AS-1H1V Installation Guide
10
Contact Closure Inputs
The AS-1H1V includes dry contact closure inputs to allow different types of manual switching. These contact closure
inputs are intended to be connected directly to relays or switches. To activate, simply short the associated terminal
to the “GND” terminal. Normally open, momentary switches should be used.
The AS-1H1V ships from the factory with a jumper in place between the “AUTO”, and “GND” terminals; this should
remain in place if you wish the unit to switch automatically when a video signal is present.
Default Mode - Auto-Switching
Manual Switching
Auto-Switching with Manual Override
Gnd
Auto
HDMI
VGA
Gnd
Auto
HDMI
VGA
Gnd
Auto
HDMI
VGA