INT-66HDX
Installation Guide
30
Description
Command
Response
Factory Reset
%0911.
Factory Default
Power On RS232 Routing to HDBaseT
Power Off RS232 Routing to HDBaseT
Factory Reset
The factory reset command will reset every setting to the factory defaults. EDID, HDCP, routing, presets, IP address,
web GUI customization, and more will all be reset to the original settings. Use extreme caution when the matrix is
used in a live environment.
In addition to immediate transmission, the INT-66HDX can store commands to be broadcast when the matrix is
powered on through the standby commands (
PWON.
,
STANBY.
,
and
PWOFF.
).
The format of the RS232 routing string is:
/+<Y>/<B>:<$>.
(The period at the end of the string is required.)
<Y>
is the output code,
<B>
is the baud rate, and
<$>
is the RS232 string. Output codes and baud rate codes are
in the tables below.
In addition to immediate transmission, the INT-66HDX can store commands to be broadcast when the matrix is
powered off through the standby commands (
PWON.
,
STANBY.
,
and
PWOFF.
).
The format of the RS232 routing string is:
/+<Y>/<B>:<$>.
(The period at the end of the string is required.)
<Y>
is the output code,
<B>
is the baud rate, and
<$>
is the RS232 string. Output codes and baud rate codes are
in the tables below.
Baud
Baud Code
2400
1
4800
2
9600
3
19200
4
38400
5
57600
6
115200
7
Baud
Baud Code
2400
1
4800
2
9600
3
19200
4
38400
5
57600
6
115200
7
HDBaseT Port
Port Code
Output 1
A
Output 2
B
Output 3
C
Output 4
D
Output 5
E
Output 6
F
HDBaseT Port
Port Code
Output 1
G
Output 2
H
Output 3
I
Output 4
J
Output 5
K
Output 6
L
Содержание intelix INT-66HDX