www.lifebreath.com
1
Pre-Installation Notes
Note
•
Due to ongoing research and product development, specifications, ratings, and dimensions are
subject to change without notice. Refer to
information.
Attention
•
Do not apply electrical power to the unit until after the completion of the installation (including
installation of low voltage control wiring).
•
Ensure the installation and wiring is in accordance with all local electrical codes.
•
Plug the unit into a standard designated (120 VAC) electrical outlet with ground.
•
The use of an extension cord with this unit is not recommended. If the installation requires
further wiring, have a licensed electrician make all the electrical connections. The
recommended circuit is a separate 15 A/120 V circuit.
Caution
•
Before installation, careful consideration must be given to how this system will operate if
connected to any other piece of mechanical equipment, i.e. a forced air furnace or air handler,
operating at a higher static. After installation, the compatibility of the two pieces of equipment
must be confirmed, by measuring the airflows of the ERV, by using the balancing procedure
found in this manual. Never install a ventilator in a situation where its normal operation, lack of
operation or partial failure may result in the back drafting or improper functioning of vented
combustion equipment
•
Unit must be installed level to ensure proper condensate drainage. Due to the broad range of
installation and operational conditions, consider the possibility of condensation forming on
either the unit or connecting ducting. Objects below the installation may be exposed to
condensate.
•
Do not install control wiring alongside electrical wire.
Warning
•
Disconnect the power from the unit before cleaning or servicing.
•
To prevent electrical shock, it is extremely important to confirm the polarity of the power line
that is switched by the safety (disconnect) switch. The hot line (black) is the proper line for
switching. Use either a voltmeter or test lamp to confirm the absence of a voltage between the
disconnect switch and ground (on the cabinet) while the door is open. This procedure must be
followed, as dwellings are occasionally wired improperly. Always ensure the proper grounding
of the unit.
•
Improper installation, adjustment, alteration, service or maintenance can cause property
damage, personal injury or loss of life. Installation and service must be performed by a
qualified installer or service agency.
Содержание 1230 ERV
Страница 1: ......
Страница 6: ...www lifebreath com 5 3 DIMENSIONAL DRAWINGS 330ERV Dimensions 530ERV Dimensions ...
Страница 7: ...www lifebreath com 6 3 DIMENSIONAL DRAWINGS 730ERV Dimensions 1230ERV Dimensions ...
Страница 32: ...www lifebreath com 31 18 WIRING DIAGRAMS 330ERV ...
Страница 33: ...www lifebreath com 32 17 WIRING DIAGRAMS 530ERV ...
Страница 34: ...www lifebreath com 33 17 WIRING DIAGRAMS 730ERV AND 1230ERV ...