6.6 C
LEANING THE
W
AX
N
OZZLE
The MESSAGE CENTER periodically displays a wax reminder message, if the use if WAX
REMINDER setting is enabled in the MANAGERS CONFIGURATION. When this message
appears, take the following steps:
A. Remove panel on right side to access nozzle (A).
B. Make sure that the unit is off, and the electrical plug has been removed from the wall.
C. Using a Phillips head screwdriver remove the two screws holding the right access panel in
place.
D. Carefully reach inside and while gently pushing the nozzle (A) into its brass holder body (C),
rotate the nozzle one-quarter turn clockwise. Make note of the orientation of the two flat sur-
faces on the top and bottom of the nozzle. When the nozzle is replaced after cleaning, the
flats must be on the top and bottom for nozzle to be correctly replaced.
D. Place nozzle in a container of hot water and let it sit for 10 minutes. Carefully remove noz-
zle. Water and nozzle will be hot.
CAUTION: If necessary, scrub with a medium soft bristle brush until there is no
further wax visible on the outside or inside of the nozzle.
Mise en garde. Si nécessaire, frottez la buse avec un brosse moyennement douce
jusquà ce que toute trace de cire ait disparue à lintérieur comme à lextérieur.
E. Dry nozzle with a lint free towel and reinsert with ¼ turn counterclockwise.
44