14
Options
99-186
Weatherhoods, Two - 6" c/w
1/4" mesh screen
99-130W
Remote Wall Mount Dehumidistat
Control 24 VAC only
99-RSK6
6” back draft damper
Side
Front
29.5"
19"
47.5"
6"
6"
®
C L E A N A I R F U R N A C E
14"
12"
4"
Top
29.5"
22"
19"
14"
Bottom
29.5"
19"
16"
Duct (coil)
Opening
Optional R/A
Opening
17.25"
Ventilation Supply
Air Inlet
Ventilation Exhaust
Air Outlet
22"
Return Plenum
Latches
Blower Section
(SERVICE CLEARANCE 1')
(SERVICE CLEARANCE 3')
Specifications
Model 40DHWDF
(Down Flow)
Core
Ventilation system has patented aluminum heat recovery core (standard) or an enthalpic energy
recovery core (optional) for energy-efficient ventilation. Enthalpic cores are recommended for
regions where the temperature does not drop below 25˚F (-4˚C).
Filters
Washable air filters in exhaust and supply air streams of ventilation section, 1" pleated in
return plenum side.
Case
Prepainted galvanized steel for superior corrosion resistance.
Dimensions & Clearances
1030
900
825
740
3 GPM
130
140
150
160
170
180
Water
Temp.
44.0
41.0
38.9
36.5
51.7
48.0
46.7
42.7
59.3
55.1
52.4
49.0
67.0
62.3
59.2
55.3
CFM @ .25"WG
74.8
69.4
66.0
61.7
82.5
76.6
72.8
68.0
4 GPM
130
140
150
160
170
180
48.0
44.1
41.7
38.7
56.2
51.7
48.8
45.5
64.5
59.3
56.0
51.9
72.8
66.9
63.2
58.6
81.2
74.6
70.4
65.3
89.6
82.3
77.6
72.0
5 GPM
130
140
150
160
170
180
50.5
46.1
43.5
40.0
59.1
54.0
50.9
46.9
67.8
61.9
58.3
53.7
76.5
69.8
65.8
60.5
85.3
77.8
73.3
67.4
94.1
85.8
80.8
74.3
890
790
740
660
40.7
38.0
36.5
33.8
47.7
44.5
42.7
39.6
54.8
51.0
49.0
45.5
61.9
57.6
55.3
51.3
CFM @ .5"WG
69.0
64.3
61.7
57.2
76.2
70.9
68.0
63.0
40DHW Output (MBH)
43.8
40.5
38.7
35.6
51.3
47.4
45.3
41.7
58.9
54.4
51.9
47.8
66.5
61.3
58.6
53.9
74.1
68.3
65.3
60.0
81.7
75.4
72.0
66.2
45.7
42.0
40.0
36.7
53.6
49.2
46.8
42.9
61.4
56.4
53.7
49.2
69.3
63.6
60.5
55.4
77.2
70.8
67.4
61.7
85.1
78.0
74.3
68.0
Note: Ventilation ports and return plenum opening available
off either side of cabinet. All units conform to CSA and UL Standards.
40DHWDF Output (MBH)
Model
40DHWDF
Voltage
120 VAC 60 Hz
Hp
1/3
Amps (total)
7
Water
1/2" Copper Soldered
Connections
Connection
Airflow (High)
.25 in wg
1030 CFM
.5 in. wg
890 CFM
Ventilation
100 - 140 CFM
Airflow
Effectiveness
70%
(Aluminum Core)
Total Efficiency
50%
(Enthalpic Core)
Net Weight
150 lbs.
Shipping Weight
165 lbs.
Warranty
Units carry a lifetime warranty on the heat
recovery (aluminum) core, a five year warranty
on the energy recovery (enthalpic) core and a
five year replacement parts warranty on all
other components.
0105