozzle 15 Shelf life 16 Service life 1...

Страница 4: ...through the cartridge which removes this glycerin Glycerin is a natural food source and whilst the presence of glycerin is not harmful you should not drink the water used for priming the bottle It is...

Страница 5: ...m and screw the pump base back into place 3 Pop open the snap fit lid then open the nozzle with clean hands or teeth hold the bottle over a sink or drain Turn and unlock the pump handle and pump the b...

Страница 6: ...d closed to keep the nozzle clean and free from contamination 2 Open the snap fit lid and pump a maximum of 4 6 times 1 Unscrew and remove the pump base from the bottle Fill with water through the blu...

Страница 7: ...pressurise the bottle which will result in the product becoming over stressed To release pressure from the bottle unscrew the pump base slowly by turn until you hear a hiss sound Hold on to the pump b...

Страница 8: ...shell Replaceable UF cartridge Removable strap Included in some models Twist lock pump handle Anti slip base LIFESAVER 15nm ultra filtration membrane Chew proof replaceable drinking nozzle Removable p...

Страница 9: ...already installed remove and discard this first 1 Now reassemble the bottle Turn the bottle shell to the vertical down position with the screw top facing downwards and insert the bottle cartridge Twis...

Страница 10: ...a new O ring Over the life of the cartridge dirt and debris will build up on its surface To reduce this build up clean the bottle on a regular basis How to clean the bottle whilst outdoors With the sn...

Страница 11: ...cartridge during cleaning Soak the cartridge in a basin of warm water for 30 minutes Gently move the cartridge through the water to dislodge any dirt or debris 2 Rinse the cartridge with clean runnin...

Страница 12: ...ght position with the screw top facing upwards for the duration of the membrane integrity check Open the snap fit lid and pump 4 6 times Open the nozzle with clean hands to allow the water to flow App...

Страница 13: ...ater and drain for 1 hour Remove the new cartridge from its packaging Ensure that the white flat seal is seated on the top of the cartridge shoulder 2 Now reassemble the bottle Turn the bottle shell t...

Страница 14: ...se Maintaining the pump The bottle s pump has been designed for high workloads Over time it is possible for the pumping action to become stiff To maintain the pump Unscrew and remove the pump base fro...

Страница 15: ...an be left stored for a further 3 years before priming is required In total providing a 13 year shelf life Standard packaged activated carbon filter An activated carbon filter if sealed in its origina...

Страница 16: ...tle against extreme temperatures Keep the membranes of the cartridge hydrated by storing at least 1 inch 2 5 cm of water in the bottle at all times whilst keeping the bottle sealed with the pump nozzl...

Страница 17: ...to install an activated carbon filter If the bottle has been stored for 12 months or more without use fit a new blue pre filter sponge and wash the nozzle in warm detergent solution before re use How...

Страница 18: ...erformance and Technical data page 20 Transporting your LIFESAVER bottle When taking the bottle on an aeroplane ensure that Release pressure from the bottle by unscrewing the pump base slowly by turn...

Страница 19: ...a greater number of pumps are required to induce water flow There will come a point at which despite the recommended maximum number of pumps water does not flow Before you install a new cartridge che...

Страница 20: ...mpliance Water Supply Water Quality Regulations 2000 LIFESAVER bottle EU compliance European Drinking Water Directive Council Directive 98 83 EC LIFESAVER bottle WHO compliance Guidelines for Drinking...

Страница 21: ...u could potentially do this up to four times before the salts levels become dangerous However it is recommended that you seek alternate water sources before using the LIFESAVER bottle in this way FAQ...

Страница 22: ...the pump tube See page 14 Q I am finding it difficult to unscrew the base A This could be due to over pressurisation or over tightening of the base To help resolve this leave the teat in the open pos...

Страница 23: ...aterials and workmanship Should your LIFESAVER bottle prove defective within 2 years from the date of purchase you should return it to the retailer that you originally purchased it from LIFESAVER syst...

Страница 24: ...ial property rights must be observed 2007 2014 LIFESAVER systems All Rights Reserved Patents registered designs Pending and granted LIFESAVER is a registered trade mark The following are trademarks of...

Отзывы: