A

DVANCED

M

ANUAL

I

NFLATE

Blood Pressure Monitor

Trilingual Instruction Guide – MODEL UA-705

E n g l i s h   •   F r a n ç a i s   •   E s p a ñ o l

UA705  6/3/05  12:46 PM  Page 1

Содержание UA-705

Страница 1: ...ADVANCED MANUAL INFLATE Blood Pressure Monitor Trilingual Instruction Guide MODEL UA 705 English Français Español ...

Страница 2: ...repair this monitor Because your UA 705 monitor contains delicate high precision parts avoid exposing it to extremes in temperature or humidity or to direct sunlight shock and dust A D Medical guarantees the accuracy of this monitor only when it is stored and used within the temperature and humidity ranges noted on page E 18 Clean the monitor and cuff with a dry soft cloth or a cloth dampened with...

Страница 3: ... Physicians agree that daily self monitoring of blood pressure is an important step individuals can take to maintain cardiovas cular health and prevent the serious consequences associated with undetected and untreated hypertension A D Medical has been manufacturing high quality healthcare products for over 20 years We are committed to providing you and your family with monitoring devices that prov...

Страница 4: ...YOUR BLOOD PRESSURE E 6 E 8 WHAT IS AN IRREGULAR HEARTBEAT E 9 ABOUT CUFF INFLATION METER E 9 ABOUT AVERAGE READING E 10 ABOUT PRESSURE RATING INDICATOR E 10 ABOUT MEMORY E 11 ABOUT BLOOD PRESSURE E 12 E 16 TROUBLESHOOTING E 17 SPECIFICATIONS E 18 CONTACT INFORMATION E 19 FRENCH INSTRUCTIONS F 1 SPANISH INSTRUCTIONS S 1 TABLE OF CONTENTS ...

Страница 5: ...ther expla nation Press exhaust button to release air Inflate cuff 30 to 40 mmHg above your normal systolic pressure Condition Cause The symbol shown while measure ment is in progress It blinks while detecting the pulse An irregular heartbeat or body move ment may have occurred Refer to page E 9 for more information on irregular heartbeats Previous measurement stored in MEMORY The battery power in...

Страница 6: ...th Line Toll Free 1 888 726 9966 E 3 MONITOR COMPONENTS ARM CUFF PROPER FIT RANGE INDEX MARK AIR HOSE DISPLAY START BUTTON AIR SOCKET AIR CONNECTOR PLUG EXHAUST RUBBER BULB BATTERY COVER AA BATTERY BATTERY COMPARTMENT ...

Страница 7: ... Rechargeable batteries will not work with this monitor LifeSource blood pressure monitors are easy to use accurate and digitally display full measurement readouts Our technology is based on the oscillo metric method a noninvasive blood pressure determination The term oscillation refers to any measure of vibrations caused by the arterial pulse Our monitor examines the pulsatile pressure generated ...

Страница 8: ...of your upper arm at the midpoint between the shoulder and elbow NOTE The LifeSource small cuff is not compatible with the UA 705 monitor Cuff Size Indicator On The Cuff Our cuff has an indicator which tells you whether you are using the correct cuff size or not Place the cuff on your arm see Page E 6 to learn how to put the cuff on correctly and if the Index Mark points within the Proper Fit Rang...

Страница 9: ...ortably with your left arm resting on a flat surface so that the center of your upper arm is at the same height as your heart 2 Lay left arm on the table palm up and thread cuff end through metal loop smooth side against arm Then position the tube off center toward the inner side of arm in line with the little finger 3 Pull the end of the cuff to tighten it fold back the extra material and fasten ...

Страница 10: ...aust valve to release all the air in the cuff 6 When the symbol is displayed begin cuff inflation by squeezing the inflator bulb repeatedly It may take a few seconds for the symbol to appear 7 Stop squeezing the inflator bulb when symbol disappears or until cuff pressure reaches about 30 mmHg to 40 mmHg above expected systolic pressure If inflating to a level above your expected systolic pressure ...

Страница 11: ...e excess air from the cuff If you move your arm before pressing the exhaust valve the result on the screen will be deleted The monitor shuts off automatically in about 30 seconds You can also press the START button to shut off the monitor 10 Remove cuff and make a note of your blood pressure and pulse rate on the chart in the back of the manual indicating date and time of measure ment Additional l...

Страница 12: ... all heartbeat intervals during the blood pressure measurement It is important that you relax remain still and refrain from talking during measurements NOTE We recommend contacting your physician if you see this symbol frequently The Cuff Inflation Meter is located on the left side of the display screen to tell you when the blood pressure monitor is inflating and deflating the cuff The Cuff Inflat...

Страница 13: ...surement corresponding to the JNC7 Classification NOTE Due to other risk factors e g diabetes obesity smoking etc in addition to your blood pressure measurement the Pressure Rating Indicator is approximate Please consult with your physician for interpretation and diagnosis of your blood pressure measurements NOTE Residents outside of the United States e g Canada and Mexico should refer to the WHO ...

Страница 14: ...ading displayed first You will then see the memory index number e g n04 of the most recent reading followed by the measurement Release the START button when you see the memory index number 2 The display will shut off automatically a few seconds after all of the readings are displayed To turn off the monitor at any time press the START button To clear the measurement history from memory remove the ...

Страница 15: ...diastolic pressure by 5 5 mmHg Sleeping can decrease systolic blood pres sure by as much as 10 mmHg Taking your blood pressure repeatedly with out waiting an interval of 5 minutes between readings or without raising your arm to allow blood to flow back to the heart can also affect it In addition to these factors beverages containing caffeine or alcohol certain medications emotional stress and even...

Страница 16: ...ypertension 140 159 or 90 99 Stage 2 Hypertension 160 or 100 SOURCE The Seventh Report of the Joint National Committee on Prevention Evaluation and Treatment of High Blood Pressure for Adults National Heart Lung and Blood Institute May 2003 WHO Classification Table for Adults outside of the U S e g Canada Mexico BP Classification Systolic mmHg Diastolic mmHg Optimal less than 120 and less than 80 ...

Страница 17: ...merican Heart Association recommends the following lifestyle suggestions to prevent or control hypertension Don t smoke Have regular physical Reduce salt and fat intake checkups Maintain proper weight Monitor your blood Exercise routinely pressure at periodic intervals Why Measure Blood Pressure at Home It is now well known that for many individuals blood pressure readings taken in a doctor s offi...

Страница 18: ...er inside the cuff is critical for the accuracy of the measurement This may give you a different reading A cuff too large will produce a reading that is lower than the correct blood pressure a cuff that is too small will pro duce a reading that is higher than the correct blood pressure There may also be other factors that can cause the difference in measurements Keys to Successful Monitoring Blood...

Страница 19: ...tablish your baseline meas urement you can start evaluating if your measurement has been affected based on things lifestyle changes or medication treatment How Do I Record My Blood Pressure Blood pressure readings are typically recorded with the systolic pressure writ ten first followed by a slash mark and the diastolic pressure For example 120 mmHg systolic and 80 mmHg diastolic measurements are ...

Страница 20: ...f time The healthcare professional may be using a different sized cuff Your measurements may be elevated by white coat hypertension NOTE If the actions described above do not solve the problem call 1 888 726 9966 In Canada 1 800 461 0991 Do not attempt to repair the device yourself Corrective action Replace battery with new one Alkaline battery recommended Reinstall the battery with neg ative and ...

Страница 21: ...n Hand held push button Power source 1 type AA 1 5 volt battery included Battery life Approximately 2 000 measurements Operating environment 50ºF to 104ºF 10ºC to 40ºC Less than 85 relative humidity Storage environment 4ºF to 140ºF 10ºC to 60ºC Less than 95 relative humidity Dimensions Width 3 2 81 mm Depth 4 2 105mm Height 2 2 54 mm Weight 4 3 oz 120 g without battery Blood pressure measurements ...

Страница 22: ...rce blood pressure product is covered by a Lifetime Warranty See warranty card for details For more information regarding use care or servicing of your blood pressure monitor contact In USA Distributed by A D Engineering Inc 1756 Automation Parkway San Jose CA 95131 USA LifeSource Toll Free 1 888 726 9966 www LifeSourceOnline com For Canadian Residents please contact Auto Control Medical 6695 Mill...

Страница 23: ...dicator is patent pending 2007 A D Medical All rights reserved Specifications subject to change without notice I MAN 705 Printed in China 09 05 IMPORTANT If You Need Assistance with the Set Up or Operation We Can Help Please call us FIRST before contacting your retailer at LifeSource Health Line 1 888 726 9966 Toll Free Auto Control Medical 1 800 461 0991 In Canada A specially trained representati...