background image

Troubleshooting 

Poor airflows 

1/4 in (6 mm) mesh on outside

hood is plugged

Filters plugged

Core obstructed

House grills closed or blocked

Dampers are closed if installed

Poor power supply at site

Ductwork is restricting HRV

Improper speed control setting

HRV airflow improperly

balanced

Clean exterior hoods or vents

Remove and clean filter

Remove and clean core

Check and open grilles

Open and adjust dampers

Have electrician check supply voltage

Check duct installation

Increase the speed of the HRV

Have contractor balance HRV

Supply air feels cold 

Outdoor temperature

extremely cold

Turn down the HRV supply speed

Placement of furniture or closed doors is

restricting the movement of air in the

home

If supply air is ducted into furnace return,

the furnace fan may need to run

continuously to distribute ventilation air

comfortably

Dehumidistat in not  

operating 

Outdoor temperature is above

15

o

C (59

o

F)

Check dehumidistat setting it

may be on OFF

Dehumidistat is functioning normally (see

Auto Dehumidistat Disable in this manual)

Set the dehumidistat at the desired

setting

Humidity levels are too 

high condensation is   

appearing on the     

windows  

Dehumidistat is set too high

HRV is not sized to handle a

hot tub, indoor pool etc.

Lifestyle of the occupants

Moisture coming into the home

from an unvented or unheated

crawl space

Moisture is remaining in the

washroom and kitchen areas

Condensation seems to form in

the spring and fall

HRV is set at too low a speed

Set dehumidistat lower

Cover pools, hot tubs when they are not

in use

Avoid hanging clothes to dry, storing

wood and  venting clothes dryer inside.

Fire wood may have to be moved outside

Vent crawl space and place a vapor

barrier on the floor of the crawl space

On humid days, as the seasons change,

some condensation may appear but the

homes air   quality will remain high with

some HRV use

Increase speed of the HRV

Humidity levels are too 

low 

Dehumidistat control set too

low

Blower speed of HRV is too

high

Lifestyle of occupants

HRV airflows may be

improperly balanced

Set dehumidistat higher

Decrease HRV blower speed

Humidity may have to be added through

the use of humidifiers

Have contractor balance HRV airflows

HRV and/or ducts frosting 

up 

HRV airflows are improperly

balanced

Malfunction of the HRV defrost

system

Note: minimal frost build-up is expected

on cores before unit initiates defrost cycle

functions

Have HVAC contractor balance the HRV

Condensation or ice build 

up in insulated duct to 

the   outside 

Incomplete vapor barrier

around insulated duct

A hole or tear in outer duct

covering

Tape and seal all joints

Tape any holes or tears made in the outer

duct covering, ensure that the vapor

barrier is completely sealed

Excess water in the bot-

tom of the HRV 

Drain pans plugged

Improper connection of HRV’s

drain lines

HRV is not level

Drain lines are obstructed

HRV heat exchange core is not

properly installed

Look for obstructions in the drain line

Look for kinks in the drain line

Excessive Vibration 

Dirt on fan wheels

Have a contractor service HRV

SYMPTOM 

CAUSE 

SOLUTION 

11 

Содержание max series

Страница 1: ...511 McCormick Blvd London ON Canada N5W 4C8 General Info Tech Support 1 855 247 4200 Online www lifebreath com MAX SERIES HOMEOWNERS GUIDE 69 MAX OWNERS 012616 ...

Страница 2: ...12 Model___________________________________ Serial Number____________________________ Dealer Contractor Information Dealer_________________________________ Installer________________________________ Telephone Contact_______________________ Installation Date_________________________ Register your HRV for warranty at www lifebreath com For any warranty information please contact Airia Brands 511 McCo...

Страница 3: ...tilation mode at low speed for low household activity levels or when the home is unoccupied This mode is useful when 20 40 mode is providing too much ventilation V Continuous Recirculation This mode continuously recirculates your household air no ventilation This mode is not applicable if your HRV is connected to a forced air system Recirculation Recirculates existing household air without introdu...

Страница 4: ...rs only when the outdoor air is dryer than the indoor air Your Lifebreath Digital Control has an adjustable Dehumidistat which can be set to achieve a further dehumidification effect from your HRV High speed ventilation will be initiated upon exceeding the Dehumidistat set point regardless of the mode and speed of operation Once the humidity in the house is reduced the HRV will revert back to its ...

Страница 5: ...d Button Press and release the 20 40 60 High Speed button to temporarily initiate HIGH Fan speed for 20 40 or 60 minutes Press once for 20 minutes twice for 40 minutes 3 times for 60 minutes and 4 times to disable The will appear on the screen and the corresponding section of the clock will flash to indicate the time interval selected When the timer runs out the unit will return to it s previous o...

Страница 6: ...at settings and set the unit into LOW fan speed Ventilation mode and a Dehumidistat setting of 40 Service Indicator A service indicator appears when the unit requires routine maintenance Refer to Maintenance Routine in this guide To reset the service indicator once routine maintenance has been performed press and hold the ON OFF button for 5 seconds Timers Depending on the type of HRV installation...

Страница 7: ... on the Timer to indicate either 20 40 or 60 minutes of high speed fan operation To cancel the call for high speed fan operation press the Select Button until the Status Lights are no longer illuminated Replacing the Battery When the battery on the timer needs to be replaced in the Wireless Timer the red LED Battery Indicator will illuminate To replace the battery first remove the Face Plate by pu...

Страница 8: ...Indicator LED s When the Repeater is positioned correctly a solid green LED will illuminate indicating the Repeater has a strong connection to the main wall control and may be moved farther away if necessary A flashing green LED means that the Repeater has a moderate connection to the main wall control The Repeater will function properly at this position but should not be moved farther from the ma...

Страница 9: ...utward Core may be snug but will slide out of the cabinet c Once removed from the cabinet remove filters d Install the clean filters e Install clean core in the cabinet Note Core installation label on the outer end of the core To Install the Clean Core a To reinstall the core first position the bottom of the core on the bottom support in the cabinet b Carefully align the core with the other 3 supp...

Страница 10: ...water and replace if worn bent or unable to clean 6 Clean Duct Work if Required The duct work running to and from the HRV may accumulate dirt Wipe and vacuum the duct once every year You may wish to contact a heating ventilation company to do this 7 General Maintenance Twice a Year Wipe down the inside of the cabinet with a damp cloth to remove dirt bugs and debris that may be present 10 ...

Страница 11: ...d fall HRV is set at too low a speed Set dehumidistat lower Cover pools hot tubs when they are not in use Avoid hanging clothes to dry storing wood and venting clothes dryer inside Fire wood may have to be moved outside Vent crawl space and place a vapor barrier on the floor of the crawl space On humid days as the seasons change some condensation may appear but the homes air quality will remain hi...

Страница 12: ... HRV cycles through the available speeds and tests the damper motor operation The HRV resumes operation at the selected mode and speed Approximately 60 seconds in duration Standby Speed 0 The HRV is on but fans are not running waiting for ventilation to be initiated by either an external control i e timer or the dehumidistat Set the main control to speed 0 to set the HRV in standby Timers These op...

Страница 13: ...ie le fonctionnement du moteur du registre Le VRC revient ensuite à son mode de fonctionnement antérieur et à la vitesse choisie après environ 60 secondes Mode d attente Vitesse 0 Le VRC est mis sous tension et attend que la ventilation soit actionnée par l intermédiaire d une commande externe par ex une minuterie ou du déshumidistat Réglez la commande principale à la vitesse 0 pour que le VRC soi...

Страница 14: ...éshumidistat plus bas couvrez la piscine et le hot tub quand vous ne vous en servez pas évitez d étendre du linge à sécher d emmagasiner du bois et de ventiler la sécheuse à linge à l intérieur vous devrez peut être sortir le bois de chauffage dehors aérez l espace sanitaire et mettez un pare vapeur sur le plancher de cet espace sanitaire par temps humide lorsque les saisons changent il pourrait y...

Страница 15: ...t trop usé faussé ou impossible à nettoyer 6 Nettoyez les canalisations au besoin Il pourrait y avoir une accumulation de saleté dans les canalisations reliées au VRC En plus de vous servir d un aspirateur essuyez les canalisations une fois par année Vous pourriez aussi confier cette tâche à une entreprise spécialisée en chauffage et climatisation 7 Effectuez un entretien général deux fois par ann...

Страница 16: ...peu serré il vous sera possible de le sortir de sa coulisse c Une fois que vous l avez sorti de l armoire enlevez les filtres d Remettez les filtres propres en place e Réintroduisez le noyau nettoyé dans l armoire de l appareil Remarque L étiquette d installation du noyau doit être à son extrémité extérieure Pour remette le noyau nettoyé dans l appareil a Placez d abord le bas du noyau sur son sup...

Страница 17: ...t positionné correctement une DEL verte s allume pour indiquer un signal fort entre le répéteur et la commande murale principale et qu il peut être déplacé plus loin si nécessaire Une DEL verte clignotante indique que le répéteur a un lien plus faible avec la commande principale le répéteur peut fonctionner correctement à cet endroit mais ne devrait pas être plus éloigné de la commande principale ...

Страница 18: ...emplacement éloigné dans la maison comme une salle de bains En appuyant sur le bouton select de la minuterie on enclenche le fonctionnement du ventilateur à haute vitesse Le témoin correspondant s allume sous les nombres qui indiquent soit 20 40 ou 60 minutes de fonctionnement du ventilateur à haute vitesse Pour annuler la demande de fonctionnement à haute vitesse appuyez sur le bouton select jusq...

Страница 19: ...Indicateur d entretien Un signal apparaît lorsque arrive une étape de maintenance régulière reportez vous à Entretien périodique dans ce guide Pour réinitialiser le rappel une fois la maintenance effectuée maintenez le bouton de marche arrêt enfoncé pendant 5 secondes Minuteries Selon le genre d installation à VRC vous pourriez profiter d une minuterie optionnelle dans divers endroits de la maison...

Страница 20: ...t Bouton réinitialisation Bouton haute vitesse 20 40 60 Fonctionnement du commande numérique DXPL02 Mise en marche de la commande Appuyez et relâchez le bouton Marche arrêt Le témoin s allume au dessus Réglage de la vitesse de ventilation Appuyez sur et relâchez le bouton du ventilateur pour sélectionner l une des vitesses de ventilateur 5 La vitesse du ventilateur s affiche à l écran à côté du sy...

Страница 21: ...ité excessive à l intérieur en déclenchant la ventilation à haute vitesse dès que le point de consigne réglable du Déshumidistat est dépassé Consultez la section portant sur la commande principale dans le Guide d installation pour savoir comment régler le Déshumidistat Étant donné qu on obtient un effet de déshumidification seulement lorsque l air extérieur est plus sec que l air intérieur la fonc...

Страница 22: ...ive parfois que des habitations soient câblées incorrectement Vous devez toujours vous assurer que l appareil est bien mis à la terre Attention À cause de notre programme continu de recherches et de perfectionnement des produits les caractéristiques les puissances nominales et les dimensions peuvent être modifiées sans préavis Consultez le www LIFEBREATH com pour les toutes dernières informations ...

Страница 23: ...__ Numéro de série ___________________________ Renseignements au sujet du concessionnaire et de l entrepreneur Concessionnaire ________________________ Installateur ____________________________ Téléphone Contact ____________ Date d installation ______________________ Pour enregistrer la garantie de votre VRC visitez le site www lifebreath com Si vous avez besoin d informations au sujet de la garan...

Страница 24: ...511 boul McCormick London ON Canada N5W 4C8 Information générale support technique 1 855 247 4200 En ligne www lifebreath com SÉRIE MAX GUIDE POUR LES PROPRIÉTAIRES 69 MAX OWNERS 012116 ...

Отзывы: