replacing your activated carbon 
filter

The activated carbon filter is made of 
high specification activated carbon which 
reduces a broad spectrum of chemical 
residues including pesticides, endocrine 
disrupting compounds, medical residues 
and heavy metals.

It is designed to last for approximately 
250 litres.

1. Empty LIFESAVER bottle of water.
2.  Install pre-filter disc in base of bottle 

and firmly screw up base.

3. Pump the handle 30 times.*
4. Unscrew the cap.
5.  Unscrew the old activated carbon filter 

and replace with a new one.

6. Firmly screw up the cap.
7. you may now slowly unscrew the base. 
8.  If this proves difficult leave the teat in 

the open position for a few minutes and 
try again.

After any trip and or when storing 
LIFESAVER bottle the activated carbon 
filter should be removed and discarded. 
Only replace with a new one immediately 
before your next trip.

MAINTENANCE

 AND

 CARE

UK

iMPOrTaNT!

Do not replace your carbon 
filter in the field unless 
absolutely necessary. When 
replacing the carbon filter you 
must follow these instructions. 
Failure to do so may cause 
contaminated water to pass 
through to the drinking water 
side.

Leaving the activated carbon 
filter inside the bottle whilst in 
long term storage may cause 
microbiological growth to 
occur. This will not have come 
from the bottle but may come 
from the user’s saliva. Always 
remove and discard the 
activated carbon filter when 
storing LIFESAVER bottle 
long term.

13

*

iMPOrTaNT!

If you do not pump the handle 30 times the 

cartridge will disengage from the seal and 

you risk contaminating the clean water side of 
the bottle.

Do not over tighten the 
activated carbon filter as 
this risks damage

Содержание 4000UF

Страница 1: ...INSTRUCTION MANUAL bottle 4000UF 6000UF...

Страница 2: ...is without the aid of any foul tasting chemicals like iodine or chlorine As I pointed out to a friend one day using chemicals to kill bacteria is not always effective and anyway all you are doing is d...

Страница 3: ...ce 8 Maintenance and Care of your LIFESAVER bottle 8 Front side washing at home in the field 10 Installing changing the UF cartridge 12 Using the pre filter 13 Replacing the activated carbon filter 14...

Страница 4: ...e ultra filtration membranes pump tube replaceable activated carbon filter replaceable UF cartridge Lifesaver bottle 750 ml capacity protective sleeve membrane protection grills removable base contain...

Страница 5: ...nue to over pump the bottle teat will open This is a safety feature In order to maintain the quality of the membranes after manufacture a small amount of glycerine is used to coat their surface Primin...

Страница 6: ...p the membranes wet When storing the LIFESAVER bottle between uses trips you should leave a small amount of water within the bottle 25 ml or so This will keep the membranes inside the cartridge wet an...

Страница 7: ...e life of your LIFESAVER bottle IMPORTANT Do not allow grit sand or other abrasive matter to enter the bottle If this happens it should be removed Abrasive matter remaining in the bottle will cause th...

Страница 8: ...cartridge will last up to a further 2 years dependent upon usage conditions Please check the end of shelf life date on your product Front side washing LIFESAVER bottle Over the life of the membranes p...

Страница 9: ...ap fit lid 3 THIS IS VERY IMPORTANT as it prevents contaminated water from entering the clean water area within the cartridge If you fail to do this you risk contaminating the safe water area of the c...

Страница 10: ...ough to meet your requirements As the LIFESAVER cartridge has been designed for exceptional service life it is rare that you will need to change the cartridge whilst in the field However should it be...

Страница 11: ...hilst holding the cartridge in place inside the bottle with one hand remove the safety seal from the cartridge with the other hand 4 Whilst holding the cartridge firmly in place screw the cap firmly b...

Страница 12: ...and other debris these should be washed free from the pre filter disc before re inserting If the hole is taking a while to close up simply remove the pre filter disc place in water and squeeze it a co...

Страница 13: ...AVER bottle the activated carbon filter should be removed and discarded Only replace with a new one immediately before your next trip maintenance and care UK IMPORTANT Do not replace your carbon filte...

Страница 14: ...on dot on the teat with the seam on the cap and firmly insert Maintaining the pump LIFESAVER bottle s pump has been designed for high workloads The o ring inside the pump is designed to glide easily u...

Страница 15: ...into a robust cartridge format and have been designed for long service life If treated incorrectly they are liable to break There are several reasons why a membrane might break DO NOT subject the bot...

Страница 16: ...the LIFESAVER bottle with fresh tap water and pump through to drain Dis assemble the bottle and remove the cartridge Remove the cap and remove the teat from the cap Clean all parts except the cartridg...

Страница 17: ...to our website www lifesaversystems com and buy online Q Where do I dispose of spent cartridges A The cartridge is made of recyclable plastic and should be disposed of at a recycling centre If this is...

Страница 18: ...ing Water Directive Council Directive 98 83 EC LIFESAVER bottle WHO compliance Guidelines for Drinking water Quality First Addendum 3rd Edition Membrane approvals compliances CE EPA NSF WHO WRAS DVGW...

Страница 19: ...he date of purchase you should return it to the retailer that you originally purchased it from LIFESAVER systems will at its sole discretion repair or replace the damaged item s You should ensure that...

Страница 20: ...t to the use of our products The quality of our products is guaranteed under our conditions of sale Existing industrial property rights must be observed LIFESAVER LIFESAVER bottle LIFESAVER cartridge...

Отзывы: