CAUTION:
If cannot restart the engine, check the engine oil level first before go to other check items.
Ⅱ
.Breaker
The breaker which protect the charging circuit of the battery will cut off automatically in the case that short circuit
or incorrect connection of the battery poles occurs.
The green indicator in the breaker will jump out with the circuit cutting off. After finding troubles and
troubleshooting, depress the breaker button to turn the breaker on.
Ⅲ
. Operating on highlands
On highlands, the standard mixture ratio is relatively too big so the engine performance may be impaired while the
fuel consumption may increase, besides, too big mixture ratio will pollute the spark plug and result in starting the
engine difficultly. This problem can be solved by amending the carburetor technological status. If always using on
highlands with at 1800 meters above sea level, ask your dealer for help.
However, the engine power will decrease by about 3.5% with every 305 meters up in height.
CAUTION:
Amended engine applicable to highlands may be damaged seriously in area below altitude of 1800 meters for
overheating, because its mixture ratio is too small for operation in low altitude area. In the case, ask your dealer to
recover the engine to its normal technical status.