CAUTION!

   

Exceeding   generators   wattage/amperage   capacity   can   damage   generator   and   /or   electrical   
devices   connected   to   it.   

 

Start   the   generator   and   let   the   engine   rpm’s   stabilize   before   connecting   electrical   loads.   

 

Connect   all   electrical   loads   with   the   device   in   the   off   position.   

 

Turn   off   electrical   loads   before   shutting   off   generator   engine.   

   

WARNING!

   

   

Rapid   recoil   of   starter   cord   (kickback)   may   pull   hand   and   arm   forward   
toward   engine   at   a   rapid   rate.   

Broken   bones,   bruises,   sprains,   and   fractures   may   result.   

 

When   starting   engine,   pull   cord   slowly   until   tension   is   felt,   and   then   pull   rapidly   to   avoid   
kickback.   

 

Never   start   or   stop   engine   with   electrical   devices   plugged   in   and   turned   on.   Doing   so   is   
hazardous   and   will   damage   generator.   

WARNING!

   

   

Generator   produces   powerful   voltage!   
Only   a   licensed   electrician   can   safely   
connect   generator   to   existing   utility   

hookups.   Failure   to   isolate   generator   from   
electrical   grid   can   result   in   death   to   utility   
workers   as   well   as   others.   

 

When   using   generator   as   backup   power,   notify   utility   company.   Use   approved   
transfer   equipment   to   isolate   generator   from   electric   utility.   

 

Do   NOT   operate   generator   while   exposed   to   rain   or   other   wet   conditions.   

 

Do   NOT   handle   generator   when   in   contact   with   water.   

 

Do   NOT   contact   bare   wires   or   receptacles.   

 

Do   inspect   all   electrical   cords   for   damage   and   discontinue   from   use   any   damaged   or   
excessively   worn   cords.   

 

Do   NOT   allow   unqualified   persons   to   operate   or   service   generator.

   

Содержание LF3750

Страница 1: ...3 7 5 0 4 0 0 0 E P L G E N E R A T O R S O WN E R SMA N U A L...

Страница 2: ...Manual LF3750 LF3750 CA LF4000EPL LF4000EPL CA PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATING YOUR NEW PORTABLE GENERATOR E Indicates this unit is equipped with Electric Start CA Indicates this un...

Страница 3: ......

Страница 4: ...Specifications 5 Safety Instructions 7 Controls and Features 11 PRE OPERATING INSTRUCTIONS 13 Assembly 13 Battery Specifications 15 Generator Setup 16 Operation of Generator 19 Storing the Unit 23 Mai...

Страница 5: ...or to operation Keep this Owner s Manual for assistance in the future such as proper maintenance schedules and tips to prolong the life and effective use of your unit If you require assistance please...

Страница 6: ...ster Circuit Breaker Manufacturer LIFAN LIFAN Model LF168F2I13111 Recoil LF170FI13111 Recoil Maximum Horsepower MHP 6 5MHP 7 MHP Engine Displacement 196cc 211cc Starting System Recoil Recoil Electric...

Страница 7: ...1 ea Spark Plug Wrench 1 ea 1 ea Mobility Wheel Kit Available Yes Battery not included N A 12V 100cca min 5 25 lx3 w 3 Automativ Voltage Regulator 866 741I7464 Van Buren AR 72956 2205 Industrial Park...

Страница 8: ...xide can cause nausea or death ONLY operate generator outdoors Exhaust gas must be prevented from entering confined areas Direct exhaust gas away from windows doors ventilation and other openings Do n...

Страница 9: ...is felt and then pull rapidly to avoid kickback Never start or stop engine with electrical devices plugged in and turned on Doing so is hazardous and will damage generator WARNING Generator produces p...

Страница 10: ...f position Disconnect spark plug wire before transport or service WHEN STORING FUEL OR EQUIPMENT CONTAINING FUEL Store away from furnaces stoves water heaters clothes dryers or other appliances that h...

Страница 11: ...ter is required under section 4442 of the California Public resources code WARNING Unintentional sparking can result in fire or electrical shock WHEN TESTING FOR ENGINE SPARK Do NOT check for spark wi...

Страница 12: ...LIFAN Power USA 2205 Industrial Park Road Van Buren AR 72956 866 471 7464 www lifanpowerusa com 11 Controls and Features Read this Owner s Manual Completely and Carefully before Operating Generator...

Страница 13: ...oil Starting Handle Pull Handle to Rotate Engine for Starting 10 Fuel Cock Valve Turn to OFF to Terminate Fuel Delivery to Engine 11 Air Cleaner Check Maintenance Schedule for Service Intervals 12 Cho...

Страница 14: ...wer Cord with Plug Alligator Clips o 1 ea Nema14 30 Male Twist Lock Plug o RV Adapter Plug for 120 Volt 30amp Service Owner s Manual and Warranty Card Wheel Kit LF4000EPL LF4000EPL CA Only o 2 ea Neve...

Страница 15: ...rections NOTE Install Wheel Kit BEFORE Filling the Generator with Fuel or Oil Never Tip a Unit that contains Fuel or Oil 1 Tip Generator so Engine End is up 2 Slide Axle through both Mounting Brackets...

Страница 16: ...th the manufacturer s model number with the brand battery available at your local retailer BATTERY SPECIFICATIONS Generator Model Length inch Width inch Amp hrs DC Voltage Volts LF4000EPL 5 25 in 3 in...

Страница 17: ...ilure and void warranty ADD ENGINE OIL Refer to the diagrams below 1 Place generator on level surface 2 Clean area around Oil Hole Dipstick Plug Unscrew Oil Hole Dipstick Plug 3 Fill with appropriate...

Страница 18: ...h a fuel stabilizer or drained if the generator will not be started for thirty 30 days If using a fuel stabilizer follow the manufacture s recommended instructions for use Always use stabilizer with a...

Страница 19: ...to Air Cleaner Maintenance in the Maintenance section of this Owner s Manual to ensure Air Cleaner Element is in operable condition GROUNDING THE GENERATOR Refer to Controls and Features section 1 Con...

Страница 20: ...CAUTION Never start or shutoff the generator with electrical loads connected and in the operational mode on switch activated Starting or shutting off the generator with electrical loads activated may...

Страница 21: ...0 Volt loads to the 240 Volt receptacles Always plug appliances into the generator with appliance in its OFF position 3 Plug in 12V DC load to the DC receptacle DC and AC power may be used simultaneou...

Страница 22: ...CY TIME VFT METER The LF3750 LF3750 CA LF4000EPL and LF4000EPL CA models include a Voltage Frequency Time VFT Meter The VFT Meter has four 4 modes Start Up Mode 1 The run time for the cycle displayed...

Страница 23: ...gine USAGE IN HIGH ALTITUDE REGIONS In regions with high altitude the standard carburetor produces overly dense combinations of fuel and air which result in decreased engine performance and increased...

Страница 24: ...e section Do NOT re fill with oil until ready to use again 5 Remove the Spark Plug in accordance with the Spark Plug Maintenance in the Owner s Manual s Maintenance section Spray a lubricant such as W...

Страница 25: ...ment Product Check your engine oil level prior to each use 1 Start your engine and let it warm up to get the oil warm and thinner Turn the engine On OFF switch to the OFF position Turn Fuel Valve to t...

Страница 26: ...L MUST BE CHANGED ON A REGULAR BASIS FOR PROPER OPERATION AND RELIABILITY AND TO ALSO MAINTAIN THE WARRANTY ON THIS PRODUCT AIR CLEANER MAINTENANCE 1 Remove the clip item 9 in Air Cleaner A below or t...

Страница 27: ...ENANCE NOTE Periodically you can get sediment or trash in your Carburetor Bowl Use the following procedures to clean 1 Turn the fuel cock valve to the OFF Position 2 Remove the carburetor bowl by remo...

Страница 28: ...npowerusa com 27 Maintenance continued FUEL SYSTEM MAINTENANCE continued diagram below and either clean or replace the fuel filter element Re assemble the fuel filter element refer to Fuel Filter Elem...

Страница 29: ...r USA Toll Free 1 866 471 7464 or take your unit to an authorized Service Center NOTE Periodically on the initial start up or after the unit has been stored for a long period of time the float for the...

Страница 30: ...OT operate your power equipment within five 5 feet of any flammable materials 5 When refueling the power equipment never smoke or refuel near any flame or ignition devices Never refuel while the unit...

Страница 31: ...LIFAN Power USA 2205 Industrial Park Road Van Buren AR 72956 866 471 7464 www lifanpowerusa com 30 Wire Diagram LF3750 L F3750 CA Wiring D iagram...

Страница 32: ...LIFAN Power USA 2205 Industrial Park Road Van Buren AR 72956 866 471 7464 www lifanpowerusa com 31 Wire Diagram continued LF4000EPL L F4000EPL CA Wiring D iagram...

Страница 33: ...Opener 900 2400 Clothes Dryer Electrical 5400 1350 Curling Iron 1500 0 Iron 1100 0 Hair Dryer 1200 Watt 1200 0 Washing Machine 1000 3000 Security System 550 0 Air Compressor 1 3 HP 300 780 Quartz Hal...

Страница 34: ...ting Watts Required 250 For this Example a Generator with a minimum of ___2175___ Total Running Watts and ___2425___ Total Starting Watts is required I Require a Generator with a minimum of __________...

Страница 35: ...LC will repair or replace at its option any part that is proven to be defective in material or workmanship under normal usage Repairs and or replacement will be made without charge for parts or labor...

Страница 36: ...tion is based on the latest product information available at the time of approval for printing We reserve the right to make changes at any time without notice and without incurring any obligation The...

Страница 37: ...h e t i m e o f a p p r o v a l f o r p r i n t i n g We r e s e r v e t h e r i g h t t o m a k e c h a n g e s a t a n y t i m e w i t h o u t n o t i c e a n d w i t h o u t i n c u r r i n g a n y...

Отзывы: