ONCE A DAY
1.
Wipe down upholstery with a mild soap and water or comparable all purpose cleaner.
2.
Visually inspect cables for wear at and around connections and along the entire
length of the cable. Always replace at first sign of wear.
ONCE A WEEK
1.
Visually inspect all hardware for loosening, tampering or wear.
2.
Check Jam Nut at top of weight stack for tightness.
3.
Inspect all accessories, connecting links, and carabiner clips for wear.
4.
Check condition of hand grips.
5.
Check cables for stretch and adjust as necessary by loosening the large Jam Nut on
top of the weight stack and by screwing in the Threaded Plug until cable is tight and
the weight stack pin goes in all holes easily.
6.
Inspect Shrouds for damage and clean as necessary.
ONCE A MONTH
1.
Clean Guide Rods with Break-Free
®
brand lubricant (part number SK50-P0005-
0000). Clean tops of bearings at stack and inspect for heavy buildup on rods below
the head plate. Lift half of stack and do a visual inspection, then clean as necessary.
2.
Inspect hardware on all machines and tighten any bolts or nuts that may have
loosened over the life of the product.
NOTES
Use polishing compound (such as car wax) and remove shoe scuffs from powder coated
surfaces as necessary.
CLEANING THE SHROUDS
Adherence to regular and proper cleaning procedures is recommended to preserve the appear-
ance.
MINIMIZE SCRATCHES
Wash the shrouds with an approved or compatible cleaner. Do not scrub brushes on the shrouds.
Fresh paint splashes, grease and smeared glazing compounds can be removed easily before
drying by rubbing lightly with isopropyl alcohol. Afterward, a warm final wash should be made.
LIFE FITNESS APPROVED CLEANERS
Two preferred cleaners have been approved by Life Fitness reliability experts: PureGreen 24 and
Gym Wipes. Both cleaners will safely and effectively remove dirt, grime and sweat from equip-
ment. PureGreen 24 and the Antibacterial Force formula of Gym Wipes are both disinfectants
that are effective against MRSA and H1N1.
PureGreen 24 is available in a spray which is convenient for gym staff to use. Apply the spray to
a microfiber cloth and wipe down the equipment. Use PureGreen 24 on the equipment for at
least 2 minutes for general disinfection purposes and at least 10 minutes for fungus and viral
control.
Gym Wipes are large, durable pre-moistened wipes to use on the equipment before and after
workouts. Use Gym Wipes on the equipment for at least 2 minutes for general disinfection pur-
poses.
Contact Customer Support Services to order these cleaners (1-800-351-3737 or
email: [email protected]).
24
Содержание OPTIMA OSFLY
Страница 1: ...OPTIMA SERIES STRENGTH Owner s Manual 05 25 10 8850901 REV B 2...
Страница 11: ...10 LABEL LOCATIONS OSHAA...
Страница 14: ...13 LABEL LOCATIONS OSFLY...
Страница 17: ...LABEL LOCATIONS OSLR 16 2x...
Страница 20: ...19 LABEL LOCATIONS OSLEC 2x...
Страница 23: ...22 LABEL LOCATIONS OSMP 2x...