![Life Racing D5 Скачать руководство пользователя страница 45](http://html.mh-extra.com/html/life-racing/d5/d5_system-manual_1908975045.webp)
PRO Spec
© Life Racing Ltd
Page 44 of 45
7
PRO Spec
7.1
Data logging
With the PRO spec, data logging becomes available. This allows logging data from the ECU to
be streamed and stored on a USB memory stick (ECU to dash Ethernet required), increasing
logging capacity. Logging settings follow those set in LifeCfg.
When a compatible USB device is connected, a white USB icon should appear (black on white
background). When streaming, this icon will turn green.
Symbol only shows on primary display pages such as road, race or stage.
*Note*
If the USB is green, the streaming needs to be stopped before unplugging the USB stick. To do
this press and hold the OK or DOWN button for about a second. The USB icon will change to
white indicating it's safe to remove. Failing to do this can corrupt logging files.
Data logging files are stored in .LRS format and are named with eight digits. The first four
numbers match the connected ECU serial number. The remaining four numbers are an index
number given by the dash. This number will update for every file saved, even on different
memory sticks. The index can be reset in the settings page.
To download logged data from USB, insert the memory stick into a PC. Logged data files will
need to be decoded using LifeData before viewing in LifeView. Select decode Streamed data to
decode a single file or decode Streamed data folder to decode an array of files. Decoded files are
automatically stored in the working directory as .LRD which can then be loaded in LifeView for
analysis.