10. Route power supply cords so they are not walked on or pinched.
11. Never block or insert any object into the ventilation holes or other openings. 

Maintain a clearance of four (4) inches in front and rear of the UPS for

proper air flow and cooling.

12. Always turn off the UPS and unplug it before starting the battery

replacement procedure.  Servicing of batteries should be performed or

supervised by personnel knowledgeable of batteries and the required

precautions.  To replace batteries, refer to the battery replacement

procedure.  If you feel unqualified to replace the batteries, do not open the 

battery door.  Refer all servicing to qualified service personnel.

13.

CAUTION:

  Do not open or mutilate the batteries.  Released electrolyte is 

harmful to skin and eyes and may be toxic.

INTRODUCTION AND SYSTEM DESCRIPTION

Congratulations on your choice of the Liebert UPStation GXT™ Uninterruptible 

Power System (UPS).  It provides conditioned power to microcomputers and

other sensitive electronic equipment.

Upon generation, AC power is clean and stable.  However, during transmission 

and distribution it may be subject to voltage sags, spikes, or complete power

failure which may interrupt computer operations, cause data loss, or even

damage equipment.  The UPStation GXT™ protects equipment from these

disturbances.

The UPStation GXT™ comes in nominal power ratings of 700, 1000, 1500, 2000, 

or 3000 VA.  Complete specifications appear near the end of this section.

The UPStation GXT™ is a compact, “on-line” UPS.  An “on-line” UPS

continuously conditions and regulates its output voltage, whether the utility power 

is present or not.  It supplies connected equipment with clean sinewave power.

Sensitive electronic equipment operates best from sinewave power.

For ease of use, the UPStation GXT™ contains a light emitting diode (LED)

display to indicate either “load percentage” or “battery capacity” depending upon 

the mode of operation.  It also provides self-diagnostics, a combination On/Alarm 

Silence/Manual Battery Test button, a combination Off/Bypass button, and two 

levels of alarms when the unit is operating on battery.

The UPStation GXT™ has an interface port for communications between the

UPS and a LAN server or other computer system.  This port provides detailed 

operating information including voltages, currents, and alarm status to the host 

system when used in conjunction with Liebert SiteNet® software.  SiteNet®

software can also remotely control UPS operation.

CAUTION: This equipment has been tested and complies with limits for a Class 

A digital device, pursuant to Subpart B of Part 15 of FCC rules.  These limits

provide reasonable protection against harmful interference when the equipment 

is operated in a commercial environment.  This equipment generates, uses, and 

can radiate radio frequency energy.  If it is not installed and used in accordance 

with the instruction manual, it may cause harmful interference to radio

communications.  Operation of this equipment in a residential area is likely to

cause harmful interference which the user must correct at his own expense.

DISCONTINUED 

PRODUCT

Содержание UPStation GXT1000MT-120

Страница 1: ...POWER PROTECTION USER MANUAL English Espa ol R 700 3000 VA 120V UPStation GXT DISCONTINUED PRODUCT...

Страница 2: ...POSAL OF BATTERIES IS REQUIRED REFER TO YOUR LOCAL CODES FOR DISPOSAL REQUIREMENTS POUR LE REMPLACEMENT UTILISER LE M ME NOMBRE ET TYPE DE BATTERIES L LIMINATION DES BATTERIES EST R GLE MENT E CONSULT...

Страница 3: ...s section The UPStation GXT is a compact on line UPS An on line UPS continuously conditions and regulates its output voltage whether the utility power is present or not It supplies connected equipment...

Страница 4: ...inewave input current achieves two objectives the utility power is used as efficiently as possible by the UPS and the amount of distortion reflected on the utility is reduced This results in cleaner p...

Страница 5: ...the rack tower RT models For battery run times refer to the Typical Battery Discharge Curves DYNAMIC BYPASS The UPStation GXT provides an alternate path for utility power to the connected load in the...

Страница 6: ...or 1500 VA units a 20 amp device for the 2000 VA unit and a 30 amp device for the 3000 VA unit The wall receptacle must be grounded 6 Locate the UPS indoors in a controlled environment where it cannot...

Страница 7: ...ight side and remove the six rubber feet with the screw driver Remove and retain screws from the two front feet NOTE The rubber feet are not used for rack mount installations 6 Locate securing flanges...

Страница 8: ...the connected load equipment The UPS is ready for normal operation OPTIONAL BATTERY CABINET S INSTALLATION Up to two optional battery cabinets may be connected to the UPS to provide additional run ti...

Страница 9: ...e bead so that the ferrite bead s case snaps closed with the cable routed inside the ferrite bead s case SNMP Installation Attach the larger enclosed ferrite bead clamp to the network cable as shown i...

Страница 10: ...oad Battery Level Indicators 700 1000 VA Mini Tower 1000 1500 VA Rack Tower 2000 VA Rack Tower 3000 VA Rack Tower 2 6 4 5 3 1 1 6 2 4 6 6 2 2 4 4 3 5 7 5 7 7 5 1 3 5 3 3 1 Output Receptacles 2 DB 9 In...

Страница 11: ...result in loss of power to the output sockets and connected loads Perform all necessary shutdown procedures on connected loads before pressing this button twice Load Battery Level Indicators 4 Green 1...

Страница 12: ...both switches up 110 VAC first switch up second down 120 VAC both switches down Factory Default 127 VAC first switch down second up NOTE Setting output voltage to 100 VAC will cause UPS unit to be de...

Страница 13: ...indicators remain illuminated Refer to the Troubleshooting Guide For battery run times refer to the Typical Battery Discharge Curves To increase this time turn off non essential pieces of equipment s...

Страница 14: ...Station GXT UPS has the capability of being monitored with stand alone computers network workstations network servers or UNIX hosts via the DB 9 female connector located on the rear of the UPS This ca...

Страница 15: ...l internal Ethernet SNMP card Optional SiteNet SNMP Manager software is available to allow communication through several network management systems Contact your local Liebert representative dealer or...

Страница 16: ...ated at the end of this section MINI TOWER BATTERY REPLACEMENT Battery connector Battery door screws FOR 700 1000 VA MINI TOWER MODELS 1 Gently lay the UPS on its right side 2 Loosen and remove the fi...

Страница 17: ...ttery door Remove the door by pulling it forward and lifting it off Lay aside for reassembly 4 Pull battery assembly out approximately 50mm 2 in Gently pull the battery wiring out and disconnect the b...

Страница 18: ...battery door Battery connector Large battery door Screw hidden by small battery door Small battery door Two front rubber feet Front bezel cover Rear View Aerial View w top cover removed Flange screws...

Страница 19: ...N A 479 554 408 343 273 20 N A N A 255 337 215 204 140 30 N A N A 150 212 125 133 78 40 N A N A 110 154 95 100 57 50 N A N A 85 116 75 77 44 60 N A N A 66 89 57 60 35 70 N A N A 56 73 48 50 30 80 N A...

Страница 20: ...s into position 5 Reconnect the input power lead to the UPS and the input power lead to the input AC supply 6 Restart the UPS The UPS is ready for normal operation NOTE For 2000 VA units press the res...

Страница 21: ...ass due to output overload beep every half second A On bypass due to over temperature condition beep every 4 seconds B On bypass due to DC bus overvoltage beep every 4 seconds C On bypass due to contr...

Страница 22: ...y and remove non essential loads Recalculate load VA and reduce number of loads connected to UPS Check load equipment for faults Fault and Bypass indicators and diagnostic LED A are illuminated UPS in...

Страница 23: ...eptacles 4 NEMA 5 15R 4 NEMA 5 15R Voltage 100 110 120 127 switch selectable VAC 3 Frequency 50 Hz or 60Hz Waveform Sinewave Main Mode Overload 200 for 8 cycles 130 for 10 seconds with transfer to byp...

Страница 24: ...NEMA 5 15R Voltage 100 110 120 127 switch selectable VAC 3 Frequency 50 Hz or 60Hz Waveform Sinewave Main Mode Overload 200 for 8 cycles 130 for 10 seconds with transfer to bypass BATTERY PARAMETERS T...

Страница 25: ...6 ft detached w NEMA L5 30 plug OUTPUT AC PARAMETERS Output Receptacles 8 NEMA 5 15R 6 NEMA 5 15R 2 NEMA 5 20R 6 NEMA 5 15R 1 NEMA L5 30R Voltage 100 110 120 127 switch selectable VAC 3 Frequency 50 H...

Страница 26: ...oltage x Batt Rating 2x3x12Vx7 0 or 7 2 AH 2x4x12Vx7 0 or 7 2 AH 1x8x12Vx7 0 or 7 2 AH Batt Mfg Part CSB GP1270F2 or Panasonic LC R127R2CH1 Back up Time See Typical Battery Discharge Curves Recharge T...

Страница 27: ...ed modification alteration or repair use beyond rated capacity or improper installation maintenance application or use including without limitation use in a manner contrary to the accompanying instruc...

Страница 28: ...to more than 1000 kVA Integrated systems that provide both environmental and power protection in a single flexible package Monitoring and control on site or remote from systems of any size or location...

Отзывы: