7    MANUAL PROGRAMMING 

Press               for 5 seconds , the 5 leds will light up and then 
start blinking. 

Manual programming can be done with a button
connected to terminals 6 - 10 (Step-by-Step) or with
radio control previously memorized, page 7 cap.3.1.
Position the motors at 45 °.

7.1     CLOSING FINISHES LEARNING

During the flashing of the 5 LEDs give a command of
Step by step the leaf [2] must move first in closing,
when he arrives at the stop he has to stop and the Led of the 
Right goes on with fixed red light.
Give a second Step-by-Step command the leaf [1] must
move in closing, when it comes in batting it must stop and
the Left LED lights up with a fixed red light.

  

 

 

Give a Step-by-Step command the leaf [1] opens, al
reaching the point where you want to open also
the leaf [2] give a further step-by-step command.
The two wings now proceed in opening until they reach the
respective mechanical stops, the two red LEDs of left and 
right they remain in red light.

  

Give a Step-by-Step command the leaf [2] closes, al
reaching the point where you want to close also
the leaf [1] give a further step-by-step command.
The two doors proceed now in closing until they reach the
respective mechanical stops, the two red LEDs of left and 
right they remain in red light.

  

7.3    LEARNING CLOSING OFFSET

7.2    LEARNING OFFSET AND FINISHES   

The automation is now programmed in semi-automatic mode.

If the result obtained is not satisfactory, perform the
reset the control panel and restart from point 7.

START

Manual programming can be done with a button connected 
to terminals 6 - 10 (Step-by-Step) or with the previously 
memorized radio control, page 7 chap. 3.1.
Place the motors (leaves) at 45 °.

Hold the START button for 5 seconds, the 5 LEDs first light 
up and then flash.

CLOSING LIMIT SWITCH LEARNING

While the 5 LEDs are flashing, give a Step-by-Step 
command; the leaf [2] must move first performing a closure; 
when it reaches the mechanical stop it must stop and the 
Right LED lights up with a red steady light.
Give a second step-by-step command; the leaf [1] must 
perform a closure, when it reaches the mechanical stop it 
must stop and the Left LED lights up with a red steady light.

OPENING AND CLOSING PHASE SHIFT LEARNING

Give a Step-by-Step command; the leaf [1] starts opening; as 
soon as it reaches the point where you want to start opening 
leaf [2] give a further Step-by-Step command.
The two leaves now proceed to open until they reach their 
respective mechanical stops, the two red LEDs on the left 
and on the right remain with a steady red light.

OPENING PHASE SHIFT AND LIMIT SWITCHES LEARNING

CLOSING PHASE SHIFT LEARNING

Give a Step-by-Step command; the leaf [2] starts closing; as soon as 
it reaches the point where you want to start closing leaf [1] give a 
further Step-by-Step command.
The two leaves now proceed to close until they reach their 
respective mechanical stops, the two red LEDs on the left and on 
the right remain with a steady red light.

Automation is now programmed in semi-automatic mode.
If the result obtained is not satisfactory, carry out the
reset the control unit and start again from point 7.

LEARNING OF THE CLOSURE LIMIT SWITCH

LEARNING OF OPENING PHASE LAG AND LIMIT SWITCH

LEARNING OF CLOSING PHASE LAG

Содержание CT2 24 UNI DL

Страница 1: ...Rev 01 26 2018 LG CT2 24 UNI DL 24V F CONTROL UNIT FOR TWO LEAF GATES INSTRUCTIONS AND WARNINGS FOR INSTALLATION USE AND MAINTENANCE GB ...

Страница 2: ... manufacturer its maintenance Important safety instructions For personal safety it is important to follow these instructions Keep these instructions The device must be disconnected from the power supply during cleaning and maintenance operations and the replacement of components Do not allow children to play with the gate control devices Keep remote controls away from children Monitor the moving g...

Страница 3: ...3 mm 250 mm 184 min cm 40 5 3 4 1 2 GEBOX ASSEMBLY INSTRUCTIONS ...

Страница 4: ...ESCRIPTIONS AND WARNINGS FOR SECURITY and PRESCRIPTIONS AND WARNINGS FOR THE INSTALLATION All of the linking and connecting operations must be performed with the power source disconnected if the device is not visible a sign must be applied WARNING UNDER MAINTENANCE Stocking antenna input use RG58 50 Ohm cable ANTENNA For the imputs STOP OPEN CLOSE STEP BY STEP PHOTO BLINKER PEDESTRIAN Connections ...

Страница 5: ...der the terminal block show the entry state L7 and L11 are imputs N C and must be turned on they turn off when the corresponding imput is activated L8 L9 L10 are imputs N O must be turned off and they will automatically turn on when the corresponding imput is activated COMMON COMMANDS Relay PEDESTRIAN SIGNALING LED The LEDs under the terminal block indicate the state of the entrance L7 and L11 are...

Страница 6: ...press and keep pushed the button release after the central unit 2 CENTRAL UNIT PROGRAMMATION 2 1 TOTAL RESET ATTENTION START START START START To optimize energy consumption we have introduced the Energy Saving function After 10 minutes from the control unit setup the front panel LEDs turn off and the use of the keyboard is inhibited To reactivate it it is necessary to switch the control unit off ...

Страница 7: ...e control unit is fitted with a built in radio receiver with a 750 code memory and 2 channels with a 433 92 MHz frequency with LIFE Rolling Code and Auto code encoding Press the key fob selection button top left the left green LED under symbol and the first red dot A beside symbol will light up Hold down the P1 button on the transmitter that you want to pair to perform a total opening until all fi...

Страница 8: ...E CLOSE PAUSE MINIMUM 4 3 ADJUSTMENT TIME OF DECELERATION a Press the for 5 the Led green and red on the right will turn on ATTENTION The deceleration CAN T be completely eliminated in this phase the limit switch s push force will determine the Stop in the motor s run By pressing and you can adjust the value of he DECELERATION TIME MAXIMUM DEFAULT LEDS ON LEDS ON PAUSE TIME DECELERATION TIME CHIUS...

Страница 9: ...IMIUM DEFAULT LED ON SPEED MINIMUM 75 a Press the button and left red led will turn on By pressing or the speed can be adjusted MAXIMUM 100 DEFAULT 90 LED ON ATTENTION Based on the gate s structure and on its usage parameters such as sensitivity and speed mus be setted accordingly to the laws of the country By pressing or the sensitivity can be adjusted Wait 20 or press the button again to anticip...

Страница 10: ...interventions during movement Funcioning with PRESENT MAN Wait for 20 or press the again to exit programming mode No active function Wait for 20 or press the again to exit programming mode button to enter the OPTION MENU 1 then press it again in sequence to scroll through the available options The flashing LEDS indicate the position and the corresponding option By pressing button the function is a...

Страница 11: ...rogramming can be done with a button connected to terminals 6 10 Step by Step or with the previously memorized radio control page 7 chap 3 1 Place the motors leaves at 45 Hold the START button for 5 seconds the 5 LEDs first light up and then flash CLOSING LIMIT SWITCH LEARNING While the 5 LEDs are flashing give a Step by Step command the leaf 2 must move first performing a closure when it reaches ...