model no.
IFH12A-56
5
OPERATING INSTRUCTIONS
!! IMPORTANT
THIS HEATER IS FOR USE ON THE FLOOR ONLY.
Prior to operating the heater, ensure the electrical receptacle is of the configuration
and capacity appropriate for the heater. See receptacle configuration in OPERATING
INSTRUCTIONS. This heater is for use on 240 volts. The cord has a plug as shown in
#6. No adapter is available for this blade configuration, and none should be used. The
type of receptacle is a 240 volt grounding receptacle (NEMA 6-30R). When properly
installed, it provides a ground connection through the cord to the heater to protect the
operator from electric shock.
Receptacle: NEMA #6-30R 250V 30 Amps
Plug: NEMA #6-30P 250V 30 Amps
SPARE PARTS
1.
2 PCS fixed supports
2.
2pcs extension pipes
3.
2pcs bolts
.
SPARE PARTS
OPERATION
Step 1:
Take off the 2pcs bolt from the middle of left and right side of heater
(See below Image A)
Step 2:
To use the bolts in Step 1 to mount the 2pcs fixed supported in the
middle of left and right side of the heater (See Image B)
Step 3:
Make 2 holes in the ground, for the hole diameter pls reference to the
holes in the fixed supports, thenput the extension pipes in the 2 holes in the
ground.
Step 4:
Align the screw hole of the fixed support with the screw hole of
extension pipes plugged on the ground, And then fix the wohle heater with the
screws in the 2 parts by tools (See Image C)