Setup
Read the entire manual before setting up the LIFE FITNESS Elevation GSC Trainer.
Electrical Power Requirements
LIFE FITNESS Elevation GSC Trainer require an AC power supply according to the electrical configurations listed in the
chart below.
Rated Current (Amps)
Frequency (Hz)
Supply Voltage
3.0
50 / 60
100
3.0
50 / 60
110
3.0
50 / 60
120
2.5
50 / 60
200
2.5
50 / 60
220
2.5
50 / 60
230
2.5
50 / 60
240+
NOTE:
Do not modify the plug provided with this product. If the plug does not fit into an available electrical outlet,
have a proper outlet installed by a qualified electrician.
Choosing and Preparing Site
Before assembling the unit, verify the chosen site meets the following criteria:
•
Area is well lit and well ventilated.
•
Surface is structurally sound and properly leveled.
•
Free area for access to unit and emergency dismount. Minimum clearance is 23.6 inches (0.6 meters).
•
Adjacent units may share the free area.
Free Area
23.6”, 0.6m
1
It is the responsibility of the facility owner/owner of the equipment to ensure that there is appropriate clearance around each
machine to allow for safe use and passage.
In compliance with the ADA (American Disabilities Act) there must be clear floor space of at least 30 by 48 inches and be
served by an accessible route for at least one of each type of exercise equipment. If the clear space is enclosed on three
sides (e.g., by walls or the equipment itself), the clear space must be 36 by 48 inches.
All other machines must have a clear floor space of 23" for all access point on the machine.
The dimensions stated in the assembly instructions of this manual include the maximum foot print (in use) dimensions.
Minimum clearance of 12” (30 cm) between units for proper wireless heart rate signal operation.